열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험) (Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment))

  • 이욱재;홍희기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

프레넬 필름을 이용한 태양광 채광시스템 연구 (A Study on Solar Light Collector using Fresnel Lens Film)

  • 정학근;한수빈;정봉만;이의준;임상훈
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.81-86
    • /
    • 2002
  • Solar daylighting system provides free and comfort lighting, but its design and control has been key issue due to heavy light collecting system. One of the solutions for the heavy weight issues would be using a light framed film such as fresnel and prism lens. This prototype system consists of light collector, light transformer and light guide luminaire. The light collector which is installed at window or the rooftop concentrates solar light, the collected beam is converted to suitable light by the light transformer. and the prism light guide luminaire has been used to distribute light emitted from light transformer for illumination. In this paper, the design concept and performance of light collector in this prototype system are presented.

평판형 액체식 PVT 모듈의 성능 실험 분석 (An Experimental Study of PV/Thermal Combined Collector Module)

  • 강준구;김진희;김준태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.780-785
    • /
    • 2009
  • The photovoltaic/thermal collectors (PV/T collectors) combine the solar thermal collector and photovoltaic modules. They can produce thermal energy in the form of hot air or hot water, and converts solar radiation into electricity. The collecctors can improve the electrical performance of PV modules as the heat from the PV module carried away by the thermal part of the system keeping temperatures lower. The basic water cooled PVT collector has metallic water pipes attached to the back of a PV collector. There are main parameters affecting the performance (electrical and thermal) of PVT collectors. This paper analyzed the experimental performance of glazed water PVT module, considering the parameters of solar radiation, inlet water temperature and ambient temperature. It found that solar radiation is the dominant factor for the electrical performance of the collector, and for the thermal performance the inlet water temperature and ambient temperature appeared to be more related.

  • PDF

지열을 이용한 공조외기부하저감 시스템에 관한 연구 - 공기식 집열기와의 병용에 의한 공조외기부하저감 효과 - (Study on Fresh Air Load Reduction System by Using Geothermal Energy - Reducing Effect of a Fresh Air Load by Combining with Air-heated Solar Collector -)

  • 손원득;이성
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1218-1226
    • /
    • 2004
  • This paper presents thermal behaviors and performances of a fresh air load reduction system by using earth tube system combined with air-heated solar collector. The earth tube system reduces a fresh air load by heat exchange with soil throughout the year. In the previous experimental research, it was clarified that the earth tube system was very useful as a fresh air load reduction system. However, since outlet temperature of the fresh air which was heated by earth tube system was below 15$^{\circ}C$ in winter, it is not suitable to introduce the fresh air into the place of residence directly. Therefore, a simulation model using the simple heat diffusion equation was used to examine a rising effect of outlet air temperature in winter by combining with air-heated solar collector. An improvement of annual performance by control of operation is also quantitatively examined. In conclusion, it is confirmed that its performance is improved by control of operation throughout the year and outlet air temperature rose by combining with air-heated solar collector.

반사경 배치 및 흡수기 형상에 따른 접시형 태양열 집열기의 열손실 해석 (Analysis of Heat Loss with Mirror Array and Receiver Shapes on the Dish Solar Collector)

  • 서주현;마대성;김용;강용혁;서태범
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.35-41
    • /
    • 2008
  • The radiative heat loss from a receiver of a dish solar collector is numerically investigated. The dish solar collector considered in this paper consists of a receiver and multi-faceted mirrors. In order to investigate the performance comparison of dish solar collectors, six different mirror arrays and four different receivers are considered. A parabolic- shaped perfect mirror of which diameter is 1.40 m is considered as the reference for the mirror arrays. The other mirror arrays which consist of twelve identical parabolic-shaped mirror facets of which diameter are 0.405 m are suggested for comparison. Their reflecting areas, which are 1.545 $m^{2}$, are the same. Four different receiver shapes are a conical, a dome, a cylindrical, and a unicorn type. The radiative properties of the mirror surfaces and the receiver surfaces may vary the thermal performance of the dish solar collector so that various surface properties are considered. In order to calculate the radiative heat loss in the receiver, two kinds of methods are used. The Net Radiation Method that is based on the radiation heat balance on the surface is used to calculate the radiation heat transfer rate from the inside surface of the receiver to the environment. The Monte-Carlo Method that is the statistical approach is adopted to predict the radiation heat transfer rate from the reflector to the receiver. The collector efficiency is defined as the results of the optical efficiency and the receiver efficiency. Based on the calculation, the unicorn type has the best performance in receiver shapes and the STAR has the best performance in mirror arrays except the perfect mirror.

무창 기공형 태양열 공기 난방 모듈 성능 모니터링 연구 (Performance Monitoring Study of Unglazed Transpired Solar Air Heating Module)

  • 강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.67-72
    • /
    • 2002
  • Solar Air Systems (SAS) have unique advantages for space heating and tempering ventilation air. Air, unlike water, needs no protection against freezing nor are leaks damaging to the building structure or its contents. In contrast to glazed collector, unglazed steel solar collector may have higher efficiencies over glazed flat collector due to the absence of the glass. Therefore, the monitoring of SAS is so important to evaluate actual performance of SAS for right applications. This study is to provide a testing method with a movable test cell developed in KIER to evaluate the thermal performance of SAS based on international standard method ASHRAE 93-86, "Method of Testing to Determine the Thermal Performance of Solar Collectors". The monitoring tool used advanced technique LabVIEW 6i with portable notebook computer. Sample results have been obtained to access the performance of a reference and a target SAS module. The process and tool introduced here could be used to provide a performance verification data for future implementation study applications.

Prismatic Solar Hybrid Collector 시스템의 에너지 성능 평가에 관한 연구 (Energy Performance Assessment Study of Prismatic Solar Hybrid Collector System)

  • 박준언;김기세;이의준;정모
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.51-58
    • /
    • 2003
  • PSHC(Prismatic Solar Hybrid Collector) is a passive solar system composed of prismatic acrly glazing, glazing and ventilating fan. This PSHC system is applied to effectively reduce heating ventilation load as well as lighting load. But so far no method appraising thermal performance of this PSHC system has been developed yet. To assess thermal performance of the PSHC system, a prototype PSHC experimental facility and TRNSYS subroutine type-205 model have been developed in Korea Institute of Energy Research (KIER). The results indicated that l)TRNSYS empirical model of PSHC has been properly modeled with actual performance data, 2)a more reliable source of weather data such as NASA and KIER weather station have been also obtained, and therefore, 3)the annual energy performance of PSHC could be assessed based on this proposed TRNSYS model.

외부집열판형(外部集熱板型) 태양열(太陽熱) 목재건조기(木材乾燥機)의 집열효율(集熱效率)과 적정(適正) 집열면적(集熱面積) 분석(分析) (Analysis of Collector Efficiency and Proper Collector Size of External Collector Type Solar Lumber Dryer)

  • 이형우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제18권4호
    • /
    • pp.41-52
    • /
    • 1990
  • Experimental external collector type solar lumber dryer with $1.6m^2$ of collector area and $1.0m^3$ of maximum dryer capacity was designed and constructed to investigate the conditions inside and outside the dryer and collector. The efficiency of collector was calculated and numbers of drying-days and collector areas required to dry $0.2m^3$ and $1.0m^3$ of pine and oak at various an flow rate inside collector were estimated for eight cities in Korea. Average temperatures of collector-inlet and -outlet air and heat absorber were $52.5^{\circ}C$ $57.9^{\circ}C$, and $71.1^{\circ}C$. respectively at 4m/sec of an flow rate inside collector on sunny day in summer. Overall heat transfer coefficient of collector was 4.875W/$m^2^{\circ}C $ and collector efficiency was 52%. Estimated numbers of drying-days required to dry $0.2m^3$ of pine and oak from 80% to 15% moisture content at various air flow rate inside collector were 38 and 66 days. respectively. Areas of collector required to dry $1.0m^3$ of lumber at desired safe drying rate were estimated as $13.7m^2$ for pine and $16.0m^2$ for oak.

  • PDF

Rock-pile식(式) 집열기(集熱器)를 이용(利用)한 농산물건조(農産物乾燥)에 관(關)한 연구(硏究) (Drying of Agricultural Products by the Flat-plate Solar Collector with Rock-piled Heat Storage Medium)

  • 장규섭;김만수
    • Applied Biological Chemistry
    • /
    • 제26권2호
    • /
    • pp.75-81
    • /
    • 1983
  • 태양열(太陽熱) 축열장치(蓄熱裝置)의 개발(開發)을 위(爲)한 기초자료(基礎資料)를 얻기 위(爲)하여 태양열(太陽熱)의 축열매체(蓄熱媒體)로 돌을 이용(利用)한 평판집열기(平板集熱器)을 제작(製作)하여 집열기(集熱器)의 효율(效率), 총열전달계수(總熱傳達係數), 집열기(集熱器)에 의(依)한 상승온도등(上昇溫度等)을 분석(分析)하고 이를 열원(熱源)으로 벼와 고추에 대(對)한 건조실험(乾燥實驗)을 하였다. 초기함수율(初期含水率) 24.5%인 벼를 14.5%까지 건조(乾燥)시키는데 상온통풍건조(常溫通風乾燥)에서는 약(約) 18일(18日), 튜브형집열기(型集熱器)에서 약(約) 12일(12日), 평판집열기(平板集熱器)에서 약(約) 10일(10日)이 소요(所要)되었으며 통고추 건조(乾燥)의 경우 일광건조(日光乾燥)에서 약(約) 68시간(68時間), 튜브형집열기(型集熱器)에서 약(約) 38시간(38時間), 평판집열기(平板集熱器)에서 약(約) 36시간(36時間)이 소요(所要)되었다. 고추를 절단(切斷)하여 건조(乾燥)할 경우 수평(水平)으로 절단(切斷)하는 것이 효과적(效果的)이었으며 건조(乾燥) 과정중(過程中) capsanthine과 capsaicine성분(成分)의 변화(變化)는 건조방법(乾燥方法)이나 절단방법(切斷方法)에 따라 고추의 품질(品質)에 영향(影響)을 미치는 정도(程度)는 아니라고 사료(思料)되었다.

  • PDF

진공관형 집열기 히트파이프 접촉방식에 따른 집열성능 비교 (Comparison of Collecting Performance according to Contact Types of Heatpipe in Vacuum Tube Type Solar Collector)

  • 윤지훈;정인국;이중섭;정경택;서정세
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.122-127
    • /
    • 2011
  • In this study, it was compared collecting performance according to contact types between heatpipe and manifold of vacuum tube type solar collector. Between two types, direct contact type is better in collecting performance. On the other hand, Indirect type have advantage in maintenance. In the result of numerical analysis, As the temperature of heatpipe and flow rate of working fluid increased, difference of outlet mean temperature of two types became large. Also, it could be confirmed, as contact resistance between heatpipe and copper tube in indirect type increased, the difference increased too. Useful data in selection and design in vacuum tube type solar collector were proposed by the results of numerical analysis.