• 제목/요약/키워드: solution cavity

검색결과 367건 처리시간 0.026초

A Vapor Sensor Based on a Porous Silicon Microcavity for the Determination of Solvent Solutions

  • Bui, Huy;Nguyen, Thuy Van;Nguyen, The Anh;Pham, Thanh Binh;Dang, Quoc Trung;Do, Thuy Chi;Ngo, Quang Minh;Coisson, Roberto;Pham, Van Hoi
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.301-306
    • /
    • 2014
  • A porous silicon microcavity (PSMC) sensor has been made for vapors of solvent solutions, and a method has been developed in order to obtain simultaneous determination of two volatile substances with different concentrations. In our work, the temperature of the solution and the velocity of the air stream flowing through the solution have been used to control the response of the sensor for ethanol and acetone solutions. We study the dependence of the cavity-resonant wavelength shift on solvent concentration, velocity of the airflow and solution temperature. The wavelength shift depends linearly on concentration and increases with solution temperature and velocity of the airflow. The dependence of the wavelength shift on the solution temperature in the measurement contains properties of the temperature dependence of the solvent vapor pressure, which characterizes each solvent. As a result, the dependence of the wavelength shift on the solution temperature discriminates between solutions of ethanol and acetone with different concentrations. This suggests a possibility for the simultaneous determination of the volatile substances and their concentrations.

영역분할법에 의한 SIMPLER 기법의 병렬화 (Parallel Implementation of SIMPLER by Using Domain Decomposition Technique)

  • 곽호상
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.23-28
    • /
    • 1997
  • A parallel implementation is made of a two-dimensional finite volume model based on the SIMPLER. The solution domain is decomposed into several subdomains and the solution at each subdomain is acquired by parallel use of multiple processors. Communications between processors are accomplished by using the standard MPI and the Cray-specific SHMEM. The parallelization method for the overall solution procedure to the Navier-Stokes equations is described in detail, The parallel implementation is validated on the Cray T3E system for a benchmark problem of natural convection in a sidewall-heated cavity. The parallel performance is assessed and the issues encountered in achieving a high-performance parallel model are elaborated.

  • PDF

다공성 물질이 충전된 정방형 밀폐용기 내에서 수용성 혼합용액의 동결거동에 관한 실험적 연구 (Experimental Study on the freezing of Aqueous Binary Solution Saturated Packed bed in a Square Cavity)

  • 최주열;김병철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.175-182
    • /
    • 1992
  • Freezing of the binary solution ($H_2O-NaCl$) saturating a packed bed of spheres is investigated experimentally. The system is cooled through its top surface, and the bottom is maintained at a temperature above the liquidus. Experiments are performed on the hypolutectic side, and the cold wall temperature is lower than the eutectic point. The effects of initial mixture concentration, superheat and glass bead diameter on temperature and concentration distributions are investigated. Supercooling was observed only at early times of the freezing process for experiments with 5% initial salt concentration. Flow visualization experiments and mushy-liquid interface position observations revealed natural convection in the liquid region. Remelting phenomena was not observed at both the solid-mushy and mushy-liquid interfaces.

  • PDF

신이청매음(辛夷淸肺飮)이 알레르기 비염(鼻炎)에 미처는 효과(效果)에 대한 실험적(實驗的) 연구(硏究) (The Experimental Study on the Anti-Allergic Rhinitis Effects of the Sinichengpae-um)

  • 강상훈;심성용;변학성;김경준
    • 한방안이비인후피부과학회지
    • /
    • 제18권3호
    • /
    • pp.18-25
    • /
    • 2005
  • Objectives: It has a growing interest in the prevention and medical treatment of allergic rhinitis. According to many studies, it's known that Sinicheongpye-um has the inhibitory effect on the allergic rhinitis. We have studied effect of the mice on OVA-induced Production of IL-4, IL-5, $Interferone-{\gamma}$ by Murine Splenocytes and effect of OVA-induced Total IgE. Methods: Mixing Ovalbumin(OVA) $10{\mu}g$ into PBS(phoshate buffered saline) and $Al(OH)_3$, gel solution and changing into $1\;m{\ell}$, we made it into OVA solution. That was administered to normal group. After the last administration into abdominal cavity, we caused allergic rhinitis in nasal cavity of mouse of control group and sample group administering 0.1% solution dropwise 3 times a day for 7 days. Keeping separated serum at -20 degree and after refloating spleen cells, cultivating the cells and centrifuging the upper liquid and keeping it at -20 degree, we measured the amount of IL-4. IL-5, $Interferone-{\gamma}$ and OVA-induced Total IgE by ELISA. Results: 1. In Total IgE, Sinichengpae-um treated group was proved significant inhibitory effect.(p<0.05) 2. In IL-4 study, Sinichengpae-um treated group was proved significant inhibitory effect.(p<0.005) 3. In IL-4 study, Sinichengpae-um treated group was proved significant inhibitory effect.(p<0.001) 4. In $Interferone-{\gamma}$ study, Sinichengpae-um treated group showed a increasing tendency. Conclusion: Based on the above result, it is considered that Sinichengpae-um has the inhibitory effect on the allergic rhinitis of mice and suggested thai it could be used in relieving patients of the symptoms which are caused by allergic rhinitis.

  • PDF

Association of Endometrial Polyps with Membranous Adhesions in Uterine Cavity

  • Lee, Yoon-Jung;Cha, Dong-Hyun;Kim, Ji-Young;Cho, Jung-Hyun;Lee, Gun-Ho
    • 한국발생생물학회지:발생과생식
    • /
    • 제15권4호
    • /
    • pp.291-299
    • /
    • 2011
  • The membranous adhesions could induce implantation failure despite transplantation of high quality of embryo. Clinically, of the patients who have membranous filmy adhesions, endometrial polyps have been found in not infrequently. Thus this study was tried to evaluate the features of endometrial polyps and the effect of endometrial polyps on formation and extents of membranous adhesions in uterine cavity of infertile patients under hysteroscopy. A retrospective study was conducted on 34 infertile patients who were diagnosed as endometrial polyps with membranous adhesions during hysteroscopy from July 2008 to July 2011. Number, size, location and morophologic type of endometrial polyps were investigated. If needed, methylene blue solution was instillated to endometrial cavity to identify membranous adhesions. Then, associations between membranous adhesions with features of endometrial polyps were evaluated. Mean size of endometrial polyp was $1.6{\pm}0.6$ cm, the bigger of endometrial polyps was, the larger of extents of membranous adhesions. (p<0.05). Endometrial polyps were locate evenly in endometrial cavity as follows: anterior uterine wall, 39.1%; posterior uterine wall, 34.8%; lateral uterine wall, 26.1%; upper: 29.4%, middle: 32.4%, lower segment, 35.3%. Mean number of endometrial polyps was $2.26{\pm}1.3$. The pedunculated type was 37.7% and sessile type was 32.4%. There was no statistically significant association of location, number and morphologic type of endometrial polyps with membranous adhesions. In conclusion, hysteroscopy before in vitro fertilization on infertile patients was worthy because of removing of endometrial polyps and membranous adhesions.

복합레진 충전술식에 따른 조미료(장류)의 와동변연 색소 침투에 관한 연구 (A STUDY ON THE COLOUR PENETRATION OF KOREAN FOODS SUBSTANCE TO CAVITY MARGIN OF COMPOSITE RESIN RESTORATION)

  • 안상훈
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.69-76
    • /
    • 1982
  • The purpose of this study was to evaluate the color penetration of cavity margin with composite resin restorations in some Korean foods substance-soy sauce and hot bean paste. Fifty specimans which were extracted caries free third molar of young adults recently. All of the prepared 100 cavities were filled with two kinds of composite resin (Hipol$^{(R)}$and Restodent$^{(R)}$). The experimental specimans were divided into five groups by the following procedures. Group I : Filling of composite resin and polishing. Group II : Filling, polishing, etching of cavity and sealing. Group III : Etching, sealing, filling and polishing. Group IV : Etching, sealing, filling, polishing, and repeated of etching of cavity margin and sealing. Group V : Etching, sealing, filling, polishing, and sealing again without etching. Before examination, the restorated teeth were subjected to thermal cycling ($4^{\circ}C$ and $60^{\circ}C$). All the specimens were immersed in soy and 30% hot bean paste solution under $37^{\circ}C$ incubator during six weeks. Then, the specimens were sectioned bucco-lingually through the center of two restorations with diamond disk and examined under a. metallographic microscope. (Union 6617 U.S.A.) Thereafter, the degree of color penetration was calculated and analyzed. The obtained results were as follows: 1. The color penetration was the lowest in the procedure of Group III which was acid etching, sealing, composite resing filling, and polishing. 2. The color penetration occured in soy and hot bean paste, but the degree of penetration was not so significant statistically between them. 3. The degree of color penetration was not so significant statistically between Hipol$^{(R)}$ and Restondent$^{(R)}$.

  • PDF

와동형태가 5급 와동 수복물의 변연누출에 미치는 영향 (THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION)

  • 박정길;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

수치해의 정확성과 안정성이 보장되는 대류항 미분법 개선에 관한 연구 (Study on the Improvement of the Convective Differencing Scheme for the High-Accuracy and Stable Resolution of the Numerical Solution)

  • 신종근;최영돈
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1179-1194
    • /
    • 1992
  • 본 연구에서는 이 기존의 방법들을 개선하여 비균일격자계에서도 사용할 수 있는 비선형 함수관계를 제시하며, 이 방법과 기존의 해법들을 비교할 때 실제 유동장 에서의 해의 정확도 차이, 전산비용의 경제성등은 어느정도 인지를 밝히고, 또 개선된 해법이 앞서 제시한 좀 더 복잡한 유동장에서도 성공적으로 적용 가능한지의 여부를 판단하는 것을 그 목적으로 한다.

Effects of Pressure Ratio on Population Inversion in a DF Chemical Laser with Concurrent Lasing

  • Park, Jun-Sung;Baek, Seung-Wook
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.287-293
    • /
    • 2004
  • A numerical simulation is presented for investigating the effects of pressure ratio of $D_2$ injector to supersonic nozzle on the population inversion in the DF chemical laser cavity, while a lasing concurrently takes place. The laser beam is generated between the mirrors in the cavity and it is important to obtain stronger population inversion and more uniform distribution of the excited molecules in the laser cavity in order to produce high power laser beam with good quality. In this study, these phenomena are investigated by means of analyzing the distributions of the DF excited molecules and the F atom used as an oxidant, while simultaneously estimating the maximum small signal and saturated gains and power in the DF chemical laser cavity. For the numerical solution, an 11-species (including DF molecules in various excited states of energies), 32-step chemistry model is adopted for the chemical reaction of the DF chemical laser system. The results are discussed by comparison with two $D_2$injector pressure cases; 192 torr and 388.64 torr. Major results reveal that in the resonator, stronger population inversions occur in the all transitions except DF(1)-DF(0), when the $D_2$injection pressure is lower. But, the higher $D_2$injection pressure provides a favorable condition for DF(1)-DF(0) transition to generate the higher power laser beam. In other words, as the pressure of $D_2$injector increases, the maximum small signal gain in the $V_{1-0}$ transition, which is in charge of generating most of laser power, becomes higher. Therefore, the total laser beam power becomes higher.r.

  • PDF

유전체 디스크가 삽입된 원통형 공동 공진기에서 Contour Graph 방법을 이용한 공진주파수 계산 (A Computation of the Resonant Frequencies using Contour Graph Method in the Dielectric-disc Loaded Cylindrical Cavity Resonators)

  • 최홍주;이원희;허정;최광제;이상영
    • 한국전자파학회논문지
    • /
    • 제11권8호
    • /
    • pp.1420-1427
    • /
    • 2000
  • 유전체 디스크가 삽입된 원통형 공동 공진기의 전자계 해와 공진주파수를 구하는 방법을 기술하였다. 유전체 디스크가 삽입된 원통형 공동 공진기의 공진주파수는 특성방정식의 해석에 의해 계산된다. 특성방벙식의 해를 Mathematica의 ContourPlot graph를 이용하여 구하였다. 공진기의 높이를 증가시키면서 계산한 공진주파수와 실험 값의 공진주파수를 비교하였다. 계산결과가 실험값과 거의 일치하는 것을 볼 수 있었다. 공진기 윗면과 동심 유전체 디스크 사이가 근접할 경우 0.2%의 공진주파수 오차를 나타내었고, 공진기 윗면과 동심 유전체 디스크 사이가 멀어짐에 따라 최대 1.6%의 공진주파수 오차를 나타내었다.

  • PDF