• Title/Summary/Keyword: solution cavity

Search Result 367, Processing Time 0.03 seconds

MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES (상아질 접착제의 미세누출과 변연부 혼화층)

  • Cho, Young-Gon;Kim, Young-Kwan;Ahn, Jong-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

Enhanced Nasal Absorption of Ketoconazole by Inclusion with Cyclodextrin (시클로덱스트린과의 포접에 의한 케토코나졸의 비점막 흡수증가)

  • Park, Gee-Bae;Seo, Bo-Youn;Ann, Hong-Jik;Rho, Hyun-Goo;Onn, Yun-Sung;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.95-104
    • /
    • 1994
  • Inclusion complexes of ketoconazole(KT) with ${\alpha}^_$, ${\beta}^_$cyclodextrin(CD) and $dimethy1-{\beta}-cyclodextrin$ (CD) and $dimethy1-{\beta}-cyclodextrin(DM{\beta}CD)$ as nasal absorption enhancer were prepared in 1: 2 molar ratios by freeze-drying and solvent evaporation methods. In order to compare with the intrinsic absorptivity of KT in the jejunum(J) and the nasal cavity(N), the in situ simultaneous perfusion method was employed. The in situ recirculation study revealed that KT-CD inclusion complexes with the greater stability constant and the faster dissolution rate proportionally increased the absorption of KT in the J and N of rats. The rank order of apparent KT permeability$(P_{app}\;:\;cm/sec\;{\time}\;1O^{-5}{\pm}S.E.)$, corrected by surface area of absorption, was $5.10{\pm}0.3(N,\; KT-DM{\beta}CD)$ )> $4.13{\pm}0.4(N,\;KT-{\beta}-CD)$ )> $3.52{\pm}0.2(N,\;KT-{\alpha}-CD)$ )> $2.76{\pm}0.3(J,\; KT-DM{\beta}CD)$ )> $2.61{\pm}0.5(J,\;KT-{\beta}-CD)$ )> $2.42{\pm}0.4(J,\;KT-{\alpha}-CD)$ at pH 4.0. The in crease in permeability of $KT-DM{\beta}CD$ inclusion complex was 2.6 folds in the J and 4.5 folds in the N when the perfusing solution was changed from the buffer(pH 4.0) to saline. The absorption rate of $KT-DM{\beta}CD$ inclusion complex after nasal administration was more rapid than those of ketoconazole alone and $KT-DM{\beta}CD$ inclusion complex after oral administration to rats. In comparision with an oral administration of ketoconazole suspension in corn oil, the relative bioavailability was calculated 137.3% for the oral and 195.0% for nasal $KT-DM{\beta}CD$ inclusion complex in rats. The present results suggest that $KT-DM{\beta}CD$ inclusion complex may serve as a potential nasal absorption enhancer for the nasal delivery of ketoconazole.

  • PDF

Chemical burns of the oral mucosa caused by Policresulen: report of a case (Policresulen 오용에 의한 구강 궤양의 발병 증례 및 화학화상에 대한 고찰)

  • Jung, Jung-Woo;Byun, Jin-Seok;Jung, Jae-Kwang;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.109-114
    • /
    • 2013
  • Chemical burn on the oral mucosa is caused by contact with various chemical products and manifests with localized mucositis, keratotic white lesions, bleeding, and painful tissue surface due to the coagulation of the tissue. Policresulen ($Albothyl^{(R)}$) is a topical antiseptic, commonly used over-the-counter drug for vaginitis, thrush and stomatitis. This drug is highly acidic with pH 0.6, and can act as a strong corrosive agent to oral mucosa. When inadvertently used in oral cavity, it may cause chemical burns of oral mucosa, resulting necrosis and bleeding surface resembling to erythema multifome. A 56 years old female patient presented with the chief complaints of painful ulcerations on the tongue, the upper and lower lips. On intraoral examination, an erythromatous, erosive or ulcerative surface covered with inflammatory exudates or bleeding crust is observed on the anterior half of the tongue and the upper and lower lips. She has occasionally applied the policresulen solution topically on the tongue to relieve pain from recurrent focal glossitis for about 10 years. In this time she applied it broadly and repeatedly to the tongue, the upper and lower lips for the purpose of pain relief by herself without instruction by physician or dentist. After cessation of policresulen application, the oral mucosa was rapidly recovered with use of topical steroids. In 2 weeks the lesions subsided completely. In summary, inadvertent use of $Albothyl^{(R)}$ on oral mucosa may result in chemical burn, causing mucosal erosion, ulceration and inflammation. It can be recovered by topical use of corticosteroid for 2 weeks after cessation of using $Albothyl^{(R)}$.

Separation of Hydrogen-Nitrogen Gases by PTMSP/PDMS-Borosilicate Composite Membranes (PTMSP/PDMS-Borosilicate 복합막에 의한 수소-질소 기체 분리에 관한 연구)

  • Lee, Suk Ho;Lee, Hyun Kyung
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.123-131
    • /
    • 2015
  • The PTMSP/PDMS graft copolymer were synthesized from the PTMSP[poly(1-trimethylsilyl-1-propyne)] and the PDMS[poly(dimethylsiloxane)] and then the PTMSP/PDMS-borosilicate composite membranes were prepared by adding the porous borosilicates to the PTMSP/PDMS graft copolymer. The number-average molecular weight (${\bar{M}}_n$) and the weight-average molecular weight (${\bar{M}}_w$) of PTMSP/PDMS graft copolymer were 460,000 and 570,000 respectively, and glass transition temperature ($T_g$) of PTMSP/PDMS graft copolymer appeared at $33.53^{\circ}C$ according to DSC analysis. According to the TGA measurements, the addition of borosilicate to the PTMSP/PDMS graft copolymer leaded the decreased weight loss and the completed weight loss temperature went down. SEM observation showed that borosilicate was dispersed in the PTMSP/PDMS-borosilicate composite membranes with the size of $1{\sim}5{\mu}m$. Gas permeation experiment indicated that the addition of borosilicate to PTMSP/PDMS graft copolymer resulted in the increase in free volume, cavity and porosity resulting in the gradual shift of the mechanism of the gas permeation from solution diffusion to molecular sieving surface diffusion, and Knudsen diffusion. Consequently, the permeability of $H_2$ and $N_2$ increased and selectivity ($H_2/N_2$) decreased as the contents of borosilicate increased.

EFFECTS OF DENTAL THERAPEUTIC AGENTS ON THE RESPONSE OF THE PULP NERVE (치과치료용 약물이 치수신경의 반응에 미치는 영향)

  • Kwon, Oh-Yang;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.1-15
    • /
    • 1990
  • The aim of this study was to investigate the effect of dental therapeutic agent on conduction velocity and threshold current of intradental A- and C-fibers in the cat. Inferior alveolar nerve of cat anesthetized with sodium pentobarbital was exposed and dissected until response of functional single pulp nerve until could be evoked by monopolar electrical stimulation of the crown of the lower left canine teeth. 10ms rectangular pulse was used to determine the threshold current and 1ms rectangular pulse was used to determine conduction velocity. After application of calcium chloride (1, 2, 6M), calcium hydroxide mixed with saline, potassium chloride (0.2, 0.8, 1.6M), eugenol, zinc oxide eugenol to the cavity on the labial surface, conduction velocity and threshold current of single pulp nerve unit were compared with the control. In 10 cats, 24 $A{\delta}$- and 11 C- pulp nerve units were recorded. The mean conduction velocities of $A{\delta}$- and C-fibers were 7.5m/sec (SD=5.8) and 1.2m/sec (SD=0.4), respectively. The mean threshold current was $12.3{\mu}A$ (SD=5.3) for $A{\delta}$-fibers and $24.9{\mu}A$ (SD=8.1) for C-fibers. 1, 2, 6M calcium chloride caused decrease of conduction velocity and remarkable increase of threshold current in $A{\delta}$- and C-fibers. The effect of calcium hydroxide mixed with saline was similar but smaller than calcium chloride solution. 0.2M potassium chloride had insignificant effect. In 0.8M potassium chloride, the threshold current was increased although conduction velocity was not affected. In 1.6M potassium chloride, the threshold current was increased and the conduction velocity was slowed down. Spontaneous activity was recorded frequently for first 5 min but gradually reduced both in $A{\delta}$- and C-fibers. Eugenol had irreversible effect on pulp nerve in that initially there were not certain changes in the conduction velocity and threshold current of $A{\delta}$- and C-fibers, but the responses to electrical stimulation were abruptly disappeared after sustained application and were not recovered. Contrary to eugenol, zinc oxide eugenol did not caused significant increase of the threhold current and caused time dependent decrease of the conduction velocity, and did not show any irreversible change.

  • PDF

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.

AN IN VITRO STUDY OF MICROLEAKAGE OF COMPOSITE RESINS (복합레진의 미세누출에 관한 연구)

  • Lee, Sun-Young;Yang, Yeon-Mi;Baik, Byeong-Ju;Jeon, Cheol-Wan;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.593-599
    • /
    • 2003
  • The purposes of this study were to evaluate the microleakage of class V composite resin restorations utilizing the different curing lights, to assess the flowable resin, $Filtek^{TM}Flow$(3M Dental Products, USA) and composite resin, $Filtek^{TM}Z250$(3M Dental Products, USA) which need 20s curing time for halogen light could replace $Z100^{TM}$ Restorative(3M Dental Products, USA) for the microleakage, and to evaluate the effect of adhesive resin on marginal microleakage. Light curing units used in this study were conventional halogen light, XL3000(3M Dental Products, USA) and plasma arc light, Flipo(Lokki, France). Class V cavities were prepared and each cavity was filled with each composite resin. After being filled, the teeth were stored in distilled water, polished, thermocycled and soaked in 1% methylene blue solution. Following results were obtained from evaluation of the sectioned surface. 1. There was no statistically significant difference in microleakage of $Filtek^{TM}Flow$ and $Filk^{TM}Z250$ between two kinds of curing units(p>0.05). 2. Flowable resin, $Filtek^{TM}Flow$ showed more microleakage than Z100 and $Filtek^{TM}Z250$ regardless of curing units(p<0.05). 3. Adhesive resin reduced the microleakage of composite resin in both halogen light and plasma arc light(p<0.05).

  • PDF

Fabrication and performance analysis of cost-effective fiber grating lasers for WDM-PON systems (WDM-PON 시스템용 저가형 Fiber Grating Laser의 제작 및 성능 분석)

  • Cho, Seung-Hyun;Lee, Woo-Ram;Lee, Jie-Hyun;Park, Jae-Dong;Kim, Byoung-Whi;Kang, Min-Ho;Shin, Dong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.13-20
    • /
    • 2005
  • Fiber-Bragg-grating external cavity laser(FGL) modules were fabricated and experimentally analyzed. Proposed as a cost-effective solution for optical sources in the WDM-PON access network, FGL modules were packaged to TO-CAN type. We obtained a low threshold current of 13 mA, and an optical output power of 3.6 mW with a bias current of 60 mA at $25^{\circ}C$. The lasing wavelength dependencies on current and temperature were as small as 5.2 pm/mA and 30 pm/$^{\circ}C$, respectively. These change rates of the wavelength with the temperature and current are smaller than those of the DFB laser. Single-mode oscillations with the side-mode suppression ratio(SMSR) over 30 dB are maintained above the threshold current level. The FGL modules can be directly modulated at 155 Mbps, PRBS(2$^{23}$ -1) NRZ signal. Through the BER plots, we did not see the significant degradations before and after the transmission over 20km of the SMF at 155 Mb/s.

COMPARISON OF MARGINAL MICROLEAKAGE BETWEEN LOW AND HIGH FLOWABLE RESINS IN CLASS V CAVITY (5급 와동에서 저유동성과 고유동성 레진의 변연 미세누출 비교)

  • Bae, Sang-Bae;Cho, Young-Gon;Lee, Myeong-Seon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.477-483
    • /
    • 2009
  • The purpose of this study was to compare the microleakage of low and high viscosity flowable resins in class V cavities applied with 1-step adhesives. Forty Class V cavities were prepared on the cervices of buccal and lingual surfaces of extracted molar teeth and divided into four groups (n=8). Cavities were restored with AQ Bond Plus /Metafil Flo $\alpha$, G-Bond/ UniFil LoFlo Plus (Low flow groups), AQ Bond Plus/Metafil Flo and G-Bond/UniFil Flow (High flow group), respectively. Specimens were immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed microleakages at the enamel and dentinal margins. In conclusion, the low viscosity flowable resins showed lower marginal microleakage than do the high vis cosity flowable resins in class V cavities.

A COMPARISON OF APICAL SEAL FOLLOWING "STEP-DOWN/BALANCED FORCE" AND "STEP-DOWN/STEP-BACK" ROOT CANAL SHAPING (Balanced Force와 Step-Back 근관성형후 치근단 폐쇄효과의 비교연구)

  • Lee, Yun-Hee;Kim, Jong-Hwa;Son, Ho-Hyun;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.780-788
    • /
    • 1995
  • The purpose of this study was to compare the apical seal following root canal shaping by different methods. From fourty extracted mandibular 1st and 2nd molars, fourty mesial roots whose canals have some degree of curvature were selected. The mesiobuccal root portion including mesiobuccal portion of a crown was sectioned in each molar. After access cavity preparation for the mesiobuccal canal, working length was determined with # 10 K-file. The sectioned roots were implanted in acrylic resin block and randomly divided into four groups. The canals of group I were shaped by step-down/balanced force, group II by stepdown/step-back, group III by step-back and group IV by conventional method. All of the shaped canals were obturated by Thermafil method and access cavities were filled with IRM. The roots were removed from acrylic resin block and placed in 100 % humidity for 7days. Except the root surfaces of apical 2mm, the root surfaces were nail-varnished 3 times. After the roots were placed in 700 torr vacuum pressure for 15 minutes, they were immersed in 2% methylene blue solution for 4 days. Nail varnishes were removed with acetone. After that, the roots were decalcified in 5 % nitric acid and dehydrated with alcohol series. Transparent specimens were made by methyl salicylate and the quality of apical seal was assessed by measuring the leakage linearly. The results were as follows. 1. The leakage in canals shaped by step-down/balanced force method was significantly less than that in canals shaped by step-back method(P<0.05) and was less but not statistically than that in canals shaped by step-down/step-back method (P>0.05). 2. The leakage in canals shaped by step-down/step-back method was less than that in canals shaped by step-back method, but there was no statistical significance(P>0.05). 3. The leakage in canals shaped by conventional method was significantly more than that in canals shaped by step-down/balanced force, step-down/step-back and step-back method (P<0.05).

  • PDF