• Title/Summary/Keyword: soil model

Search Result 4,496, Processing Time 0.03 seconds

Risk Assessment of Soil Erosion in Gyeongju Using RUSLE Method (RUSLE 기법을 이용한 경주지역의 토양침식 위험도 평가)

  • Oh, Jeong-Hak;You, Ju-Han;Kim, Kyung-Tae;Lee, Woo-Sung
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.3
    • /
    • pp.313-324
    • /
    • 2011
  • The purpose of this study is to present the raw data for establishing the plan of top soil conservation in soil environment and preventing the soil loss by establishing the potential amount of soil loss using RUSLE. The results are as follows. To apply the RUSLE model, we calculated the potential amount of soil loss by using 5 factors; rainfall erosion factor(R), topographical factor(LS), soil erosion factor(K), land cover factor(C) and erosion control factor(P). The assessment map of soil loss was drawn up by classifying 5 grades. According to the soil loss estimation by the RUSLE, it showed that approximately 83.9% of the study area had relatively lower possibility of soil loss which was the 1 ton/ha in annual soil loss. Whereas, the 7.0% of the study area was defined as high risk area which was the 10 ton/ha in annual. Therefore, this area was needed that there was environment-friendly construction of farm land, improvement of cultivation environment and so forth. In future, if we will analyze the amount of soil loss of Gyeongju national park and Hyeongsan river watershed, we will offer the help to establishing the conservation plan of soil environment in Gyeongsangbuk-do.

Soil Arching in Embarikments Suppoyed by Piles with Geosynthethics (말뚝과 토목섬유로 지지된 성토지반의 아칭효과)

  • Hong, Won-Pyo;Lee, Jae-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.6
    • /
    • pp.53-66
    • /
    • 2007
  • A series of model tests were performed to investigate the soil arching effect in embankments supported by piles with geosynthetics. In the model tests, model piles with isolated cap were inserted through the holes in a steel plate, which could be operated up and down. Then geosynthetics was laid on the pile caps below sand fills. The settlement of soft ground was simulated by lowering the plate. As the plate was lowered, the soil arching was mobilized in the embankments. The deformation of both the sand fills and geosynthetics were captured by camera. Also the loads acting on pile cap and the tensile strain of geosynthetics were monitored by data logging system. Model tests showed that the embankment loads transferred on pile cap by soil arching Increased rapidly with settlement of the soft ground. In case of the absence of geosynthetics, the loads acting on pile caps dropped to residual value after peak value, whereas loads on pile caps gradually increased until constant value in case of geosynthetic-reinforced. This illustrated that reinforcing with the geosynthetics has a good effect to restrain the settlement of embankments. Also, the deformation shape of geosynthetics between pile caps was circular. The embankment loads transferred on pile caps can be estimated by considering both soil arching and tensile strain of geosynthetics in embankments supported by piles with geosynthetics.

Stochastic Continuous Storage Function Model with Ensemble Kalman Filtering (I) : Model Development (앙상블 칼만필터를 연계한 추계학적 연속형 저류함수모형 (I) : - 모형 개발 -)

  • Bae, Deg-Hyo;Lee, Byong-Ju;Georgakakos, Konstantine P.
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.11
    • /
    • pp.953-961
    • /
    • 2009
  • The objective of this study is to develop a stochastic continuous storage function model for enhancement of an event-oriented watershed and channel storage function models which have been used as an official flood forecast model in Korea. For this study, soil moisture accounting component is added to the original storage function model and each hydrologic component, such as surface flow, subsurface flow, groundwater flow and actual evaportranspiration, is simulated as a function of soil water content. And also, ensemble Kalman filtering technique is used for real-time assimilation of measured streamflow from various stream locations in the watershed. Therefore the enhanced model will be able to simulate hydrologic components for long-term period without additional estimation of model parameters and to give more accurate and reliable results than those from the existing deterministic model due to the assimilation of measured streamflow data.

A Two Mobilized-Plane Model for Soil Liquefaction Analysis (액상화해석을 위한 두 개의 활성면을 가진 구성모델)

  • Park, Sung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.173-181
    • /
    • 2006
  • A Two Mobilized-Plane Model is proposed for monotonic and cyclic soil response including liquefaction. This model is based on two mobilized planes: a plane of maximum shear stress, which rotates, and a horizontal plane which is spatially fixed. By controlling two mobilized planes, the model can simulate the principal stress rotation effect associated with simple shear from different $K_0$ states. The proposed model gives a similar skeleton behaviour for soils having the same mean stress, regardless of $K_0$ conditions as observed in laboratory tests. The soil skeleton behaviour observed in cyclic drained simple shear tests, including compaction during unloading and dilation at large strain is captured in the model. Undrained monotonic and cyclic response is predicted by imposing the volumetric constraint of the water on the drained or skeleton behaviour. This constitutive model is incorporated into the dynamic coupled stress-flow finite difference program of FLAC (Fast Lagrangian Analysis of Continua). The model was first calibrated with drained simple shear tests on Fraser River sand, and verified by comparing predicted and measured undrained behaviour of Fraser River sand using the same input parameters.

Effects of Artificial Substrate Type, Soil Depth, and Drainage Type on the Growth of Sedum sarmentosum Grown in a Shallow Green Rooftop System (저토심 옥상녹화 시스템에서 돌나물(Sedum sarmentosum)의 생육에 대한 인공배지 종류, 토심, 그리고 배수 형태의 효과)

  • 허근영;김인혜;강호철
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.102-112
    • /
    • 2003
  • This study was carried out to research and develop a shallow green rooftop system which would require low maintenance and therefore could be used for existing rooftops. To achieve these goals, the conceptual model was induced by past studies and the experimental systems were deduced from the conceptual model. On the growth of Sedum sarmentosum grown in these rooftop systems, the effects of artificial substrate type, soil depth, and drainage type were investigated from 3 April to 11 October 2002. Artificial substrates were an alone type and a blending type. The alone type was an artificial substrate formulated by blending crushed porous glass with bark(v/v, 6:4). The blending type was formulated by blending the alone type with loam(v/v, 1:1). Soil depths were 5cm, loom, and 15cm. Drainage types were a reservoir-drainage type and a drainage type. The reservoir-drainage type could keep water and drain excessive water at the same time. The drainage type could drain excessive water but could not keep water. Covering area, total fresh and dry weight, visual quality, and water content per 1g dry matter were measured. All the variables were analyzed by correlation analysis and factor analysis. The results of the study are summarized as follows. The growth increment was higher in the blending type than in the alone type, the highest in loom soil depth and higher in the reservoir-drainage type than in the drainage type. The growth quality was higher in the blending type than in the alone type, the highest in l0cm soil depth, and higher in the drainage type than in the reservoir-drainage type. In consideration of the permissible load on the existing rooftops and the effects of the treatments on the growth increment and quality, the system should adopt the blending type in artificial substrate types, 5~10cm in soil depths, and the drainage type in drainage types. This system will be well-suited to the growth of Sedum sarmentosum, and when the artificial substrate was in field capacity, the weight will be 75~115kg/$m^2$.

The Estimation of Water Balance at Regional Upland According to RCP8.5 Scenario from 2011 to 2020

  • Shin, Kook-Sik;Cho, Hyun-Sook;Seong, Ki-Young;Park, Tae-Seon;Kang, Hang-Won;Seo, Myung-Chul
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.1
    • /
    • pp.48-58
    • /
    • 2014
  • In order to evaluate water balance at upland according to RCP8.5 climate change scenario distributed by Korean Meteorological Administration (KMA), we simulated soil moisture using estimation model, called AFKAE0.5 for 66 sites from 2011 to 2020, and established the water balance maps. The amount of annual average precipitation by RCP8.5 scenario was highest in 2016 as recorded 2,062 mm and lowest in 2011 with 1,134 mm. As result of analysis for monthly precipitation and runoff, the amounts of precipitation and runoff have been especially intensive in July in 2014, 2016, 2019, and 2020. Overall, the area of Kyeongbuk and Gyeonggi was estimated more dried status of soil compared with precipitation. Except 2015 and 2020, soil water balance was recorded as negative value in other years which was calculated by subtracting output from input. The status of soil moisture was the most dry in 2020 among those in other years.

Numerical Calculation for Impedance of Horizontal Ground Electrode for Information and Communication Facilities with Considering Characteristics of Permittivity in Soil (토양의 유전율 특성을 고려한 정보통신설비용 수평접지전극의 임피던스 계산)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.245-251
    • /
    • 2013
  • An impedance of ground electrode for information and communication facilities has a significant relationship with the electrical characteristics of soil where the ground electrode is buried. Especially, the impedance of ground electrode is directly affected by the characteristics of permittivity and conductivity in soil as a function of a frequency of an applied electric field. The program based on the electromagnetic field model was developed in MATLAB. Because both permittivity and conductivity can not be modified in commercial programs. The permittivity of soil was applied with the Debye equation which is a model of dielectric relaxation. And the empirical equation of the conductivity in soil was quoted in other paper. In order to confirm the reliability of proposed program, the impedance measurement of ground electrode was carried out, which were compared with the results of simulation in commercial program. In result, it was confirmed that the impedance and phase different simulated by appling the characteristics of permittivity and conductivity in soil are in good agreement with the measured values than results of NEC.

Modeling of the Tensile Strength of Unsaturated Granular Soil Using Soil-water Characteristic Curve (흙-수분 특성 곡선을 이용한 불포화모래의 인장강도 모델링)

  • Kim Tae-Hyung;Kim Chan-Kee;Kim Tae-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.171-181
    • /
    • 2004
  • This study was conducted to explore the tensile strength models in granular soil at the full range of unsaturated state. Direct tension experiments were carried out with a newly developed direct tension technique. The measured experimental data were compared with theoretical models developed by Rumpf and Schubert for monosized ideal particulate solids at the unsaturated state. To do this, the soil-water characteristic curve obtained from a suction-saturation experiment was used to define the unsaturation state and the negative pore water pressure with different water content levels, which are important factors in theoretical tensile strength models. The nonlinear behavior of the tensile strength for unsaturated granular soil at the pendular state is appropriately simulated with Rumpf's model. For the funicular and capillary states, the predicted trend by Schubert's model is properly matched with the experimental data: tensile strength steadily increases and reaches a maximum value and then decreases until it reaches zero. This comparison supports the concept that the tensile strength of unsaturated real granular soil can be approximately simulated with theoretical models.

Stress-strain Behavior of Sand Reinforced with Geocell (지오셀로 보강된 모래의 응력-변형 거동)

  • Yoon, Yeo-Won;Kim, Jae-Youn;Kim, Bang-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.2
    • /
    • pp.27-37
    • /
    • 2003
  • In this research stress-strain behavior of composite geocell-soil systems under triaxial condition and the influence of strength due to the presence of geocell were studied. For the research a series of triaxial tests were carried out on sand specimens confined by flexible-walled single rubber cell. The diameter of all rubber cells placed at the center of the soil sample were 50 mm. Three rubber sizes, i.e. 35, 50 and 70 mm height, were applied to the soil specimen and the size of soil specimen was 50 mm in diameter and 100 mm in height. Three different densities of soil were used for the tests. In general, it was observed that the sand specimen develops an apparent cohesion due to the confinement by the geocell. The magnitude of this cohesion seemed to be dependent to the properties of the geocell material. The test results have shown that the geocell material for this research not only develops the apparent cohesion but also increases the angle of friction whereas geosynthetic material in the references showed only the increase of apparent cohesion. From the application of geocell-soil composites to the hyperbolic model, it was recognized that the determination of the peak strength influences the behavior of the geocell-soil composites.

  • PDF

A scientific approach to estimate the safe depth of burial of submarine pipelines against wave forces for different marine soil conditions

  • Neelamani, S.;Al-Banaa, K.
    • Ocean Systems Engineering
    • /
    • v.3 no.1
    • /
    • pp.9-34
    • /
    • 2013
  • Submarine pipelines encounter significant wave forces in shallow coastal waters due to the action of waves. In order to reduce such forces (also to protect the pipe against anchors and dropped objects) they are buried below the seabed. The wave force variation due to burial depends on the engineering characteristics of the sub soil like hydraulic conductivity and porosity, apart from the design environmental conditions. For a given wave condition, in certain type of soil, the wave force can reduce drastically with increased burial and in certain other type of soil, it may not. It is hence essential to understand how the wave forces vary in soils of different hydraulic conductivity. Based on physical model study, the wave forces on the buried pipeline model is assessed for a wide range of wave conditions, for different burial depths and for four types of cohesion-less soils, covering hydraulic conductivity in the range of 0.286 to 1.84 mm/s. It is found that for all the four soil types, the horizontal wave force reduces with increase in depth of burial, whereas the vertical force is high for half buried condition. Among the soils, well graded one is better for half buried case, since the least vertical force is experienced for this situation. It is found that uniformly graded and low hydraulic conductivity soil attracts the maximum vertical force for half buried case. A case study analysis is carried out and is reported. The results of this study are useful for submarine buried pipeline design.