• Title/Summary/Keyword: soil model

Search Result 4,496, Processing Time 0.036 seconds

Pullout Characteristics of Multi Helical Anchors in Clay (점성토 지반에서의 다중 헬리컬 앵커의 인발 특성)

  • 이준대;이봉직;이종규
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.114-121
    • /
    • 1997
  • Helical anchors are foundation structure that designed to resist uplift loads are installed by applying in load to shaft while rotating it into the ground. These can be a cost effective means of proving tension anchorage for foundation where soil conditions permit their installation because of ease of installation. At present time, tapered helical anchors are commonly used to carry uplift loads. The uplift capacity includes the following factors : the height of overburden above the top helix, the resistant along a cylinder, the weight of the soil in the cylinder and suction force. In order to make clear behavior characteristics of helical anchors with pullout, model tests were conducted with respect to various embedment depth, space of helix, shape of helix. Based on the experimental study, the following conclusions are drawn. 1) The uplift capacity of multi helical anchors increase with embedment ratio of anchors The increase is smooth after critical uplift capacity. 2) Critical breakout factors and critical embedment ratio of multi helical anchor exist 7∼8, 4∼6 respectively. 3) Variation of uplift capacity with helix spaces show down after S/D=5. 4) Critical breakout factors of helical anchor in the laboratory test are similar to Das's theory.

  • PDF

Stability and Vibration of Non-Uniform Timoshenko Beams resting on Two-Parameter Elastic Foundations (두 파라메타 탄성기초위에 놓인 불균일 Timoshenko보의 안정성과 진동)

  • Lee, Jong-Won;Ryu, Bong-Jo;Lee, Gyu-Seop;Kong, Yong-Sik;Oh, Bu-Jin
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.596-601
    • /
    • 2000
  • The paper presents free vibration and stability analyses of a non-uniform Timoshenko beam resting on a two-parameter elastic soil. The soil parameters can vary along the spat and is assumed to be two-parameter model including the effects of both transverse shear deformation and elastic foundation Governing equations related to the vibration and the stability of the beam are derived from Hamilton's principle, and the resulting eigen-value problems can be solved to give natural frequencies and critical force by finite element method. Numerical results for both vibration and stability of beams under an axial force are presented and compared with other available solutions. Finally, vibration frequencies, mode shapes and critical forces are investigated for various thickness ratios, shear foundation parameter, Winkler foundation parameter and boundary conditions of tapered Timoshenko beams.

  • PDF

System identification of the suspension tower of Runyang Bridge based on ambient vibration tests

  • Li, Zhijun;Feng, Dongming;Feng, Maria Q.;Xu, Xiuli
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.523-538
    • /
    • 2017
  • A series of field vibration tests are conducted on the Runyang Suspension Bridge during both the construction and operational stages. The purpose of this study is devoted to the analysis of the dynamic characteristics of the suspension tower. After the tower was erected, an array of accelerometers was deployed to study the evolution of its modal parameters during the construction process. Dynamic tests were first performed under the freestanding tower condition and then under the tower-cable condition after the superstructure was installed. Based on the identified modal parameters, the effect of the pile-soil-structure interaction on dynamic characteristics of the suspension tower is investigated. Moreover, the stiffness of the pile foundation is successfully identified using a probabilistic finite model updating method. Furthermore, challenges of identifying the dynamic properties of the tower from the coupled responses of the tower-cable system are discussed in detail. It's found that compared with the identified results from the freestanding tower, the longitudinal and torsional natural frequencies of the tower in the tower-cable system have changed significantly, while the lateral mode frequencies change slightly. The identified modal results from measurements by the structural health monitoring system further confirmed that the vibrations of the bridge subsystems (i.e., the tower, the suspended deck and the main cable) are strongly coupled with one another.

Numerical evaluation of buried composite and steel pipe structures under the effects of gravity

  • Toh, William;Tan, Long Bin;Tse, Kwong Ming;Raju, Karthikayen;Lee, Heow Pueh;Tan, Vincent Beng Chye
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • In this paper, the response of an underground fibreglass reinforced plastic (FRP) composite pipe system subjected to realistic loading scenarios that may be experienced by an actual buried pipeline is investigated. The model replicates an arbitrary site with a length of buried pipeline, passing through a $90^{\circ}$ bend and into a valve pit. Various loading conditions, which include effects of pipe pressurization, differences in response between stainless steel and fibreglass composite pipes and severe loss of bed-soil support are studied. In addition to pipe response, the resulting soil stresses and ground settlement are also analysed. Furthermore, the locations of potential leakage and burst have also been identified by evaluating the contact pressures at the joints and by comparing stresses to the pipe hoop and axial failure strengths.

3D numerical investigation of segmental tunnels performance crossing a dip-slip fault

  • Zaheri, Milad;Ranjbarnia, Masoud;Dias, Daniel
    • Geomechanics and Engineering
    • /
    • v.23 no.4
    • /
    • pp.351-364
    • /
    • 2020
  • This paper numerically investigates the effects of a dip-slip fault (a normal or a reverse fault) movement on a segmental tunnel which transversely crosses either of this kind of faults. After calibration of the numerical model with results from literature of centrifuge physical tests, a parametric study is conducted to evaluate the effects of various parameters such as the granular soil properties, the fault dip angle, the segments thickness, and their connections stiffnesses on the tunnel performance. The results are presented and discussed in terms of the ground surface and tunnel displacements along the longitudinal axis for each case of faulting. The gradient of displacements and deformations of the tunnel cross section are also analyzed. It is shown that when the fault dip angle becomes greater, the tunnel and ground surface displacements are smaller, in the case of reverse faulting. For this type of fault offset, increasing the tunnel buried depth causes tunnel displacements as well as ground surface settlements to enhance which should be considered in the design.

Characterization of Local Evapotranspiration Based on the Seasonal and Hydrometeorological Conditions (계절과 수문기상학적 조건에 따른 지역 증발산의 특성화)

  • Rim, Chang-Soo;Lee, Jong-Tae;Yoon, Sei-Uei
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.235-247
    • /
    • 1996
  • Meteorological and soil water content data measured from semiarid watersheds of Lucky Hills and Kendall during the summer rainy and winter periods were used to study the interrelationships between the controlling variables of the evapotranspiration, and to evaluate the effects of variables on daily actual evapotranspiration (ET) estimation. Simple and multiple linear regression (MLR) analyses were employed to evaluate the order of importance of the meteorological and soil water factors involved. The information gained was used for MLR model development. Theavailable energy and vapor pressure deficit were found to be the important variables to estimate actual ET (AET) for both periods and at both watersheds. Therefore, the important variables of evapotranspiration process in these semiarid watersheds appear to be simply the components of energy term in available energy and aerodynamic term in vapor pressure deficit of Penman potential evapotranspiration (PET) equation.

  • PDF

Hydro-thermal Numerical Simulation for an Artificial Recharge Test in a Fractured Rock Aquifer (암반대수층 지하수 인공함양 시험에 대한 열-수리 모델링)

  • Park, Daehee;Koo, Min-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • An artificial recharge test aimed at investigating transport characteristics of the injected water plume in a fractured rock aquifer was conducted. The test used an injection well for injecting tap water whose temperature and electrical conductivity were different from the groundwater. Temporal and depth-wise variation of temperature and electrical conductivity was monitored in both the injection well and a nearby observation well. A highly permeable fracture zone acting as the major pathway of groundwater flow was distinctively revealed in the monitoring data. A finite element subsurface flow and transport simulator (FEFLOW) was used to investigate sensitivity of the transport process to associated aquifer parameters. Simulated results showed that aperture thickness of the fracture and the hydraulic gradient of groundwater highly affected spatio-temporal variation of temperature and electrical conductivity of the injected water plume. The study suggests that artificial recharge of colder water in a fractured rock aquifer could create a thermal plume persistent over a long period of time depending on hydro-thermal properties of the aquifer as well as the amount of injected water.

Characteristic Analysis of the Coefficient of Initial Abstraction and Development of its Formular in the Rural Watersheds - for the Small-Medium Watersheds in the Geum and Sapkyo River - (농촌유역에서의 초기강우손실 특성분석과 계수 산정식 개발 - 금강.삽교천 중소유역을 중심으로-)

  • Kim, Tai-Cheol;Lee, Jeong-Seon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.6
    • /
    • pp.3-12
    • /
    • 2008
  • It is important to estimate accurate effective rainfall to analyse flood flow and long-term runoff for the rational planning, design, and management of water resource. The initial abstraction is also important to estimate effective rainfall. The Soil Conservation Service (SCS) has developed a procedure and it has been most commonly applied to estimate effective rainfall. But the SCS method still has weak points, because of unnatural assumptions such as antecedent moisture conditions and initial abstraction. The coefficient of initial abstraction(K) is depending on the soil moisture condition and antecedent rainfall. The maximum storage capacity of Umax which is calibrated by stream flow data in the proposed watershed was derived from the DAWAST(DAily WAtershed STreamflow) model. The values of K obtained from 69 storm events at the five watersheds are ranging from 0.133 to 0.365 and its mean value is 0.207. Effective rainfall could be estimated more reasonably by introducing new concept of initial abstraction. The equation of $K=0.076Sa^{0.255}$ was recommended instead of 0.2 and it could be applicable to the small-medium rural watersheds.

The Dispersion Stability of $\alpha-Fe_2O_3$ Particulate Soil in the Anionic/Nonionic Mixed Surfactant Solution (음/비이온계 혼합계면활성제 용액에서 $\alpha-Fe_2O_3$ 입자의 분산안정성)

  • 정선영;강인숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.6
    • /
    • pp.854-861
    • /
    • 2004
  • To estimate dispersion stability of particles in anionic and nonionic surfactant mixed solution, suspending power was examined as functions of duration time of suspension, ionic and nonionic surfactant mixed ratio, surfactant concentration, kinds of electrolyte, ionic strength and mole numbers of oxyethylene additions to nonionic surfactant using $\alpha$-Fe$_2$O$_3$ particle as the model of particulate soil. The suspending power of anionic and nonionic surfactant mixed solution was relatively higher than that of anionic and nonionic surfactant single solution regardless of solution concentration. The suspending power was gradually decreased with increasing duration time of suspension. In the absence of electrolyte, the effect of surfactant concentration on suspending power was small but in solution with electrolyte, suspending power was lowest at 1 % surfactant concentration. With 1${\times}$10$^{-3}$ ionic strength and polyanionic electrolyte in solution, the suspending power was high but effects of oxyethylene mole number to nonionic surfactant on suspending power was small. Generally the suspending power was gradually increased with decreasing the particle size. Hence the suspending power was inversely related to the particle size.

Development of analysis technique of landslide hazards in natural slopes (자연사면 산사태재해 해석기법 개발)

  • Kim, Kyeong-Su;Song, Young-Suk;Cho, Yong-Chan;Chae, Byung-Gon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1092-1099
    • /
    • 2009
  • Landslide researches are divided to a method of interrelationship for various factors, method of predicting landslide possibility, and method of estimating landslide risk which are occurring landslides in the natural slope. Most of landslides occurred in natural slope are caused by a heavy rainfall in summer season. Weathered soil layer located in upper side of rock mass was occurred. As well as, they are announced to have an influence to geometry, geology, soil characteristics, and precipitation in the natural slope. In order to investigate and interpret the variety of landslides from field investigation to risk analysis, landslide analysis process due to geotechnical and geological opinions are systematically demanded. In this research, the study area is located in Macheon area, Gyeongsangnam-do and performed the landslide investigation. From the results of landslide investigation and analysis, optimized standard model based on natural landslide is proposed to high technical method of landslide investigation and interpretation.

  • PDF