• Title/Summary/Keyword: solid bed

Search Result 304, Processing Time 0.023 seconds

Attrition Characteristics of WGS Catalysts for SEWGS System (SEWGS 시스템을 위한 WGS 촉매들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Lee, Seungyong;Jin, Gyoungtae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.122-130
    • /
    • 2014
  • Attrition characteristics of WGS catalysts for pre-combustion $ CO_2$ capture were investigated to check attrition loss of those catalysts, to check change of particle size distribution during attrition tests, and to determine solid circulation direction of WGS catalysts in a SEWGS system. The cumulative attrition losses of two catalysts increased with increasing time. However, attrition loss under humidified condition was lower than that under non-humidified condition case for long-term attrition tests. Between two catalysts, attrition loss of PC-29 catalyst was higher than that of commercial catalyst for long-term attrition tests. However, the commercial catalyst generated much more fines than PC-29 catalyst during attrition. Therefore, we conclude that the PC-29 catalyst is more suitable for fluidized bed operation if we take into account the separation efficiency of cyclone. Based on the results from the tests for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor.

The Effect of Fluidized-Bed Variables on Attrition of Solid Particles (유동층 공정변수의 고체입자 마모에 미치는 영향)

  • Moon, Young-Sub;Yi, Chang-Keun;Son, Jae-Ek;Ryu, Chung-Keol;Choi, Jeong-Hoo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.603-608
    • /
    • 2005
  • This study was conducted to investigate particle attrition characteristics in a gas desulfurization using zinc titanate sorbent in a 0.035 m i.d. by 1.34 m height gas fluidized bed reactor. Gas jetting from the distributor and bubbling in the gas fluidized bed were found to be the main causes of particle attrition. The experiment was carried out under a slow attrition rate condition to compare the performance of the batch reactor to that of a continuous reactor. The attrition index (AI) and corrected attrition index (CAI) were measured at various the gas velocity, temperature, pressure, and bed weight, in the gas fluidized bed, during the dexulfurization process. The AI (5) and CAI (5) decreased as the bed weight increased. Particle destruction occurred when the particles started to experience physical fatigue under specific impacts over several iterations. AI (5) and CAI (5) also increased as relative humidity, gas velocity and pressure increased, and as temperature decreased. Particle attrition was mainly affected by gas jetting from the distributor, and abrasion resulted in smaller particles than fragmentation did.

Characteristics of Minimum Fluidization Velocity and Pressure Fluctuations in Annular Fluidized Beds (Annular 유동층 반응기에서 최소유동화 속도 및 압력요동 특성)

  • Son, Sung-Mo;Kim, Uk-Yeong;Shin, Ik-Sang;Kang, Yong;Choi, Myung-Jae
    • Korean Chemical Engineering Research
    • /
    • v.46 no.4
    • /
    • pp.707-713
    • /
    • 2008
  • Characteristics of minimum fluidization velocity and pressure fluctuations were investigated in an annular fluidized bed whose diameter was 0.102 m and 2.0 m in height. Effects of gas velocity, particle size and bed temperature on the minimum fluidization velocity and pressure fluctuations were examined. The values of minimum fluidization velocity obtained by means of three different methods were very similar each other. The correlation dimension could be a quantitative parameter for expression the resultant complex behavior of gas and solid mixture in the annular fluidized bed. The value of correlation dimension increased with increasing gas velocity, fluidized particle size and temperature in the bed. The minimum fluidization velocity could be determined by means of correlation dimension of pressure fluctuations as well as pressure drop in the bed and standard deviation of pressure fluctuations. The minimum fluidization velocity increased with increasing particle size but decreased with increasing bed temperature in annular fluidized beds. The minimum fluidization velocity was well correlated in therms of correlation dimension as well as operating variables within experimented conditions of this study.

공유결합으로 고정화된 urokinase 칼럼의 스케일업과 solid-phase refolding에 의한 반복 사용

  • Seo, Chang-U;An, Sang-Jeom;Lee, Eun-Gyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.85-88
    • /
    • 2001
  • We scaled up a covalent immobilization system of urokinase to the activated Sepharose and used it repeatedly to cleave a fusion protein consisting of human growth hormone and GST fragment. After scale up from 6 ml to 250 ml, the column system still demonstrated basically the same performance in terms of urokinase immobilization and fusion protein cleavage. When the column was washed with 6M guanidine HCl after the cleavage reaction. the immobilized urokinase showed no activity probably because it was fully unfolded. However. as the denaturant was gradually removed from the column the immobilized urokinase fully regained its bioactivity. which indicated it was properly refolded into its native conformation as covalently attached to the solid matrix. After 20 cycles of this 'solid-phase unfolding/refolding', the immobilized urokinase maintained approx. 80% of the initial bioactivity. This method provides an efficient protocol to apply the solid-phase refolding technique to improve the longevity of immobilized enzyme columns.

  • PDF

The Effect of ZnO Content on the Performance of Spray-dried Zn-based Desulfurization Sorbent for H2 Cleanup (황화수소 정제용 아연계 분무건조 탈황제의 활성성분 함량 변경에 따른 물성 및 반응 특성)

  • Baek, Jeom In;Eom, Tae Hyoung;Lee, Joong Beom;Jegarl, Seong;Ryu, Chong Kul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.482-490
    • /
    • 2014
  • Gaseous sulfur compound such as $H_2S$ or COS in coal- or biomass-derived hot syngas can be purified by solid sorbents at high temperatures. In this study, we investigated the physical properties and reactivity of solid regenerable desulfurization sorbents with 37.2, 41.9, and 46.5wt% ZnO to look into the ZnO content effect. The sorbents were produced by spray-drying method to apply to a fluidized-bed process. Sulfidation and regeneration reaction were carried out using a thermogravimetric analyzer. Sorbent prepared with 46.5wt% ZnO had physical properties suitable for a fluidized-bed process applications such as spherical shape, sufficient mechanical strength and density, high porosity and surface area. It showed high sulfur sorption capacity of 10.4wt% (ZnO utilization of 57%) at reaction temperatures of 500 and $650^{\circ}C$ for sulfidation and regeneration, respectively. However, the sulfur sorption capacity and ZnO utilization were significantly reduced and dimple shape appeared when the ZnO content decreased to 37.2 and 41.9wt%. Sulfur sorption capacity and regenerability were improved as reaction temperature increased within the experimental temperatures used in this work. The reaction temperature zones of $1500{\sim}550^{\circ}C$ and $650{\sim}700^{\circ}C$ are recommended for sulfidation and regeneration, respectively, to lead best reaction performances of the ZnO-based spray-dried sorbents developed in this work.

An Experimental Study on the Treatment of Organic Wastewater by Soil Microbes Using Three-phase Fluidized Bed (삼상유동층 반응기에서 토양미생물에 의한 유기성 폐수처리에 관한 연구)

  • Choung, Youn Kyoo;Chun, Yang Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.207-217
    • /
    • 1992
  • In this study, isolated and cultured nitrogen fixed microbes were seeded in the three-phase fluidized bed in which gas, solid and liquid were contacted directly. Input velocity was varied from 8.12 cm/hr to 16.32 cm/hr. And upflow gas pressure was fixed to 80 psi. Return ratios were from 0.2 to 0.6 with the each experimental condition. According to these condition, movement of media, growth of biofilm and removal efficiency were measured. As the results, in case of briquette ash, biofilm was developed to $170{\mu}m$ when velocity was 8.12 cm/hr and return ratio was 0.6. In this condition, COD removal efficiency was 97% and $NH_4$-N removal efficiency was 83%. At the same condition, biofilm thickness of glass bead was $17.59{\mu}m$ and its COD and $NH_4$-N removal efficiency was 83% and 72%. Nitrogen fixed microbes have following characters: it formed dark-brownish sludge, excellent adhesive force, easy solid-liquid separation and low oxygen uptake ratio, but sensitive to DO concentration. Not only it endured shock loading, but required short time to steady state.

  • PDF

Effect of Operating Parameters on the Phosphorus Removal of Municipal Wastewater in a Pilot-scale Moving Bed Biofilm Reactor with Waste-tire Media (폐타이어 담체를 이용한 파일럿 규모 유동상 생물막 공정에서 하수의 인제거에 미치는 운전인자 영향)

  • Park, Woon-Ji;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.436-441
    • /
    • 2008
  • This work experimentally determined the effect of operating parameters such as temperature and solid retention time (SRT) on the phosphorus removal of municipal wastewater with waste-tire media. The experiments were carried out in pilot-scale moving bed biofilm reactor filled at a 0.15 filling ratio with the media. Total phosphorus (TP) removal efficiency was $91{\pm}5$, $75{\pm}16$, and $59{\pm}14%$ at the temperature of 9~10, 10~20, and $20{\sim}26^{\circ}C$, respectively. TP removal efficiency was $71{\pm}17$, $74{\pm}16$, $74{\pm}16$, and $68{\pm}18%$ at the SRT of 3.5~5, 5~10, 10~15, and 15~20 days, respectively. At the nitrate concentration of 1~3, 3~6, and 6~9 mg/L, TP removal efficiency was $82{\pm}9$, $68{\pm}18$, $47{\pm}7%$, respectively. The concentration of total phosphorus in the effluent was $0.1{\sim}1.8(0.8{\pm}0.4)mg/L$ regardless of operating conditions, which meets Korean phosphorus limit value, 2 mg/L, for discharge into receiving waters.

Analysis of CO2 Capture Efficiency in Relation to the Inlet Moisture Content of the Regenerator in the Continuous Process by using Sorbent Analysis (연속공정에서 고체흡수제의 입자분석을 통한 재생반응기 주입 수분량에 따른 CO2 회수효율 영향 분석)

  • Lee, Do-Young;Kim, Ki-Chan;Park, Young Cheol;Han, Moon-Hee;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.654-658
    • /
    • 2012
  • In this study, $CO_2$ capture efficiency in relation to the inlet moisture content of the regenerator was investigated using potassium-based sorbents in the continuous process composed of two bubbling fluidized-bed reactors, where solid outlet configuration in the regenerator was converted from underflow to overflow. XRD (X-ray Diffraction), SEM (Scanning Electron Microscope) and TGA were performed to find out the effect of water pre-treatment according to inlet moisture content in the regenerator. The $K_2CO_3{\cdot}1.5H_2O$ structure of solid sorbents has been increased as inlet moisture content of the regenerator increased. As a result, the $CO_2$ capture efficiency increased as the $K_2CO_3{\cdot}1.5H_2O$ structure of solid sorbents increased since the reactivity of the sorbents has been improved by that structure generated by the water pre-treatment. And $CO_2$ capture efficiency increased about 3~8% after sorbent outlet configuration of the regenerator was changed underflow to overflow.

Performances of Anaerobic Sequencing Batch Reactor for Digestion of Municipal Sludge at the Conditions of Critical Solid-liquid Separation (혐기성 연속 회분식 공정에 의한 도시하수슬러지 소화시 고액분리 특성에 따른 처리효율평가)

  • Hur, Joon-Moo;Park, Jong-An
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.77-85
    • /
    • 2002
  • The objective of this study was to evaluate the performances of the ASBR under critical conditions of solid-liquid separation, caused by extremely high solids concentration, for wider application of the ASBR to various wastes. The ASBRs and completely-mixed daily-fed control runs were operated using a municipal mixed sludge at 35$^{\circ}C$ and 55$^{\circ}C$. Conversion of completely-mixed daily-fed reactor to sequencing batch mode and changes in HRT of all ASBRs were easily achieved without adverse effect, regardless of digestion temperature. Solids accumulation was remarkable in the ASBRs, and directly affected by settleable solids concentration of the feed sludge. Noticeable difference in solids-liquid separation was that flotation thickening occurred in the mesophilic ASBRs, while gravity thickening was a predominant solid-liquid separation process in the thermophilic ASBRS. Solids profiles at the end of thickening step dramatically changed at solid-liquid interface, and slight difference in solids concentrations was observed within thickened sludge bed. Organics removals based on subnatant or supernatant after thickening always exceeded 80% in all reactors. Thickened sludge volume and gas production of the ASBRs affected mutually. Gas production increased as thickened sludge accumulated, and continuous gas evolution during thickening could cause thickened sludge to expand or resuspend. Thickened sludge volume exceeding a predetermined withdrawal level resulted in loss of organic solids as well as biomass during withdrawal step, leading to decrease in gas production ind SRT. Such an adverse mutual effect was significant in gravity thickening, while it was not sensitive in flotation thickening. Changes in organic loading had no significant effect on organic removals and gas production after build-up of solids in the ASBRs.

Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes (삼상유동층 공정에서 수력학적 Similarity 해석)

  • Lim, Ho;Lim, Hyun-Oh;Jin, Hae-Ryoung;Lim, Dae-Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.790-797
    • /
    • 2011
  • Hydrodynamic similarity was analyzed by employing scaling factor in three phase fluidized beds. The scaling factor was defined based on the holdups of gas, liquid and solid particles and effectivity volumetric flux of fluids between the two kinds of fluidized beds with different column diameter. The column diameter of one was 0.102 m and that of the other was 0.152 m. Filtered compressed air, tap water and glass bead of which density was 2,500 kg/$m^3$ were used as gas, liquid and solid phases, respectively. The individual phase holdups in three phase fluidized beds were determined by means of static pressure drop method. Effects of gas and liquid velocities and particle size on the scaling factors based on the holdups of each phase and effective volumetric flux of fluids were examined. The deviation of gas holdup between the two kinds of three phase fluidized beds decreased with increasing gas or liquid velocity but increased with increasing fluidized particle size. The deviation of liquid holdup between the two fluidized beds decreased with increasing gas or liquid velocity or size of fluidized solid particles. The deviation of solid holdup between the two fluidized beds increased with increasing gas velocity or particle size, however, decreased with increasing liquid velocity. The deviation of effective volumetric flux of fluids between the two fluidized beds decreased with increasing gas velocity or particle size, but increased with increasing liquid velocity. The scaling factor, which was defined in this study, could be effectively used to analyze the hydrodynamic similarity in three phase fluidized processes.