• Title/Summary/Keyword: solution leakage

Search Result 403, Processing Time 0.029 seconds

A study on breakthrough characteristics of ion exchange bed with H- and ETAH-form resins for cation exchange in NH3 and ETA solution including trace NaCl (미량의 NaCl을 포함하는 NH3 및 ETA 용액에서 H 및 ETAH 형 수지에 대한 이온교환 파과 특성 연구)

  • Ahn, Hyun-Kyoung;Kim, Youn-Su;Park, Byung-Gi;Rhee, In-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.533-544
    • /
    • 2021
  • Ion exchange (IX) performance on the exchanger bed is essentially evaluated for the generation of ultrapure water in electronics and chemical industries and for the corrosion control in nuclear power plants. The breakthrough characteristics of IX bed with multi-component were investigated with both cation- and mixed-IX beds of H- and ETAH-form for four kinds of cation exchange resins by using the combined solution of ethanolamine (ETA) and ammonia (NH3) at trace NaCl. Unlike major components (ETAH+ and NH4+ ), the phenomena of breakthrough and overshooting at bed outlet were not observed by Na+ over the test period (> 3 times theoretical exchange capacity of IX bed). The breakthrough from H-form resin bed was sequentially reached by ETAH+ and NH4+, while the overshooting was observed for ETAH+ at the breakthrough of NH4+. NH4+ was 51.5% higher than ETAH+ in terms of the relative selectivity determined with the width of breakthrough zone. At the increased concentration of Na+ at bed inlet, the selectivity and the overshooting were decreased and increased, respectively. Na+ leakage was higher from ETAH-form resin bed and was not identical for four kinds of cation-exchange resins, which may be reduced by improving the intrinsic property of IX resin.

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

Enact of Ischemic Preconditioning on Myocardial Protection A Comparative Study between Normothermic and Moderate Hypothermic Ischemic Hearts Induced by Cardioplegia in Rats - (허혈 전처치가 심근보호에 미치는 영향 -적출 쥐 심장에서 상온에서의 심근허혈과 중등도 제체온하에서 심근정지액 사용 시의 비교 연구-)

  • 조성준;황재준;김학제
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.242-254
    • /
    • 2003
  • Most of the studies conducted have investigated the beneficial effects of ischemic preconditioning on normothermic myocardial ischemia. However, the effect of preconditioning could be attenuated through the use of multidose cold cardioplegia as practiced in contemporary clinical heart surgical procedures. The purpose of this study was to investigate whether preconditioning improves postischemic cardiac function in a model of 25℃ moderate hypothermic ischemic heart induced by cold cardioplegia in isolated rat hearts. Material and Method: The isolated Sprague-Dawley rat hearts were randomly assigned to four groups. All hearts were perfused at 37℃ for 20 minutes with Krebs-Henseleit solution before the baseline hemodynamic data were obtained. Group 1 consisted of preconditioned hearts that received 3 minutes of global ischemic preconditioning at 37℃, followed by 5 minutes of reperfusion before 120 minutes of cardioplegic arrest (n=6). Cold (4℃) St. Thomas Hospital cardioplegia solution was infused to induce cardioplegic arrest. Maintaining the heart at 25℃, infusion of the cardioplegia solution was repeated every 20 minutes throughout the 120 minutes of ischemic period. Group 2 consisted of control hearts that underwent no manipulations between the periods of equilibrium and 120 minutes of cardioplegic arrest (n=6). After 2 hours of cardioplegic arrest, Krebs solution was infused and hemodynamic data were obtained for 30 minutes (group 1, 2: cold cardioplegia group). Group 3 received two episodes of ischemic preconditioning before 30 min of 37℃ normothermic ischemia and 30 minutes of reperfusion (n=6). Group 4 served as ischemic controls for group 3 (group 3, 4: warm ischemia group). Result: Preconditioning did not influence parameters such as left ventricular systolic pressure (LVSP), left ventricular end-diastolic pressure (LVEDP), rate-pressure product (RPP) and left ventricular dp/dt (LV dp/dt) in the cold cardioplegia group. (p=NS) However, preconditioning before warm ischemia attenuated the ischemia induced cardiac dysfunction, improving the LVSP, LVEDP, RPP, and LVdp/dt. Less leakage of CPK and LDH were observed in the ischemic preconditioning group compared to the control group (p<0.05). Conclusion: Ischemic preconditioning improved postischemic cardiac function after warm ischemia, but did not protect cold cardioplegic hearts.

Effect of Ischemic Preconditioning on Myocardial Protection - A Comparative Study between Normothermic and Moderate Hypothermic Ischemic Hearts Induced by Cardioplegia in Rats - (허혈 전처치가 심근보호에 미치는 영향 - 적출 쥐 심장에서 상온에서의 심근허혈과 중등도 저체온하에서 심근정지액 사용 시의 비교 연구 -)

  • 조성준;황재준;김학제
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.242-254
    • /
    • 2003
  • Background: Most of the studies conducted have investigated the beneficial effects of ischemic preconditioning on normothermic myocardial ischemia. However, the effect of preconditioning could be attenuated through the use of multidose cold cardioplegia as practiced in contemporary clinical heart surgical procedures. The purpose of this study was to investigate whether preconditioning improves postischemic cardiac function in a model of $25^{\circ}C$ moderate hypothermic ischemic heart induced by cold cardioplegia in isolated rat hearts. Material and Method: The isolated Sprague-Dawley rat hearts were randomly assigned to four groups All hearts were perfused at 37$^{\circ}C$ for 20 minutes with Krebs-Henseleit solution before the baseline hemodynamic data were obtained, Group 1 consisted of preconditioned hearts that received 3 minutes of global ischemic preconditioning at 37$^{\circ}C$, followed by 5 minutes of reperfusion before 120 minutes of cardioplegic arrest (n=6). Cold (4$^{\circ}C$) St. Thomas Hospital cardioplegia solution was infused to induce cardioplegic arrest. Maintaining the heart at $25^{\circ}C$, infusion of the cardioplegia solution was repeated every 20 minutes throughout the 120 minutes of ischemic period. Group 2 consisted of control hearts that underwent no manipulations between the periods of equilibrium and 120 minutes of cardioplegic arrest (n=6). After 2 hours of cardioplegic arrest, Krebs solution was infused and hemodynamic data were obtained for 30 minuts (group 1, 2: cold cardioplegia group). Group 3 received two episodes of ischemic preconditioning before 30 min of 37$^{\circ}C$ normothermic ischemia and 30 minutes of reperfusion (n=6) Group 4 soloed as ischemic controls for group 3 (group 3, 4: warm ischemia group). Result: Preconditioning did not influence parameters such as left ventricular systolic pressure (LVSP), left ventricular end-diastolic pressure (LVEDP), rate-pressure product (RPP) and left ventricular dp/dt (LV dp/dt) in the cold cardioplegia group. (p=NS) However, preconditioning before warm ischemia attenuated the ischemia induced cardiac dysfunction, Improving the LVSP, LVEDP, RPP, and LV dp/dt. Less leakage of CPK and LDH were observed in the ischemic preconditioning group compared to the control group (p<0.05). Conclusion: Ischemic preconditioning improved postischemic cardiac function after warm ischemia, but did not protect cold cardioplegic hearts.

Evaluation of Cavity Wall Adaptation of Bulk-fill Resin Composites in Class II Cavities of Primary Molar (유구치 2급 와동에서 bulk-fill 복합레진의 와동적합성 평가)

  • Bae, Youngeun;Shin, Jonghyun;Kim, Shin;Jeong, Taesung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.446-454
    • /
    • 2017
  • Recently, there have been many studies on bulk-fill resin composites. However, studies on the proper materials for pediatric patients are rare. The aim of this study was to compare the cavity wall adaptation of bulk-fill resin composites with conventional resin composite in class II cavities of primary molars using microcomputed tomography (micro-CT). Standardized class II slot cavities were prepared in 80 exfoliated primary molars and randomly divided into 4 groups. The control group was restored with conventional resin composite, Filtek Z-350 XT (FZ), and the three groups were restored with bulk-fill resin composites, Filtek bulk-fill posterior (FB), Tetric N-Ceram Bulk Fill (TNC), Filtek bulk-fill flowable (FBF). All specimens were thermocycled and then immersed in 50% silver nitrate ($AgNO_3$) solution. Micro-CT was used to measure the penetration volume of the total silver nitrate and the degree of cervical marginal leakage and the number, size, and position of the voids were evaluated. The results revealed that the volume of silver nitrate were significantly different between FB and FZ (p < 0.05). The results also revealed that the penetration length of silver nitrate FBF showed statistically lower than the FZ and FB (p < 0.05). There was no significant difference between the groups in number and size of voids. In conventional resin composite, most of the voids were present inside the restoration (83.3%), but the voids in the bulk-fill resin composites incidence were higher in the gingivoaxial angle. The cavity wall adaptation demonstrated in class II restorations of primary molar by new bulk fill resin composites was similar to conventional incremental technique. Bulk-fill resin composites might be an clinical option for a faster restoration in deciduous teeth.

BOND STRENGTH AND MICROLEAKAGE IN RESIN BONDING TO TOOTH STRUCTURE (치질접착에서 접착강도와 변연누출)

  • Kim, Jin-Hee;Park, Jeong-Won;Park, Jin-Hoon;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.570-577
    • /
    • 1999
  • Intuitively, higher bond strengths should result in less leakage. However, the relationship between bond strengths and microleakage value is complex and not clearly understood. The purpose of this study was to evaluate the relationship between tensile bond strengths and microleakage values in the same restorations to understand the behavior of resin bonding to tooth structure. One-hundred and twenty enamel or dentin specimens from freshly extracted bovine mandibular incisors were used. The specimen was treated with 32% phosphoric acid for 15 seconds and rinsed for 20 seconds. the teeth were divided into four groups by means of wet bonding technique or dry bonding. One-Step$^{TM}$ adhesive were applied to the specimen. The specimens were immersed in 2% methylene blue solution for 7 days, and tensile bond strength and microleakage were measured. The results were as follows: 1. Significant negative correlation was found between bond strengths and micro leakage values. Hence, higher bond strengths seem to be associated with lower microleakage, and vice versa (r=-0 50, p<0.05). 2. The Enamel/Wet group showed significantly higher bond strength than Enamel/Dry one, and Dentin/Wet group showed higher strength than Dentin/Dry one (p<0.05). 3. Microleakage was significantly less ill wet bonding than in dry one at dentin (p<0.05), however, there was no significant difference between wet and dry bonding at enamel (p>0.05).

  • PDF

Influences of Histamine on Permeability across Blood-brain Barrier (혈액-뇌장벽 투과성에 대한 히스타민의 영향)

  • Kim, Kee-Jin;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.33-43
    • /
    • 1968
  • Histamine, 0.5 mg as histamine base in 4 ml of normal saline solution, was injected into rabbits anesthetized with nembutal and the mean blood pressure was kept in the range of $52{\sim}80\;mmHg$ for over one hour by supplemental additions. Following the injection of the test substances, 300 mg of urea and 200 mg of antipyrine intravenously, serial blood samples were obtained from the femoral artery and the internal jugular vein at $0.5{\sim}3$ minutes interval. The decreasing patterns in the concentrations of arterial and venous blood plasma samples were compared with each other. The ratio of the concentration of brain tissue to that of the final arterial plasma was also studied. By these measures the degrees of penetration of the test substances in the brain in the control and in the histamine treated rabbits were observed. The concentrations of antipyrine and urea in the arterial blood plasma were decreasing exponentially with respect to the time elapsed. The venous concentrations were anticipated to increase initially and to cross the arterial concentration curve in the point of equlibrium between the plasma and the tissue. On the contrary to the expectation venous concentration also revealed the decreasing tendency similar to that of arterial plasma. The similarity between these two curves, arterial and venous, would be atributable to the fact that the cerebral blood flow rate was large enough and the rising phase in the venous concentration curve was instantly over before serial blood samples were taken. Inspite of some similarity in the decreasing tedency in both concentration curves there were appreciable discrepancies between the arterial and venous plasma which would reflect the situation far from the equlibria among several compartments in the brain. Changes in plasma potassium levels caused by the injection of histamine or bleeding were observed, too. Using 8 rabbits as the control and 12 rabbits for the histamine treated group following results were obtained: 1. Both of the concentration curves, arterial and venous, declined rapidly at_first and slowly later on and approached same equilibrium concentration with the passage of time after a single injection. The time at which attained the same concentration was $2.0{\pm}0.54\;min.$ in the control and $4.3{\pm}1.92\;min.$ in the histamine treated group with respect to antipyrine. On the other hand in the case of urea they were $2.4{\pm}0.59\;min.$ in the control and $4.4{\pm}1.31\;min.$ in the histamine group, respectively. In the histamine treated group enlarged spaces for distribution of test substances were postulated. 2. The concentration of antipyrine in the brain tissue water revealed no significant differences between the control and experimental groups, showing $212{\pm}40.2\;mg/l$ in the control and $206{\pm}64.1\;mg/l$ in the histamine treated group. On the other hand urea revealed higher value in the histamine treated group than in the control, showing an enhanced penetration of urea into the tissue after injection of histamine. Urea concentration in the brain water was $32.3{\pm}3.36\;mg%$ in the control and $39.2{\pm}4.25\;mg%$ in the histamine treated group. 3. The distribution ratio of antipyrine in the brain tissue was very close to unity in the histamine treated animals as well as in the control. 4. The average of the distribution ratio of urea in the control animals was 0.77 and it showed the presence of blood-brain barrier with regard to urea. However in the histamine treated animals the distribution ratios climbed up to 0.86 and they were closer to unity than in the control animals. Out of 12 cases 5 were greater than 0.9 and 8 exceeded 0.85. It appeared that histamine enhanced the penetration of urea through the barrier. 5. Histamine injection and or hemorrhage caused an elevation of the concentration of potassium in plasma. In the event that histamine and hemorrhage were applied together the elevation of potassium exceed the elevation seen at the histamine alone. There was no evidence that the leakage of potassium from the brain tissue was dominant in comparison with the general leakage from the whole body.

  • PDF

Physical properties of novel composite using Portland cement for retro-filling material (치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰)

  • Lee, Sang-Jin;Cho, Ok-In;Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.445-452
    • /
    • 2010
  • Objectives: The aim of this study was to compare apical sealing ability and physical properties of MTA, MTA - AH-plus mixture (AMTA) and experimental Portland cement - Epoxy resin mixture (EPPC) for a development of a novel retro-filling material. Materials and Methods: Forty-nine extracted roots were instrumented and filled with gutta-percha. Apical root was resected at 3 mm and the retro-filling cavity was prepared for 3 mm depth. Roots were randomly divided into 3 groups of 15 roots each. The retro-filling was done using MTA, AMTA, and EPPC as the groups divided. Four roots were used as control groups. After setting in humid condition for 24 hours, the roots were immersed in 1% methylene blue dye solution for 72 hours to test the apical leakage. After immersion, the roots were vertically sectioned and photos were taken to evaluate microleakage. Setting times were measured with Vicat apparatus and digital radiographs were taken to evaluate aluminum equivalent thickness using aluminum step wedge. The results of microleakage and setting time were compared between groups using one-way ANOVA and Scheffe's post-hoc comparison at the significance level of 95%. Results: AMTA and EPPC showed less microleakage than MTA group (p < 0.05). AMTA showed the highest radio-opacity than other groups and the novel EPPC showed 5 mm aluminum thickness radio-opacity. EPPC showed the shortest initial and final setting times than other groups while the MTA showed the longest (p < 0.05). Conclusions: Under the condition of this study, the novel composite using Portland cement-Epoxy resin mixture may useful for retro-filling with the properties of favorable leakage resistance, radio-opacity and short setting time.

Evaluation of Cumulative and Conditional Antibiotic Release from Vancomycin-Embedded Fibrin Sealant and Its Antibacterial Activity : An In Vitro Study

  • Shin, Dong-Won;Sohn, Moon-Jun;Cho, Chong-Rae;Koo, Hae-won;Yoon, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.45-55
    • /
    • 2020
  • Objective : Fibrin sealants have been used for hemostasis, sealant for cerebrospinal fluid leakage, and adhesive barrier in neurosurgery. Further, as its clinical use and role of an effective drug delivery vehicle have been proposed. This study was performed to measure antibacterial activity and continuous local antibiotic release from different concentrations of vancomycin-impregnated fibrin sealant in vitro. Methods : Antibacterial activity was investigated by disk diffusion test by measuring the diameter of the growth inhibition zone of bacteria (methicillin-resistant Staphylococcus aureus, ATCC29213) from vancomycin-embedded fibrin sealant disc diluted at five different concentrations (C1-C5; 8.33, 4.167, 0.83, 0.083, and 0.0083 mg/disc, respectively). Continuous and conditioned release of vancomycin concentration (for 2 weeks and for 5 days, respectively) were also measured using high-performance liquid chromatography (HPLC) method. To mimic the physiologic wound conditions with in vitro, conditioned vancomycin release in phosphate buffer solution (PBS) was measured and replaced PBS for five consecutive days, half a day or completely daily. Results : In the disk diffusion test, the mean diameters of bacterial inhibition zone were 2.54±0.07 cm, 2.61±0.12 cm, and 2.13±0.15 cm (C1, C2, and C3 respectively) but 1.67±0.06 cm and 1.23±0.15 cm in C4 and C5, respectively. Continuous elution test elicited the peak release of vancomycin from the fibrin sealant at 48 hours, with continued release until 2 weeks. However, conditioned vancomycin release decreased to half or more on day 2, however, the sustainable release was measured over the therapeutic dose (10-20 ㎍/mL) for 5 days and 4 days in assays of half and total exchange of PBS. Conclusion : This study suggests that fibrin sealant can provide an efficient vehicle for antibiotic drug release in a wide range of neurosurgical procedures and the safe and effective therapeutic dose will be at the concentration embedded of 4.167 mg/disc or more of vancomycin.

A Study on Vulnerability Prevention Mechanism Due to Logout Problem Using OAuth (OAuth를 이용한 로그아웃 문제로 인한 취약점 방지 기법에 대한 연구)

  • Kim, Jinouk;Park, Jungsoo;Nguyen-Vu, Long;Jung, Souhwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.1
    • /
    • pp.5-14
    • /
    • 2017
  • Many web services which use OAuth Protocol offer users to log in using their personal profile information given by resource servers. This method reduces the inconvenience of the users to register for new membership. However, at the time a user finishes using OAuth client web service, even if he logs out of the client web service, the resource server remained in the login state may cause the problem of leaking personal information. In this paper, we propose a solution to mitigate the threat by providing an additional security behavior check: when a user requests to log out of the Web Client service, he or she can make decision whether or not to log out of the resource server via confirmation notification regarding the state of the resource server. By utilizing the proposed method, users who log in through the OAuth Protocol in the public PC environment like department stores, libraries, printing companies, etc. can prevent the leakage of personal information issues that may arise from forgetting to check the other OAuth related services. To verify our study, we implement a Client Web Service that uses OAuth 2.0 protocol and integrate it with our security behavior check. The result shows that with this additional function, users will have a better security when dealing with resource authorization in OAuth 2.0 implementation.