• 제목/요약/키워드: solar collector

검색결과 442건 처리시간 0.024초

사무소 건물 태양열급탕시스템의 LCC 최적화에 따른 에너지성능 변화 분석 (Energy Performance Variation of Solar Water Heating System by LCC Optimization in an Office Building)

  • 고명진;최두성;장재동;김용식
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.89-98
    • /
    • 2011
  • This study examined the energy performance according to the main design parameters of a solar water heating system for an office building using the life cycle cost (LCC) optimization simulations. The LCC optimization simulations of the system were conducted with TRNSYS and GenOpt employing the Hooke-Jeeves algorithm for cases where water temperature was $60^{\circ}C$ and $50^{\circ}C$. The results showed that for water temperature at $60^{\circ}C$ and $50^{\circ}C$ the global radiation incident on the collector could be decreased by 16.98% and 28.52%, collector useful energy gain could be decreased by 15.04% and 22.59%, energy to load from storage tank could be decreased by 10.86% and 18.06% and AH energy to load could be increased by 16.86% and 38.50% respectively compared to a non-optimized system. The annual average collection efficiency of the collector was increased by 0.88% for $60^{\circ}C$ and 2.78% for $50^{\circ}C$ because of increase of collector slope and decrease of the mass flow rate per collector area. The annual average efficiency of the system was increased by 1.74% and 3.47% compared to the basis system. However, the annual solar fraction of the system was decreased by 6.68% for $60^{\circ}C$ and 11.26% for $50^{\circ}C$ due to decrease of collector area and storage tank volume.

단일 진공관형 집열기 히트파이프 작동유체에 따른 열성능 연구 (Thermal Performance Study of Various Heat Pipe Working Fluid for Evacuated Tubular Solar Collector)

  • 주홍진;김정배;김종보;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.97-103
    • /
    • 2007
  • This study was carried out to compare the thermal performance and operating characteristics of evacuated tubular solar collector(ETSC) with different working fluid. The evacuated tubular solar collectors with different working fluid of heat pipe were investigated in the same operating condition for a indoor experiment equipment. First, the result of working fluid with Water showed that $F_R({\tau}{\alpha})$ was 0.6636 and $F_RU_L$ was -1.8457 Second, Ethanol showed that $F_R({\tau}{\alpha})$ was 0.6147 and $F_RU_L$ was -0.6365. Third, Flutec-pp9 showed that $F_R({\tau}{\alpha})$ was 0.515 and $F_RU_L$ was -3.2313. Finally MA's showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_RU_L$ was -2.0086.

평판형 태양열 집열판의 집열관 온도분포 특성 (The Characteristics of Temperature Distributions for Flat Tube Type Solar Collector Type)

  • 모종근;배철환;정효민;정한식
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.85-91
    • /
    • 1999
  • This study represented experimental research on the flat-plate solar collector. The heat performances were measured the tube array surface temperature by thermal-couple. The solar collector($W{\times}H$) of $580{\times}1100$, various tilt angles of 30, 45, 60 degree and the internal tube number of 4, 6, 8, 10(ea) were utilized in the present investigation. It is found that the thermal concentration is higher as the tilt angle become larger and the solar tubes are more and more. In this stuby obtained results of following: The array of tubes in collector has the best nice in that the number of tube is eight and the tilt angle is 60 degree. The collect energy by each tube array shown high value by increase the number of tubes and tilt angles. In addition to, the collect energy depends on by the tilt angle than the number of tube.

  • PDF

지역별 기상조건과 급수온도에 따른 태양열 온수공급 시스템 성능에 관한 연구 (A Study on Performance of Solar Thermal System for Domestic Hot Water According to the Weather Conditions and Feedwater Temperatures at Different Locations in Korea)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.41-54
    • /
    • 2019
  • The purpose of this study is to analyze the performance of solar thermal system according to regional weather conditions and feedwater temperature. The performance analysis of the system was carried out for the annual and winter periods in terms of solar fraction, collector efficiency and it's optimal degree. The system is simulated using TRNSYS program for 6 cities, Seoul, Incheon, Gangneung, Mokpo, Gwangju, and Ulsan. Simulation results prove that the solar fraction of the system varies greatly from region to region, depending on weather conditions and feedwater temperatures. Monthly average solar fraction for winter season from November to February, a time when heat energy is most required, indicated that the highest is 73.6% in Gangnueng and the lowest is 56.9% in Seoul. This is about 30% relative difference between the two cities. On the other hand, the collector efficiency of the system for all six cities was analyzed in the range between 40% and 42%, indicating small difference compare to the solar fraction. The annual average solar fraction is rated the highest at 40 collector degree, while monthly average solar fraction during winter season is rated at 60 degree.

화학적 환원법으로 제조된 은나노유체를 사용한 직접흡수식 태양열 집열기의 효율 (Efficiency of a Direct Absorption Solar Collector using Ag Nanofluids Synthesized by Chemical Reduction Method)

  • 이승현;박용준;최태종;장석필
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.65-72
    • /
    • 2014
  • In this paper, the water-based Ag nanofluids are synthesized by the chemical reduction method and their extinction coefficients are measured by an in-house developed measurement device. The Ag nanofluids are manufactured by the chemical reduction method with the mixing of silver nitrate ($AgNO_3$) and sodium borohydride ($NaBH_4$) in an aqueous solution of polyvinyl pyrrolidone (PVP). The extinction coefficients of Ag nanofluids are measured by means of the in-house developed apparatus at a wavelength of 632.8nm according to the particle volume fractions. The results show that the extinction coefficient of water-based Ag nanofluids increases with the increase of nanoparticle concentrations. Finally, the temperature field and efficiency of direct absorption solar collector (DASC) are analytically estimated based on the measured extinction coefficient of water-based Ag nanofluids. The results indicate that the direct absorption solar collectors using nanofluids have the feasibility to improve the efficiency of conventional flat-plate solar collectors without using an absorber plate.

태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구 (Experimental Study for Estimation of Air Heating Performance and Improvement of Thermal Performance of Hybrid Solar Air-water Heater)

  • 최휘웅;김영복;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.47-57
    • /
    • 2017
  • Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector's inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about $43^{\circ}C$ to $60^{\circ}C$ on the $30^{\circ}C$ of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

핀-튜브 열교환 구조를 갖는 복합집열기에서 핀 높이 및 간격에 따른 공기열 이용 액체 가열 성능에 관한 수치해석 연구 (Numerical Analysis on Heat Gain of Liquid from Ambient Air with Various Fin Heights and Pitches of Fin-and-Tube Heat Exchanger in Hybrid Solar Collector)

  • 최휘웅;파쿠르 로커만;류남진;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제36권3호
    • /
    • pp.53-61
    • /
    • 2016
  • Solar assisted heat pump system uses solar thermal energy as a heat source of evaporator of heat pump. So, COP can be enhanced as well as collector efficiency. For improving performance of this system, some research about hybrid solar collector that has fin-and-tube heat exchanger has been conducted. This collector can get a thermal energy from ambient air for liquid heating, so heated liquid can be used as a heat source of evaporator in heat pump even the solar radiation is not enough. In this study, numerical analysis was conducted for confirming heat gain of liquid according to fin height and pitch of fin-and-tube heat exchanger in collector. As a result, higher heat gain was obtained on lower fin height and narrow fin pitch, but the pressure drop also increased with increment of heat gain. Thus the JF factor considering both heat transfer enhancement and pressure drop was investigated and the maximum value was shown when the fin height and pitch were 40mm and 45mm. So it is considered that this installation condition has a highest heat transfer improvement when comparing with pressure drop. However heat gain of liquid at this condition was less than the other installation conditions of fin pitch on same height. Then, after establishing a proper minimum heat gain of liquid, actual production and experiment of collector will be conducted with fin height and pitch showing maximum JF factor and satisfying selected minimum heat gain of liquid on the basis of results of this study.

PVT 시스템의 PV 모듈 및 태양열 집열기 대비 성능 및 효율 비교분석 (The Performance and Efficiency Analysis of a PVT System Compared with a PV module and a Solar collector)

  • 어승희;이정빈;최윤성;김대현
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.1-10
    • /
    • 2012
  • A photovoltaic/thermal (PVT)solar system is the solar technology that allows for simultaneous conversion of solar energy into both electricity and heat. This paper compared the performance of PVT system with a conventional PV module and solar collector and analyzed electrical and thermal efficiency of PVT system in terms of solar irradiance and inlet temperature of the working fluid. Based on the experimental data, thermal and electrical efficiencies of he glazed PVT system were57.9% and14.27% under zero reduced temperature condition which were lower by 13.6% than the solar thermal absorber plate and by 0.08% than the PV module respectively. For the unglazed PVT system it had lower thermal efficiency than the solar thermal absorber plate but higher electrical performance than the PV module due to the cooling effect by the working fluid. However, total efficiency of the glazed PVT system was72.2% which was higher than combined efficiencies of the solar collector and PV module. Besides, total efficiency of the PVT system would be much higher if calculated based on unit area.

온수 취득용 물탱크에 자연대류 방식 도입을 위한 단일진공관 태양열집열기의 성능평가 연구 (Evaluation of Solar Collector to Introduce Natural Convection in Water Tank to Obtain Warm Water)

  • 도승주;양영준
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.22-29
    • /
    • 2018
  • The purpose of this study was to evaluate the performance of a solar collector to introduce natural convection in a water tank as a means of obtaining warm water. Numerical analysis was performed to predict the characteristics of the solar collector and its performance was verified using an experimental method. The single vacuum structure of the collector enabled natural convection when it was fitted on the water tank. Based on numerical analysis, warm water of $31-54^{\circ}C$ was obtained when the inlet temperature of cold water was $20^{\circ}C$. Furthermore, the temperature of the warm water could be predicted under various conditions as well as the experimental conditions created for this study.