• Title/Summary/Keyword: soil thickness

Search Result 576, Processing Time 0.031 seconds

Effect of cobalt sulfate contents on the ceramic surface coating using spray technique (스프레이 기술을 이용한 세라믹 표면 코팅에 대한 황화코발트 첨가량의 영향)

  • Park, Hyun;Kim, Kyung-Nam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.6
    • /
    • pp.256-260
    • /
    • 2014
  • This study was carried on the phenomena in reactivity with the clay surface according to the thickness of the cobalt component coating. In the coated specimen, it was observed that the cobalt component was spreaded to diffuse with a constant thickness from the surface of it and the diffusion layer at the white porcelain soil was more increased with the increase of the amount of cobalt sulfate than at the celadon porcelain one. It was evaluated that the color of the surface on the coated specimen at the white porcelain soil was changed from grayish blue to blue and the $L^*$ value was decreased from 51.78 to 37.61 and also in the case of the coated specimen in celadon porcelain soil, $L^*$ value was from 53.91 to 38.93 and the color was from dark olive gray to dark gray. The physical properties of the specimen were characterized by X-ray diffraction, Scanning electron microscope, Dilatometer, TG-DTA, UV-vis spectrophotometer and HRDPM.

Regional Differences in Onion Bulb Quality and Nutrient Content, and the Correlation Between Bulb Characteristics and Storage Loss

  • Lee, Jongtae;Ha, Injong;Kim, Heedae;Choi, Silim;Lee, Sangdae;Kang, jumsoon;Boyhan, George E.
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.807-817
    • /
    • 2016
  • Many onion growers and researchers assert that differences in soil type, agricultural practices, weather, and duration of prolonged onion cultivation in a particular field could affect onion bulb quality. This study evaluates the bulb quality of onions grown in different regions and determines the correlations between bulb characteristics and postharvest loss during cold and ambient storage. Soil and onion bulbs were collected from fields in six onion growing regions in Korea, during the growing season of 2011-2012. The fresh weight, dry matter content, and carbon (C), sulfur and magnesium contents of the onion bulbs were significantly affected by the location in which they were grown. Bulbs grown in Muan had the greatest number of scales, thinnest scale thickness, and the highest total soluble solids (TSS) and total flavonoids (TF). Bulbs originating from Jecheon had the lowest pyruvic acid (PA), total phenolics and TF. Storage loss of bulbs from the different regions was similar in refrigerated storage, but differed in ambient temperature storage. Bulb fresh weight was positively correlated with scale thickness (r = 0.617) and cold storage loss (CSL; r = 0.398). Dry matter content was positively correlated with C (r = 0.958) and TF (r = 0.256) contents, while it was negatively correlated with CSL (r = -0.424). CSL was primarily affected by the fresh weight, as well as the dry matter, C, and PA contents of the bulbs, while ambient storage loss was primarily influenced by the amount of TSS.

Evaluation of Growth Characteristics and Groundwater Levels for the Growth and Development of Sorghum (Sorghum bicolor L.) and Adzuki bean(Vigna anaularis L.)

  • Ryu, Hee-La;Adhikari, Arjun;Kang, Sang-Mo;Kim, Yoon-Ha;Lee, In-Jung
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.13-25
    • /
    • 2018
  • Appropriate water level is the primary factor for the optimal yield of crop plants. The required water level varies according to the variety of the crops. In the present study, we investigated the optimum requirement of groundwater level(GWL) to grow sorghum and adzuki bean under paddy field soil. Here, we cultivated sorghum and adzuki bean using lysimeter filled with paddy soil under GWL 0 cm(NT) and GWL(20, 40 cm) where GWL 20 cm is maintained as a waterlogging condition. The plant growth promoting attributes were measured on the first day after treatment(0 DAT), 10 DAT and 20 DAT. The results showed that the growth parameter such as shoot length, leaf length, leaf width, and stem thickness of both sorghum and adzuki bean were constantly increased and were found higher at GWL 40 cm(except stem thickness and leaf width in sorghum at 20 DAT). The physiological parameters such as chlorophyll content and stomatal conductance were also found higher at GWL 40 cm in all DAT. In addition, the elements like P and K contents in adzuki bean, and Ca content in sorghum were constantly increased and was found higher in GWL 40 cm at all DAT. These results suggest that the GWL of 40 cm is appropriate for production of sorghum and adzuki bean especially in case of paddy soil.

The Freezing Characteristics of Pavement Layer Using the Field Road Model Test (현장도로 모형실험을 이용한 포장구성층의 동결 특성 분석)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.71-80
    • /
    • 2010
  • Korea is considered to be a seasonal frozen soil area that thaws in the spring, and freezes in winter. In the current design codes for anti-freezing layer, the thickness of anti-freezing layer is calculated by the depth frozen due to the temperature condition. Therefore, there is a tendency of over-design and applying uniform thickness without the consideration of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential to study the structural appropriateness of pavement layer and bearing capacity besides the seasonal and mechanical properties of pavement materials to take an appropriate and reasonable design of the road structure. In this paper, the evaluation of frost susceptibility on subgrade, ant-freezing layer, subbase was conducted by means of the mechanical characteristics and model experiment. The temperature, heaving amount, unfrozen water contents and freezing depth of soil samples, the subgrade, anti-freezing layer, subbase soils of road construction site were measured to determine the frost susceptibility.

Investigation of Proper Replacement Depth for the Reinforced Earth Wall on a Soft Ground by Finite Element Analysis (유한요소해석에 의한 연약지반 상 보강토 옹벽에 대한 적정 치환깊이 검토)

  • Lee, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.153-162
    • /
    • 2007
  • For the reinforced earth wall constructed on a soft ground in parallel with replacing soft soils, the behavior of the wall according to variations of thickness and stiffness of soft layer, replacement depth, and wall height is investigated using a finite element method, in which incremental construction steps including consolidation of soft soil layer are considered. The behavior of wall is characterized by investigating displacements and settlements developing at the wall, and shear strains developing in a soil deposit. The stability of wall is, then, evaluated by comparing these values with the safety criteria determined on the basis of the literature. Based on the investigation, it is shown that the behavior of wall is influenced naturally from soft soil thickness(t), replacement depth(d) and wall height(h), but more significantly from d and h. In addition, it is also shown that the normalized replacement depth, d/h, required for the safety of wall is not influenced significantly by the variations of t and h. Consequently, it can be concluded that the proper replacement depth can be suggested in an equivalent value in terms of d/h, even for the cases where the wall height is varying with stations, but the variation is not significant.

Extensive analysis of several Indian and Yemeni soils' gamma-ray shielding characteristics: An experimental and simulation approach

  • Shamsan S. Obaid;M.I. Sayyed;A.S. Alameen;D.K. Gaikwad;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3558-3565
    • /
    • 2024
  • The linear attenuation coefficients (LAC) of four soils (Black cotton (S1), Sandy (S2), Clay (S3), and Sandy (S4)) samples were measured at photon energies released from radioisotopes Co57 (122 keV), Ba133 (356 keV), 22Na (511 and 1275 keV), Cs137 (662 keV), Mn54 (840 keV), and Co60 (1330 keV) using a gamma spectrometer includes a NaI (Tl) scintillation detector. The experimental measurements were confirmed utilizing the Monte Carlo N-particle transport code. The linear attenuation coefficient values enhanced from 0.256 cm-1 to 0.296 cm-1 (at Eγ of 122 keV), from 0.126 cm-1 to 0.142 cm-1 (at Eγ of 662 keV), and from 0.0938 cm-1 to 0.105 cm-1 (at Eγ of 1275 keV), raising the (Fe + Mn) concentration from 0.912 wt% to 11.214 wt%, as well as raising the soil samples density from 1.62 g/cm3 to 1.79 g/cm3. The study also shows an enhancement in the half value thickness, transmission factor, radiation protection efficiency and lead's equivalent thickness due to the enrichment of Fe + Mn concentrations within the studied soils. The results show that the Black cotton soil exhibits better shielding properties for γ-ray than the other soils.

A Large Slipping Finite Element Model for Geosynthetics Interface Modeling

  • Yi, Chang-Tok
    • Geotechnical Engineering
    • /
    • v.12 no.3
    • /
    • pp.35-48
    • /
    • 1996
  • Reinforced soil structures may experience large local movements between soil and reinforcement. The failure modes of a reinforced structure depend on several factors which are governed by deformation and slipping of the reinforcement. In some cases, pulling out of the reinforcement may occur instead of rupturing, The growing use of geosynthetic liner system for storage of solid and liquid wastes has led to a number of slope instability problems where the synthetic liner may undergo a large amount of stretching and slipping as a result of the loading. The conventional finite element model for the soil-reinforcement interface uses a zero thickness joint element with normal and shear stiffnesses and can only accommodate a small amount of deformation. When a large slippage occurs, the model provides an i ncorrect mechanism for deformation. This paper presents a new interface finite element model which is able to simulate a large amount of slippage between soil and reinforcement. The formulation of the model is presented and the capability of the model is demonstrated using illustrative examples.

  • PDF

Case Study of Geogrid Reinforcement in Runway of Inchon International Airport (지오그리드를 활용한 인천국제공항 활주로 보강사례)

  • 신은철;오영인;이규진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.105-116
    • /
    • 1999
  • The Inchon International Airport site was formed by reclaimed soil from the sea. The average thickness of soft soil Is about 5 m and most of soft soils are normally consolidated or slightly over consolidated. There are many box culverts which are being constructed under the runways in the airfield. Sometimes, differential settlement can be occurred in the adjacent of box culvert or underground structures at the top layer of runway Soil compaction at very near to the structure is not easy all the time. Thus, one layer of geogrid was placed at the bottom of lean concrete layer for the concrete paved runway and at the middle of cement stabilized sub-base course layer for the asphalt paved runway. The length of geogrid reinforcement is 5m from the end of box culvert for both sides. The extended length of geogrid was 2m from the end of backfill soil in the box culvert. The tensile strength tests of geogrid were conducted for make sure the chemical compatibility with cement treated sub-base material. The location of geogrid placement for the concrete paved runway was evaluated. The construction damage to the geogrid could be occurred. Because the cement treated sub-base layer or lean concrete was spread by the finisher. The magnitude of tensile strength reduction was 1.16%~1.90% due to the construction damage and the ultimate tensile strength is maintained with the specification required. Total area of geogrid placement in this project is about 50,000 $m^2$.

  • PDF

Effects of Human Trampling Disturbance on the Vegetation at the Subalpine Zone near the Peak of Mt. Sorak, Korea (답압이 설악산 아고산대의 식생에 미치는 영향)

  • 이규송;최오길;김석철
    • The Korean Journal of Ecology
    • /
    • v.25 no.5
    • /
    • pp.321-328
    • /
    • 2002
  • In order to provide the basic information for restoration of vegetation, conservation of rare species and maintenance of biodiversity, changes of site factors and vegetation by human trampling disturbance were investigated at the subalpine zone near the peak of Mt. Sorak in Korea. The destructed vegetation was found mainly in the southern parts with gentle slope in this study area. Height and coverage of vegetation and the species diversity decreased, and the community structure depended on trampling strength. Soil moisture, organic matter contents and litter thickness in the site with destructed vegetation by human trampling showed lower values than in the undisturbed site. Soil depth decreased, and gravel exposure on the ground surface increased by soil erosion responded to trampling strength.

Stability assessment of tunnel face in a layered soil using upper bound theorem of limit analysis

  • Khezri, Nima;Mohamad, Hisham;Fatahi, Behzad
    • Geomechanics and Engineering
    • /
    • v.11 no.4
    • /
    • pp.471-492
    • /
    • 2016
  • Underground tunnelling is one of the sustainable construction methods which can facilitate the increasing passenger transportation in the urban areas and benefit the community in the long term. Tunnelling in various ground conditions requires careful consideration of the stability factor. This paper investigates three dimensional stability of a shallow circular tunnel in a layered soil. Upper bound theorem of limit analysis was utilised to solve the tunnel face stability problem. A three dimensional kinematic admissible failure mechanism was improved to model a layered soil and limiting assumptions of the previous studies were resolved. The study includes calculation of the minimum support pressure acting on the face of the excavation in closed-face excavations. The effects of the characteristics of the layers on the minimum support pressure were examined. It was found that the ratio of the thickness of cover layers particularly when a weak layer is overlying a stronger layer, has the most significant influence on the minimum tunnel support pressure. Comparisons have been made with the results of the numerical modelling using FLAC3D software. Results of the current study were in a remarkable agreement with those of numerical modelling.