• 제목/요약/키워드: sound wall

검색결과 309건 처리시간 0.027초

FXLMS 알고리듬을 이용한 덕트의 능동소음제어 (Active Noise Control of Ducts Using the FXLMS Algorithms)

  • 류경완;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.489-496
    • /
    • 2008
  • This paper investigates active noise control of ducts using Filtered-x Least Mean Square (FXLMS) algorithms to reduce noise transmission. Single channel FXLMS (MFXLSM) and multiple channel FXLMS (MFXLMS) algorithms are used to implement the active control systems. The transmission loss is significantly increased by SFXLMS but the sound pressure level (SPL) at the upstream of the error sensor is increased while that of downstream is very low. This increase of the upstream SPL causes the duct wall to vibrate and so to radiate noise. To prevent the wall vibration generated by the sound field upstream, global sound field control is required. To reduce SPL globally along the duct, active noise control using MFXLMS is implemented. We can then obtained globally reduced SPL. It is found experimentally that the vibration level, and so the radiated noise level. can be reduced by the active noise control using MFXLMS.

  • PDF

Numerical Investigation on the Characteristics of Flow-Induced Noise in a Centrifugal Blower

  • Lee, Chanyoung;Jeong, Taebin;Ha, Kyoung-Ku;Kang, Shin-Hyoung
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권1호
    • /
    • pp.7-15
    • /
    • 2014
  • In the present study, a computational analysis of the flow in a centrifugal blower is carried out to predict a performance and to explain noise characteristics of the blower. Unsteady, 3D Navier-Stokes equations were solved with k-${\varepsilon}$ turbulence model using CFX software. CFD results were compared with the experimental data that is acquired from an experiment conducted with the same blower. The pressure fluctuation in the blower was transformed into the frequency domain by Fourier decomposition to find the relationship between flow behaviors and noise characteristics. Sound pressure level (SPL) which is obtained from wall pressure fluctuation at impeller outlet represents relative overall sound level of the blower well. Sound spectra show that there are some specific peak frequencies at each mass flow rate and it can be explained by flow pattern.

FXLMS 알고리듬을 이용한 덕트의 능동소음제어 (Active Noise Control of Ducts Using the FXLMS Algorithms)

  • 류경완;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제19권1호
    • /
    • pp.24-34
    • /
    • 2009
  • This paper investigates active noise control of ducts using filtered-x least mean square(FXLMS) algorithms to reduce noise transmission. Single channel FXLMS(SFXLSM) and multiple channel FXLMS(MFXLMS) algorithms are used to implement the active control systems. The transmission loss is significantly increased by SFXLMS but the sound pressure level(SPL) at the upstream of the error sensor is increased while that of downstream is very low. This increase of the upstream SPL causes the duct wall to vibrate and so to radiate noise. To prevent the wall vibration generated by the sound field upstream, global sound field control is required. To reduce SPL globally along the duct, active noise control using MFXLMS is implemented. We can then be obtained globally reduced SPL. It is found experimentally that the vibration level, and so the radiated noise level, can be reduced by the active noise control using MFXLMS.

정상상태조건에서의 개구부로 연결된 커플룸의 음향 특성 (Room Acoustic Properties of Coupled Rooms Connected by an Aperture in the Steady State Condition)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.315-322
    • /
    • 2016
  • Room acoustic properties of coupled rooms connected by an aperture has been analyzed using statistical acoustic model based on the diffused sound field assumption, which has limitation in dealing with the parameters such an room geometries and non uniform absorptivity of the boundary surfaces. In order to overcome these difficulties the acoustic diffusion model has been introduced, by which distribution of the acoustic energy density can be analyzed for various shapes and wall absorptivity. In this study acoustic properties of coupled rooms connected by an aperture(e.g. door) is analyzed using acoustic diffusion equation, which is solved numerically. The mean energy densities of two rooms obtained by the diffusion model are compared with those from the statistical model. The results show good agreement for various coupling aperture sizes and absorption coefficients. For a limiting case when the partition wall is substituted by an aperture and the two rooms eventually forms a single room, results of coupled room analysis using diffusion model show good agreement with those of a single room.

공동주택의 소음성능 실측평가에 관한 연구 (A Study on the Sound Insulation performance Survey Estimation in Apartment house)

  • 함진식;박명길
    • 한국주거학회논문집
    • /
    • 제12권4호
    • /
    • pp.219-226
    • /
    • 2001
  • This treatise measures and estimate sound insulation performance of apartment house. Sound insulation performance measured to the floor and wall. Measurement object is apartment occupancy ago of 100㎡ scale built to higher story in Taegu city. Floor Slav's light impact sound level interception performance interacted by benevolent person who carrying out availability of finish material important. Floor Slav's heavy impact sound level interception performance amounted estimation by being good more or less then light impact sound level interception performance. Because sound insulation performance of partition between adjoined generation is gad seldom, privacy infringement becomes anticipation. There was discussion about these results, and presented various kinds future research task to prove sound insulation performance of apartment house.

  • PDF

차세대 고속철도 차량 측면 적층재의 차음성능 (Sound Insulation Performance of the Side Layered Panels in the Next Generation High Speed Train)

  • 이중혁;이호진;박인석;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.457-462
    • /
    • 2011
  • The sidewall of the HEMU-400x consists of two parts. One is the multi-layered structure including aluminium extruded panel and the other is the double glazed window. When the train runs in a tunnel, the equivalent sound insulation performance of the side wall significantly influences the internal noise levels. In aspect of the sound insulation strategy, it is important to make two parts have similar performance. In this study, the intensity sound transmission loss (ITL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance of the two parts in respect of the weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy is investigated to reduce the interior noise.

  • PDF

Acoustic Power Control of a Lightly-Damped Enclosed Sound Field

  • Kim, Woo-Young;Kim, Dong-Kyu;Hwang, Won-Gul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제2권2호
    • /
    • pp.19-27
    • /
    • 2001
  • This research attempts to find an active control strategy which reduces acoustic power and acoustic energy in lightly-damped enclosed sound field such as a vehicle compartment or an operating room of heavy industrial machinery. An active control strategy, which takes into consideration of the acoustic radiation power of the source as a cost function, is formulated and examined to find capability of reducing noise. An adaptive filtering algorithm for sound power control is suggested and implemented to control lightly-damped sound field. To verify the method, sound power based active noise control algorithm was implemented on a rectangular box with lightly-damped wall, and popular acoustic energy based control with modal coupling reduction was performed to compare the noise reduction performance. It was shown that a total sound power based strategy provides a practical mean for global noise reduction for lightly damped sound field.

  • PDF

틸팅열차 측면재의 차음 전략 (Sound Insulation Strategy of the Side Panels in a Tilting Train)

  • 김석현;서태건
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.33-38
    • /
    • 2011
  • In an express tilting train, side wall insulating the noise from the exterior sound source consists of two parts. One is the layered composite panel including aluminum honeycomb, glass wool and nomex honeycomb. The other is the double glazed window. In this study, sound insulation performance of the two parts is investigated by mass law and experiment. Based on ASTM E2249-02, the intensity sound transmission loss (TL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance in respect of weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy for the interior noise reduction is investigated.

  • PDF

축소모형법을 이용한 흡음재와 확산체 배치조건별 교실의 음향성능 측정 및 평가 (The Measurements and Evaluations on the Configurations of Absorptive and Diffusing Treatments in Classrooms using a Scale Model)

  • 최영지
    • 교육시설 논문지
    • /
    • 제20권1호
    • /
    • pp.37-44
    • /
    • 2013
  • The present study examines the effects of periodic type diffusers for producing the preferred acoustics for speech and determines the more successful configurations of sound-absorbing and diffusing treatments for achieving good acoustics in classrooms. The measurements were carried out in a 1/10 scale model classroom systematically adding diffusers to one or more of four surfaces of the room. A total of 13 combination of diffusers with absorptive treatments were investigated. Adding diffusers on the ceiling were more effective to increasing the early-arriving reflection energy($G_{50}$) than adding absorptive materials on the entire ceiling. The late arriving reflection energy($G_{late}$) was decreased with increasing amounts of diffusing treatments of upper front or rear wall and this resulted in achieving higher early-to-late ratios($G_{50}$). Adding diffusers on the upper front wall($AC_{100}DUFW_{26}$) achieved more uniform acoustical conditions over the receiver positions than adding diffusers on the upper rear wall($AC_{100}DUFW_{26}$). Adding diffusers on the ceiling and absorptive materials on the lower front wall($AC_{75}DC_{25}ALFW_{26}$) achieved better acoustical conditions than adding the absorptive materials on the entire ceiling and lower front wall($AC_{100}ALFW_{26}$).

Enhancement of Sound Clarity of Classrooms Using Sound Diffusers and Panel Absorbers

  • Shin, Sang-Bong;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권2E호
    • /
    • pp.60-65
    • /
    • 2009
  • The present study aims to investigate the effects of sound diffusers and absorbers on the sound clarity in classrooms. In order to do this, computer simulations were carried out to find the effective area of treatment which could enhance the sound clarity in the room. Acoustic measurements were undertaken in a lecture room with several conditions changing the surface of walls and ceilings with diffusers and absorbers. Diffusion and absorption treatments were applied to the side walls, rear wall and the ceiling of the classroom. SPL, RT, D50, RASTI were measured at 9 measurement points with one sound source and MLS was used as the sound source signal. The results show that higher sound clarity was obtained when diffusers were applied to rear walls and ceiling rather than side walls. Also, it was confirmed that absorption increased sound clarity more effectively with smaller amount in comparison with diffusers. It was also concluded that the effects of sound diffusers and absorbers on the sound clarity could be obtained distinctly at the rear area of the classroom.