• 제목/요약/키워드: soot 입자

검색결과 125건 처리시간 0.023초

엔진 배기단 적용을 위한 Time Resolved Laser Induced Icandescence (TIRE-LII) 신호의 보정 : 카본 입자 이용 (The Calibration Method of Time Resolved Laser Induced Incandescence Using Carbon Black Particles for the Soot Measurement at Exhaust Tail Pipe in Engine)

  • 오광철;김덕진;이천환;이춘범
    • 대한기계학회논문집B
    • /
    • 제29권12호
    • /
    • pp.1335-1343
    • /
    • 2005
  • The calibration technique of Time Resolved Laser Induced Incandescence was investigated both experimentally and numerically by using standard-sized carbon black particles for the instantaneous soot measurement at exhaust tail pipe in engine. The carbon black particles (19nm, 25nm, 45nm and 58nm) used in this study are similar, though not identical, to soot particle generated from flame not only in morphology but also in micro-structure. The amount of soot loading in flow was controled by a diluted gas (nitrogen) and was measured by the gravimetric method at exhaust pipe in calibrator. The successful calibrations of primary particle size and soot mass fraction were carried out at the range from 19nm to 58nm and from $0.25mg/m^3$ to $37mg/m^3$ respectively. And based on these results the numerical simulation of LII signal was tuned and the effect of an exhaust temperature variation on the decay rate of LII signal was corrected.

DC 코로나 방전이 적용된 에틸렌 정상 확산 화염의 Soot 배출 저감 (Reduction of Soot Emitted from a $C_2$$H_4$ Normal Diffusion Flame with Application of DC Corona Discharge)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.496-506
    • /
    • 2001
  • The effect of corona discharge on soot emission was experimentally investigated. Size and number concentrations of soot aggregates were measured and compared for various voltages. Regardless of the polarity of the applied voltage, the flame length decreased and the tip of flame spreaded with increasing voltage. For the experimental conditions selected, the flame was blown off toward the ground electrode by corona ionic wind. When the negative applied voltage was greater than 3kV(for electrode spacing = 3.5cm), soot particles in inception or growth region were affected by the corona discharge, resulting in the reduction of number concentration. The results show that the ionic wind favored soot oxidation and increased flame temperature. Number concentration and primary particle size greatly increased, when the corona electrodes were located the region of soot nucleation or growth(close to burner mouth).

열영동 포집 방법을 이용한 층류 확산 화염내의 매연입자 크기측정 (Soot Size Measurement in a Laminar Diffusion Flame Using Thermophoretic Sampling Technique)

  • 전지호;김상수
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1697-1705
    • /
    • 1991
  • 본 연구에서는 층류 확산화염내의 매연 분포에 관하여 좀 더 명확히 알아보고 자 화염의 높이방향 뿐만이 아니라 반경 방향으로도 매연을 열영동 포집하여 보았다. 한편, 화염 내에 삽입되는 Fig.1(a)와 같은 프로브에 매연 입자들이 열영동 현상에 의 하여 포집되려면 순간적인 돈도 구배가 필요하다. 따라서 화염내에서의 프로브 체류 시간을 조절할 수 있도록 Fig.1(b)와 같은 공압 장치(pneumatic device)를 만들어 실 험했다.

DPF내 포집된 입자상 물질의 산화율 산출을 위한 실험적 연구 (Experimental Study on Estimation of Oxidation Rate of PM inside of Diesel Particulate Filter)

  • 심범주;박경석;조규희;이형준;민병두
    • 한국자동차공학회논문집
    • /
    • 제21권2호
    • /
    • pp.98-103
    • /
    • 2013
  • Conventional method to estimate mass of particulate matter accumulated in diesel particulate filter is to use pressure difference between upstream and downstream of the filter. Then measured pressure difference should be compared that of clean condition which is no particulate matter accumulated in DPF. During regeneration soot oxidation is also estimated by same method. This methodology, however, has demerit on accuracy because of pressure difference deviation of clean DPFs and pressure difference caused by non-carbon based PM which is different from that of caused by carbon based PM. This study suggests new methodology to estimate accumulated soot oxidation rate through exhaust gas characteristics during regeneration. Results, more high accuracy of soot oxidation was obtained by analysis of relationship between fuel mass and concentration of carbon dioxide and oxygen.

KIVA3V와 SWEEP을 이용한 디젤 엔진에서의 soot 총량 및 입자 크기 분포 예측 (Prediction of Soot Emissions and Particle Size distribution by KIVA3V and SWEEP in a diesel engine)

  • 이재서;허강열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.129-132
    • /
    • 2012
  • Computation is performed to predict number density, volume fraction and size distribution of soot particles in typical operating conditions of a diesel engine. KIVA has been integrated with the CMC routine to consider turbulence/chemistry coupling and gas phase kinetics for heat release and soot precursors. The compositions of soot precursors are estimated by tracking Lagrangian particles to consider spatial inhomogeneity and differential diffusion in KIVA. The soot simulator SWEEP is employed as a postprocessing step to calculate conditional and integral quantities of soot particles.

  • PDF

레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구 (A Study on the Soot Particle Measurement in Co-Flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple)

  • 한용택;이기형;이원남
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.863-870
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame has been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distribution in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by particles. A laser extinction method was used to measure the soot volume fraction and laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

레이저 및 열전대를 이용한 동축류 확산화염에서의 매연입자 측정에 관한 연구 (A Study on the Soot Particle Measurement in Co-flow Diffusion Flame Using a Laser Diagnostics and a Thermocouple)

  • 한용택;이기형;이원남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1267-1273
    • /
    • 2004
  • The temperature and soot particle measurement technique in a laminar diffusion flame have been studied to investigate the characteristics of soot particle with temperature using a co-flow burner. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple and the soot particles were detected were detected by LEM/LIS techniques. In these measurement, soot volume fraction, number density and soot diameters were analyzed experimentally. As a results, the spacial distributions of particle volume fraction, soot diameter, and number density are mapped throughout the flame using the Rayleigh theory for the scattering of light by absorbing particles. A laser extinction method was used to measure the soot volume fraction and Laser induced scattering method was used to measure the soot particle diameter and number density. Also, we measured temperature without the effect of soot particles attached to the thermocouple junction, which is close to the nozzle. In this result, we found that upstream zone has a unstable flowing in co-flow diffusion flame and the y-axis temperature of flame has a uniform temperature distribution in the most soot volume fraction zone.

  • PDF

원형관 코팅장치에서 연소 입자의 응축성장에 미치는 2차원 열 및 물질전달의 영향 (Effects of Two-dimensional Heat and Mass Transports on Condensational Growth of Soot Particles in a Tubular Coater)

  • 박성훈
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.163-171
    • /
    • 2013
  • Soot particles emitted from combustion processes are often coated by non-absorbing organic materials, which enhance the global warming effect of soot particles. It is of importance to study the condensation characteristics of soot particles experimentally and theoretically to reduce the uncertainty of the climate impact of soot particles. In this study, the condensational growth of soot particles in a tubular coater was modeled by a one-dimensional (1D) plug flow model and a two-dimensional (2D) laminar flow model. The effects of 2D heat and mass transports on the predicted particle growth were investigated. The temperature and coating material vapor concentration distributions in radial direction, which the 1D model could not accounted for, affected substantially the particle growth in the coater. Under the simulated conditions, the differences between the temperatures and vapor concentrations near the wall and at the tube center were large. The neglect of these variations by the 1D model resulted in a large error in modeling the mass transfer and aerosol dynamics occurring in the coater. The 1D model predicted the average temperature and vapor concentration quite accurately but overestimated the average diameter of the growing particles considerably. At the outermost grid, at which condensation begins earliest due to the lowest temperature and saturation vapor concentration, condensing vapor was exhausted rapidly because of the competition between condensations on the wall and on the particle surface, decreasing the growth rate. At the center of the tube, on the other hand, the growth rate was low due to high temperature and saturation vapor concentration. The effects of Brownian diffusion and thermophoresis were not high enough to transport the coating material vapor quickly from the tube center to the wall. The 1D model based on perfect radial mixing could not take into account this phenomenon, resulting in a much higher growth rate than what the 2D model predicted. The result of this study indicates that contrary to a previous report for a thermodenuder, 2D heat and mass transports must be taken into account to model accurately the condensational particle growth in a coater.

TIRE-LII 기법을 이용한 매연 입자 크기에 관한 수치적 연구 (Numerical Investigation on Soot Primary Particle Size Using Time Resolved Laser Induced Incandescence (TIRE-LII))

  • 김정용;이종호;정동수;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1152-1157
    • /
    • 2004
  • Temporal behavior of the laser induced incandescence (LII) signal is often used for soot particle sizing, which is possible because the cooling behavior of a laser heated particle is dependent on the particle size. In present study, LII signals of soot particles are modeled using two non-linear coupled differential equations deduced from the energy- and mass-balance of the process. The objective of this study is to see the effects of particle size, laser fluence on soot temperature characteristics and cooling behavior. Together with this, we focus on validating our simulation code by comparing with other previous results. Results of normalized LII signals obtained from various laser fluence conditions showed a good agreement with that of Dalzell and Sarofim's. It could be found that small particles cool faster at a constant laser fluence. And it also could be observed that vaporization is dominant process of heat loss during first 100ns after laser pulse, then heat conduction played most important role while thermal radiation had little influence all the time.

  • PDF

FHD법에 의해 형성된 실리카 soot의 고밀화 공정에 미치는 온도의 영향 (Effect of Temperature on Consolidation of Silica Soot Prepared by Flame Hydrolysis Deposition)

  • 김성수;유지범;심재기;정며영
    • 한국재료학회지
    • /
    • 제8권4호
    • /
    • pp.337-344
    • /
    • 1998
  • 화염가수분해증착법에 의해 형성된 $0.1\mu\textrm{m}$크기의 soot를 실리콘 기판위에 형성하여 $1325^{\circ}C$에서 2시간 동안 고밀화과정후 투명한 후막을 얻을 수 있었다. 고밀화 열처리는 탈수과정, 재배열 과정, 그리고 고밀화 과정으로 구성되었다. 고밀화 공정후의 두께 수축률은 초기 soot의 96%정도였으며, 급속한 두께의 감소는 $950^{\circ}C$부터 시작되었으며, 본격적인 고밀화가 시작되는 온도는 $1250^{\circ}C$임을 알 수 있었다. soot의 TGA와 DTA를 이용한 열분석 결과 탈수과정에 의하여 9/wt%의 질량감소와 $1250^{\circ}C$이상에서 인(P)의 증발에 의한 2wt%의 질량감소를 관찰하였다. DTA곡선에서는 $500^{\circ}C$, $570^{\circ}C$. $1258^{\circ}C$에서 흡열반응 피크를 나타내는데, 이는 $B_{2}$$O_{3}$, $P_{2}$$O_{5}$ 등의 도펀트들의 melting과 실리카 입자사이의 기공이 소멸되면서 입자간의 열전도도의 증가에 의해 나타난 것으로 판단된다.

  • PDF