• 제목/요약/키워드: solution mixing

검색결과 795건 처리시간 0.03초

액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발 (Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

방사성핵종 오염 토양 특성 분석 및 핵종제거 방법 연구

  • 김계남;원휘준;오원진
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.209-212
    • /
    • 2002
  • Main radionuclides of the soil waste stored in Korea Atomic Energy Research Institute are Co-60 and Cs-137. Moisture content of soil is 12%, pH of soil is 5.8, and content of organic matter is 2.2 %. Radioactive concentrations of the soil particle size of which is less than 0.063mm and soil in the drum surface of which is more than radiation dose rate 0.05mR/hr are higher. Meanwhile, radioactive concentration of soil in the drum surface of which is less than radiation dose rate 0.02 mR/hr are mostly lower. On using the mixing solution of ammonium sulfate and citric acid, 62% Co was removed from soil and 41% Cs was removed. Also, on using the mixing solution of ammonium nitrate and citric acid, 61% Co was removed from soil and 39% Cs was removed, and on using the mixing solution of ammonium potassium oxalate, 36% Co was removed and only 3% Cs was removed. And on using only water, removal efficiency is less than 5%.

  • PDF

용액혼합법에 따른 나노복합재료 분산성 및 전기적 특성 (Dispersibility, Electrical Property of Nano-Composite by Solution Mixing Method)

  • 양훈;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.73-74
    • /
    • 2008
  • In this paper, we have investigated dispersibility, volume resistivity of nano-composite by solution mixing method. Dispersibility measured by FE-SEM(Field Emission Scanning Electron Microscope. And volume resistivity measured by ASTM D991. To expect interaction used dual filler system. But, dual filler system had influence on polymer complex. So, polymer chain mobility doesn't resist.

  • PDF

입구온도가 변화하는 성층축열조의 충전과정 해석 (Analysis on the Charging Process of Stratified Thermal Storage - Tanks with Variable Inlet Temperature)

  • 유호선
    • 태양에너지
    • /
    • 제15권2호
    • /
    • pp.25-37
    • /
    • 1995
  • 유입관성에 의한 유체혼합뿐 아니라 입구온도의 변화까지 고려된 성층축열조의 충전과정 모델에 대하여 해석적 근사해를 제시하였다. 해석모델은 깊이가 일정한 완전혼합 및 압출유동영역으로 구성되며, 입구온도의 변화는 중첩의 원리에 근거하여 계단함수로 근사화하였다. 완전혼합영역의 과도온도를 구한 후 함수형태에 따라 구분하고, 각각을 경계조건으로 하는 압출유동영역의 온도분포를 잘 정의된 함수의 항으로 유도하였다. 결과적으로 이들의 일차결합이 압출유동영역에 대한 최종해이다. 근사해의 타당성 및 결과의 유용성은 입구온도가 선형적으로 증가하는 경우에 대한 엄밀해와의 비교를 통하여 검증하였다. 계단수의 증가에 따라 근사해는 엄밀해로 급속히 접근하며, 유한한 수의 계단에 의한 근사해도 광범위한 혼합깊이에 대하여 엄밀해와 잘 일치한다. 또한, 혼합깊이가 클수록 소수의 계단에 의한 근사해로도 의미있는 예측결과를 얻을 수 있었다.

  • PDF

셀룰로오스/키토산 및 세리신/키토산 복합화필름의 역학특성 (Mechanical Properties of Cellulose/Chitosan and Sericin/Chitosan Blend Films)

  • 윤흥수;이의소;김승일;윤호규;고교청구
    • 한국염색가공학회지
    • /
    • 제17권1호
    • /
    • pp.30-37
    • /
    • 2005
  • The tensile properties, acetic acid solubility and degree of swelling in distilled water of cellulose/chitosan and sericin/chitosan film blended by mixing chitosan acetic acid solution with cellulose solution or sericin solution were investigated and the effect of crosslinking agent on solubility and degree of swelling were also considered. From the experimental results, the model of intermolecular bond is proposed. Tensile modulus of 100% cellulose film is high but the tensile strength and elongation are low. The elongation of 100% chitosan film is high but tensile modulus and strength is low. But it is possible to make film having same or higher tensile strength and modulus compared to that of 100% cellulose film by mixing cellulose and chitosan or by mixing sericin and chitosan. Chitosan is solved in 5vol % acetic acid solution but cellulose and sericin are not solved. Degree of swelling of chitosan in distilled water is higher than that of cellulose and sericin. Lower than 40wt% chitosan content, the solubility of cellulose/chitosan film in 5vol % acetic acid solution shows lower expected value but higher in case of sericin/chitosan film.

두개의 동등한 상호침투 부격자로 구성된 이성분 격자 용액의 혼합자유에너지 (The Free Energy of Mixing for a Binary Lattice Solution Consisting of Two Identical Interpenetrating Sublattices)

  • 정해영
    • 대한화학회지
    • /
    • 제66권4호
    • /
    • pp.278-283
    • /
    • 2022
  • Kirkwood의 방법을 이용하여 단순입방격자나 체심입방격자와 같이 두개의 동등한 상호침투 격자로 구성된 이성분 격자 용액의 자유에너지를 절대온도 역수의 10차항까지 계산하였다. 이를 이용하여 이성분 격자 용액에 대한 액체-액체 공존 곡선과 임계용액온도를 계산하여 분자들의 논랜덤 혼합 효과를 정량적으로 살펴보았다. 그리고 단순입방격자 이성분용액의 공존 곡선을 Monte-Carlo 컴퓨터 모사의 결과와 비교하여 잘 일치하는 것을 알 수 있었다.

3차 상태방정식과 여러 혼합법칙 및 Kirkwood-Buff용액이론을 이용한 초임계유체내에서의 용질의 무한희석 부분몰부피의 계산 (Prediction of partial molar volumes of solutes in supercritical CO2 using the Peng-Robinson equation of state with various mixing rules and Kirkwood-Buff solution theory)

  • 전영표;박종선;권영중
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.253-260
    • /
    • 1999
  • Two thermodynamic models were used to predict the partial molar volumes of solutes in supercritical carbon dioxide at infinite dilution: (1) the Peng-Robinson equation of state with various mixing rules including those based on $EOS/G^E$ (2) the Kirkwood Buff fluctuation integral with the hard sphere expansion (HSE) method. The Kirkwood-Buff fluctuation integral method, in which an equation of state for pure component and molecular parameters are required, produced better results especially near the critical point than the Peng-Robinson equation of state with the several mixing rules based an $EOS/G^E$. When the $EOS/G^E$ mixing rules were used, poorer results were obtained compared with the classical mixing rule and Kirkwood-Buff model.

  • PDF

졸-겔 법을 이용한 실리카 박막의 제조 (Preparation of Silica Films by Sol-Gel Process)

  • 이재준;김영웅;조운조;김인태;제해준;박재관
    • 한국세라믹학회지
    • /
    • 제36권9호
    • /
    • pp.893-900
    • /
    • 1999
  • Silica films were prepared on Si single crystal substrates by sol-gel process using TEOS as starting materials. Films were fabricated by a spin coating technique. Sol solutions were prepared by varying the compositions of CH3OH, H2O and DMF with fixed molar ratio of TEOS=1, HCl=0.05(mol). Wetting behavior viscosity of solutions gelation time thickness of films and cracking behavior were investigated with the various solution compositions. Wetting behaviors of solutions depended on the solution compositions mixing method and mixing rate. The optimum composition of sol was TEOS : DMF ; CH3OH: H2O :HCl=1:2:4:4:0.05(mol) and the mixing rate of solution was optimized at 1 ml/min. Viscosity of solutions were controlled by choosing a reaction time(elapsed time after mixing) at a room temperature so that we could get up to 800nm thick film The surface roughness was getting poor when thickness of films was thicker than 500nm. Thickness of coated films were increased with decreasing amount of CH3OH. The best surface roughness was obtained at the content of CH3OH 4 mol. The shortest gelation time was obtained with the content of CH3OH 8 mol. Crack-free filkms were fabricated when sintered at 500$^{\circ}C$ for 1 hr with heating rate of 0.6$^{\circ}C$/min.

  • PDF

산성폐광폐수를 이용한 매립지 침출수의 응집처리 (Coagulation Treatment of Landfill Leachate Using Acid Mine Drainage(AMD))

  • 최봉종;이승목;이상호
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.129-133
    • /
    • 2000
  • The objective of this study was to invetigate the coagulation effects of landfill leachate by using Acid Mine Drainage(AND). The coagulation efficiency was investigated by mixing landfill leachate with F $e^{+3}$ solution earned by oxidation of pyrite(AMD). In the results of this experiment, it was found that the amount of removed COD and SS was approximately 30% respectively by mixing at the ratio of AMD three to leachate one. And it showed highest turbidity removal efficiency at all mixing ratio. Concentration of Fe was decreased with increasing mixing ratio, however it was increased inversely at mixing ratio 4. Optimal mixing ratio was 3 at the results obtained by leachate coagulation experiments. Also removal efficiency at mixing ratio 3 corresponded to 500mg/$\ell$ of FeC $l_3$ dosage. it was suggested that pretreatment by mixing of AMD and leachate remove both suspended organic material of leachate and metal of AMD.

  • PDF

Transient Response of a Stratified Thermal Storage Tank to the Variation of Inlet Temperature

  • Yoo, Ho-Seon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.14-26
    • /
    • 1998
  • This paper deals with approximate analytical solutions for the two-region one-dimensional model describing the charging process of stratified thermal storage tanks at variable inlet temperature with momentum-induced mixing. An arbitrarily increasing inlet temperature is decomposed into inherent step changes and intervals of continuous change. Each continuous interval is approximated as a finite number of piecewise linear functions, which admits an analytical solution for perfectly mixed region. Using the Laplace transform, the temperature profiles in plug flow region with both the semi-infinite and adiabatic ends are successfully derived in terms of well-defined functions. The effect of end condition on the solution proves to be negligible under the practical operating conditions. For a Quadratic variation of inlet temperature, the approximate solution employing a moderate number of pieces agrees excellently with the exact solution.

  • PDF