• 제목/요약/키워드: sound-pressure-level(SPL)

검색결과 127건 처리시간 0.135초

Acoustic Characteristic of Emergency Broadcasting Speakers (비상방송용 스피커의 음향 특성 비교)

  • Jeong, Jeong-Ho;Seo, Bo-Youl;Park, Kye-Won;Shin, Yi-Chul;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • 제33권1호
    • /
    • pp.130-137
    • /
    • 2019
  • In this study, the acoustic characteristics of 13 types of emergency broadcasting speakers were tested under the test set-up of UL 2043 and compared. When the sound pressure level of 1 W speakers was compared with speakers with a 15 W output, the SPL of the 15 W speakers was approximately 20 dB higher in some frequency bands. Loudness analysis showed that people can recognize emergency sound from a 15 W speaker twice as loud as the emergency sound from 1 W speakers. The analysis results on the articulation index (room) had an opposite tendency with loudness results, meaning that small speakers can generate clearer sound. Therefore, it is necessary to improve emergency broadcasting speakers to generate louder and clearer sound. Moreover, a performance evaluation standard is needed based on the reasonable and quantitative measurements and evaluations of the acoustic characteristics of the emergency-broadcasting speakers so that a sufficient and clear sound can be generated in various spaces. In addition, it is necessary to establish standards for the clarity of emergency broadcasting in various spaces.

Active control of pump noise of dishwashers using FxLMS algorithm (FxLMS 알고리듬 기법을 이용한 식기 세척기의 펌프 소음 능동 제어)

  • Tark, Un-su;Oh, Han-Eum;Hong, Chinsuk;Jeong, Weui-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • 제40권1호
    • /
    • pp.46-54
    • /
    • 2021
  • In this paper, active noise control was performed to reduce radiated noise in the low frequency band of dishwashers. First, through an analysis of the noise environment of the dishwasher, it was confirmed that the pump noise contributed the most to the radiated noise in the low frequency band, From the result of the noise environment analysis, the reference signal was selected to be the vibration signal of the pump body. The reference signal was obtained by using the accelerometer on the pump body, which can prevent acoustic feedback. The error signal sensor was selected as a microphone located at 1 m in front of the dishwasher and 0.5 m in height. And to design the controller, the error signal and the reference signal were measured at the operational rpms of the dishwasher at 2,500 rpm, 2,600 rpm and 2,800 rpm, and the secondary path transfer function was measured. The designed controller was mounted on Digital Signal Processor (DSP) equipment, and the control performance was verified experimentally. As a result of the measurement at the 3 operational rpms, the 7th multiple component of pump operating frequency decreased by 1.93 dB, 4.43 dB, 5.15 dB per rpm, and the 12th multiple component decreased by 6.67 dB, 2.34 dB, 4.28 dB per rpm. And overall Sound Pressure Level (SPL) decreased by 0.84 dB, 2.58 dB, 1.48 dB by rpm.

Effect of acoustic wave on the evaporation/combustion of suspended droplet (음파가 고정액적의 증발/연소에 미치는 영향에 관한 연구)

  • Han, Jae-Seob;Kim, Seon-Jin;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제6권3호
    • /
    • pp.53-60
    • /
    • 2002
  • This paper presents the results of the experimental investigation on the effect of acoustic wave on the combustion of suspended A-1 jet fuel droplets in atmospheric pressure. Experimental results indicate that A-1 jet fuel droplet burning rate constants $k_c$ were independent of initial droplet size and the relative evaporation/burning-rate constant $k_{e'}k_c$(ratio of the acoustically disturbed evaporation/burning-rate constant to the undisturbed evaporation/burning-rate constant) increased remarkably 1.2~1.51times, 1.04~1.42times, for frequency below 100Hz, and sound pressure level above 80dB.

An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients (구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구)

  • Ahn, Tae-Sub;Yang, Sang-Ill;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • 제1권
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

Parametric Array Signal Generating System using Transducer Array (트랜스듀서 배열을 이용한 파라메트릭 배열 신호 생성 시스템)

  • Lee, Jaeil;Lee, Chong Hyun;Bae, Jinho;Paeng, Dong-Guk;Choe, Mi Heung;Kim, Won-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • 제32권4호
    • /
    • pp.287-293
    • /
    • 2013
  • We present a parametric array signal generating system using $3{\times}16$ transducer array which is composed of multi-resonant frequency transducers of 20kHz and 32.5kHz. To drive transducer array, sixteen channel amplifier using LM1875 chips is designed and implemented, and the PXI system based on the LabView 8.6 for arbitrary signal generation and analysis is used. Using the proposed system, we measure sound pressure level and beam pattern of difference frequency and verify the nonlinear effect of difference frequency. The theoretical absorption range and the Rayleigh distance are 15.51m and 1.933m, respectively and we verify that sound pressure of difference frequency is accumulated and increased at the near-field shorter than the Rayleigh distance. We verify that the beam pattern of the measured difference frequency and the beam pattern obtained by the superposition of two primary frequencies are similar, and high directional parametric signal was generated.

Evaluation on Riding comfort of A Passenger with Various Surface Textures of Concrete Pavement in Tunnels (터널 내 콘크리트포장 표면처리공법 별 탑승자의 주행쾌적성 평가)

  • Lee, Kyungbae;Lee, Jaehoon;Sohn, Duecksu;Kwon, Soonmin
    • International Journal of Highway Engineering
    • /
    • 제16권5호
    • /
    • pp.155-164
    • /
    • 2014
  • PURPOSES : The purpose of this article is to compare and evaluate the riding comfort of a passenger in tunnels depending on different surface textures of concrete pavement. METHODS : Evaluation of riding comfort is conducted at 17 sections, which have different surface texture such as transverse tinned(TT), longitudinal tinned(LT) and diamond grinded(DG). A triaxial accelerometer was set up on the passenger seat surface of the test vehicle to measure vibrations of an occupant, then the effects of vibration on comfort and health were evaluated by ISO 2631. And microphones were installed at passenger's ears height to measure sound pressure level(SPL) in the test vehicle. Additionally, a surface microphone was installed on the inside of wheel arch to evaluate noise between tire and pavement by NCPX method. All tests were conducted cruising at 100km/h. RESULTS : The results of all tests are as follows. First, both vibration magnitudes for comfort and for health in LT and DG sections are almost same and they represent lower than those in TT sections. Second, the average SPL of DG shows the lowest decibels among them. And third, it is founded that interior noise is significantly affected by noise between tire and pavement. CONCLUSIONS : It may be concluded that DG can provide more excellent riding comfort to passenger than LT or TT. Therefore, it is necessary to consider applying DG to existing pavement surface to improve surface condition when the driving environment especially requires riding comfort like a long tunnel.

Combinational flexible OLED display device using piezoelectric polymer PVDF (압전폴리머 PVDF를 이용한 복합형 유연 OLED 디스플레이 소자)

  • Le, Sang-Yub;Bea, Byung-Tack;Park, Dong-Hee;Choi, Ji-Won;Choi, Won-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.55-55
    • /
    • 2008
  • 압전폴리머 PVDF(polyvinylidene difluoride)의 기판소재를 기반으로 한 디스플레이 소자를 연구하였다. 압전 폴리머 PVDF의 양면은 두께 300nm정도의 ITO(Indium Tin Oxide)를 TCO(Transparent conducting oxide)로 R2R(roll to roll)증착하였으며, 이를 적외선 계열 Pulsed Laser로 상온 건식 에칭을 통해 패턴해내고, 이후 고진공 환경에서 Alq3 를 기반의 유기발광소자를 제작하였다. 전기적 신호에 대해서 기계적인 작동이 가능한 투명 압전 폴리머 재료를 디스플레이 발광소자의 기판 소재로 사용함으로써, 궁극적으로 발광기능과 더불어 압전효과에 의한 스피커 기능이 한 개의 개체내에서 독립적으로 구현될 수 있도록 설계하고, 기술적으로 실현시켰다는 점이 본 연구의 의의라고 할 수 있다. 이를 위해서, 섭씨 80도 이상의 온도에서 압전 성질을 상실하는 것으로 알려진 PVDF에 대해서 투명산화전극을 레이져를 이용한 비가열식 승화방법을 통해 패턴화하는 것을 사용했으며, 밀리미터 단위에서 수십 마이크로미터 수준까지 패턴화할 수 있었다. 제작된 복합형 유연 OLED소자는 기계적으로 휘어진 상태에서도 발광 성능과 스피커 성능을 각각 독립적으로 보였으며, Alq3에 의한 녹색발광을 보임을 확인하였고, 이 경우 양자효율은 약 3%이하의 값을 보였다. 또한 각주파수별 음압(SPL: Sound Pressure Level)측정 결과는 압번폴리머가 가청주파수 영역에서 작동함을 보였으며, 고주파영역에서의 SPL값이 증가하는 전형적인 PVDF사용 필름 스피커의 특성을 보였다. 이로부터 제작된 복합형 소자는 본 연구에서 제안된 목적에서 보인 것과 같이, 두 개의 기능이 서로간의 간섭없이 독립적으로 한 개의 개체 내에서 작동함을 확인할 수 있었다. 본 연구 결과로부터 새로운 유연 전자 소자에 대한 디자인 개념을 제시하고, 기타 다른 기능이 접합된 형태의 신개념 전자 소자를 제안하는 것도 가능할 것으로 기대된다.

  • PDF

Characteristics and Fabrication of Multi-Layered Piezoelectric Ceramic Actuators for Speaker Application (스피커 응용을 위한 적층형 압전 세라믹 액츄에이터 제조 및 특성)

  • Lee, Min-seon;Yun, Ji-sun;Park, Woon Ik;Hong, Youn-Woo;Paik, Jong Hoo;Cho, Jeong Ho;Park, Yong-Ho;Jeong, Young-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제29권10호
    • /
    • pp.601-607
    • /
    • 2016
  • Piezoelectric thick films of soft $Pb(Zr,Ti)O_3$ (PZT) based commercial material (S55) were fabricated using a conventional tape casting method. Ag-Pd electrodes were printed on the piezoelectric film at room temperature and all 5 layered films with a dimension of $12mm{\times}16mm$ were successfully laminated for a multi-layered piezoelectric ceramic actuator. The laminated specimens were co-fired at $1,100^{\circ}C$ for 1 h. A flat layered and dense microstructure was obtained for the $112{\mu}m$ thick piezoelectric actuator after sintering process. Thereafter, a prototype piezoelectric speaker was fabricated using the multi-layered piezoelectric ceramic actuator which can operate as a bimorph. Its SPL (sound pressure level) characteristic was also evaluated for speaker application. Frequency response revealed that the output SPL with a root mean square voltage of 10 V increased gradually to the highest peak of 87.5 dB for 1.5 kHz and exhibited a relatively stable behavior over the measured frequency range (${\leq}20kHz$) at a distance of 10 cm, implying that the fabricated piezoelectric speaker is potential for speaker applications.

Design and Construction of the Acoustic Horn for Magnetostrictive Ultrasonic Transducer (자왜형 초음파 트랜스듀서용 도파봉의 설계 및 제작)

  • 강국진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.57-65
    • /
    • 2001
  • In this paper, we designed the acoustic horn for magnetostrictive ultrasonic transducers in a theoretical manner, and validity of the analysis was verified through comparison with the results of finite element analysis. Results of the two analysis methods showed good agreement with each other. The theoretical method can fairly quickly determine the horn length that satisfies given frequency specification, but also has the drawback that it is applicable only to the frequency range over the cut-off frequency. According to the results, the catenoidal horn can provide larger amplification than the exponential horn. It was also found that it is more desirable for the region having the catenoidal curvature to be as short as possible to achieve larger amplification of the transducer deformation. Based on the analysis results, a magneto-strictive transducer sample was fabricated and its performance was evaluated experimentally. The transducer has the resonance frequency of 19.3 ㎑ as well as the maximum SPL of 199 dB, and shows the omni-directional radiation pattern.

  • PDF

Study of Optimum Operating Conditions of Thermal Acoustic Generator (열음향파 발생장치의 최적 작동 조건에 대한 실험적 연구)

  • Shin, Sang Woong;Oh, Seung Jin;Lee, Yoon Joon;Kim, Nam Jin;Chun, Wongee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제37권2호
    • /
    • pp.131-137
    • /
    • 2013
  • This study deals with the effects of major geometric parameters on the sound wave output of a thermal acoustic system. The output power of the acoustic wave was dependent on the stack position, stack length, resonator tube length, and input power. In experiments, the maximum SPL was generated when the stack was placed between one-fourth to half, resonator and stack length were longer, and input power was increased. The frequency was recorded to be 437 and 885 Hz when the resonator tube length was 200 and 100 mm, respectively. Therefore, when the resonator tube length was shorter, a higher frequency was recorded.