A study on oil-contaminated fingerprints developing (유지문 현출법에 관한 연구)

  • Choi, Mi-Jung;Park, Won-Seok;Kim, Man-Ki;Jeon, Chung-Hyun;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • In general, three types of fingerprints could be found at the crime scene: visible, plastic, and latent fingerprints. Examples of visible fingerprint include those made by blood, paint or ink. Plastic fingerprint are made from an impression of the finger on soft material as soap, wax, etc. Latent fingerprint are those of the invisible one to the human eye. Oil-contaminated fingerprints remained in the evidence, that are contaminated with the soybean oil, engine oil, lubricating oil or grease. Oil-contaminated fingerprints are special types of fingerprint evidence but the research for developing method regarding oil-contaminated fingerprints is a few. In this study, ultraviolet light source was employed for untreated oil-contaminated prints and the freeze-dry method with liquid nitrogen for freeze oil residue on the surfaces with sequence of developing oil-contaminated fingerprints with black and magnetic powders, cyanoacrylate (CA) fuming, Basic Yellow 40. The types of oil chosen for the experiment were soybean oil, LSA oil, engine oil and material surfaces selected for the experiment were glass, plastic aluminum plates. The aims of this study were to determine the appropriate developing methods for oil-contaminated fingerprints.

Primary Non-Hodgkin's Lymphomas Presenting with Extradural Spinal Cord Compression as the Initial Manifestation (초기 증상으로 척수 압박 증세를 보인 원발성 Non-Hodgkin 임파종)

  • Kim, Se Hoon;Lim, Dong Jun;Cho, Tai Hyoung;Park, Jung Yul;Chung, Yong Gu;Lee, Hoon Kap;Lee, Ki Chan;Suh, Jung Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.10
    • /
    • pp.1365-1371
    • /
    • 2000
  • Objectives : Spinal cord compression is a rare presentation of non-Hodgkin's lymphoma(NHL), occurring in 0.1% to 10.2% of patients. Primary spinal extradural NHL, i.e. occurring in the absence of any detectable extraspinal lymphoproliferative disorder, has a potentially favourable outcome if diagnosed and treated early. The authors describe two patients with a clinical picture of acute spinal cord compression as the first presentation of NHL. Methods : The patients were 48-year-old female and 27-year-old female. Both presented with back pain followed by acute paraparesis and voiding difficulty. One patient was diabetic. Plain radiographs of the spine were not specific. Thoracic spine magnetic resonance imaging(MRI) revealed evidence of extradural soft tissue mass extending multiple vertebral segments. Results : The patients underwent emergency laminectomy for decompression and tissue diagnosis. Histological and immunohistochemical study revealed B-cell lymphoma, intermediate grade in both patients. Postoperative staging did not reveal any additional lesions other than extradural manifestation of the malignant lymphoma. Surgery with additional chemotherapy and radiotherapy allowed the clinical improvement of both patients. Conclusion : The authors report two patients with a clinical picture of acute spinal cord compression as the first presentation of NHL, and stress that primary spinal epidural NHL should be a diagnostic consideration in the patient without prior history of malignancy who presents with a prodrome of back pain followed by a rapid neurological deterioration.

  • PDF

Complete Rupture of the Origins of Rectus Femoris Occurred During Relay Race - A Case Report - (릴레이 경주 중에 발생한 대퇴직근 기시부의 완전 파열 - 증례보고 -)

  • Jeon, Seung-Ju;Jeon, Ho-Seung;Moon, Chan-Sam;Noh, Haeng-Kee;Ha, Seung-Joo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.151-155
    • /
    • 2008
  • During sports activity, rectus femoris muscle can be commonly injured as the quadriceps contracts forcefully to extend the knee and flex the hip, and rectus femoris muscle has a high percentage of type II muscle fibers which enable it to produce rapid forceful activity and the muscle is the only biarticular muscle of the quadriceps. Avulsion fractures by the traction of rectus femoris from the anterior inferior iliac spine in children are often reported. Rarely, complete rupture of proximal musculotendinous junction of rectus femoris muscle in adult may occurs by chronic repetitive stimulation and may mimic soft tissue neoplasm in the case of no history of antecedent trauma. However, there has been no report of acute complete rupture of origins of the rectus femoris muscle during relay race till now. So, we report a case of acute complete rupture of origins of the rectus femoris muscle occurred during relay race in middle-aged man, diagnosed by magnetic resonance image and treated by surgical repair with review of current literature.

  • PDF

Comparative Study between MRI and pain, duration, physical examination in 20 patients with knee joint pain (20례 슬통환자의 통증, 이환기간, 물리적 검사법과 MRI소견과의 비교 고찰)

  • Yang, Myung-bok;Jang, Byung-sun;Lee, Dae-yong;Lee, Seung-hoon;Hwang, Byung-chun;Park, Jung-un;Guk, Ui-suk;Lee, Geon-mok
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.221-233
    • /
    • 2002
  • Background and Purpose : MRI(Magnetic Resonance Imaging) has become one of the most sensitive diagnostic tool no evaluate problems of the knee, because it enables us to identify not only osseous tissue but also soft tissues including muscle, fascia, tendon, ligament, meniscus and fat around the knee joint. Objective : To compare between MRI reading and pain, duration, physical examination in patients with pain of knee joint. Methods : 20 patients with pain of knee joint included in this study. This study researched pain-degree, duration, physical examination with pain of knee joint. Using MRI(Horizon Lx 1.0T-GE), we obtained the results. Results : 1. In the distribution of sex; Female rate was 80.0% and male rate was 20.0%. In the distribution of age, above sixty group was the largest group by each 55.0%. 2. In the distribution of MRI reading; 'Meniscus horm tear' was 70.0%, 'Osteoarthritis' was 55.5%, 'ACL partial tear' was 15.0%, 'Bone bruise at tibia, femur' was 15.0%. 3. Correlation between duration of pain and MRI reading showed that acute and subacute stage related various MRI reading, that chronic stage related 'Osteoarthritis' and 'Meniscus horn tear' by each 69.2%, 92.3%. 4. Correlation between pain and MRI reading showed that severe pain(GVI) related 'ACL partial tear, PCL partial tear' by each 100%, that mild pain(GII) related 'Osteoarthritis, Meniscus horn tear' by each 70.0%, 80.0%. 5. Correlation between physical examination and MRI reading showed that Drawer test related ACL partial tear by each 60.0%, that McMurray test related 'Meniscus horn tear' by each 75.0%. 6. Correlation between effect of treatment and MRI reading showed that 'Osteoarthritis, Meniscus horn tear' related good effect, that ACL partial tear related poor effect. Conclusions : These results suggest that acute and sever pain relate 'ACL partial tear, PCL partial tear', that chronic and mild pain related 'Osteoarthritis, Meniscus horn tear'. So it is responsibility to use MRI as a sensitive diagnostic tool in the knee problems.

  • PDF

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.07a
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

Removal of PVC from Mixed Plastic Waste by Combination of Air Classification and Centrifugal Process (풍력(風力) 및 습식비중(濕式比重) 선별(選別)에 의한 혼합(混合)폐플라스틱 종말품(終末品)으로부터 PVC 제거(除去)에 관한 연구(硏究))

  • Choi, Woo-Zin;Yoo, Jae-Myung
    • Resources Recycling
    • /
    • v.16 no.5
    • /
    • pp.71-76
    • /
    • 2007
  • The mixed plastic waste generated from households after hand-picking and/or mechanical sorting processes amounts to 1,750,000 ton in 2006, and most of these waste are finally end up with landfill and/or incineration due to the lacks of separation technologies and economical reasons. The mixed plastic wastes can not be used as raw materials for chemical and/or thermal recycling processes because of their high content of PVC(upto 4.0 wt.%). In the present research, gravity separation system has been developed to remove PVC from the mixed plastic waste and to recover the PO-type plastics. This system mainly consists of air classification, magnetic separation, one-step crushing, feeding system at fixed rate and wet-type gravity separation system. The gravity system based on centrifugal separation has been developed at capacity of 0.5 ton/h and it consists of mixing, precleaning, separation, dewatering, recovery system and wastewater treatment system, etc. The main objective of this process is to achieve high separation efficiency of polyolefins with less than 0.3 wt.% PVC content and less than 10% moisture content in the final products. In addition, a crushing unit of with 8 rotor system is also developed to improve the crushing efficiency of soft-type plastics. The system with a capacity of 1.0 ton/h is developed and operational results are presented.

Magnetoresistance of $[FeNi/Cu/CoFe(Co)/Cu]_N$ Spin-Valve Multilayers ($[FeNi/Cu/CoFe(Co)/Cu]_N$ Spin-Valve 다층박막의 자기저항 특성)

  • 김미양;이정미;최규리;오미영;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 1999
  • $Buffer/[NiFe/Cu/CoFe(Co)/Cu]_N$ spin valve multilayers prepared by dc magnetron sputtering on a corning glass substrate using NiFe and CoFe(Co) posses different coercivities. Dependence of magnetoresistance on the type and thickness of buffer layer, thickness of Cu, NiFe, stacking number of multilayer, substrate temperature and annealing temperature in the form $[NiFe/Cu/CoFe(Co)/Cu]_N$ spin-valve multilayers were investigated. To evaluate effect of magnetoresistance for this samples, X-ray diffraction analysis, vibrating sample magnetometer analysis, and magnetoresistance measurement (4-probe method) were performed the maximum magnetoresistance ratio and coercivity were 7.5 % and 140 Oe, respectively for $Cr-50{\AA}/[NiFe-20{\AA}/Cu-{\AA}/Co-20{\AA}/Cu-50{\AA}]_10$ at substrate temperature of 9$0^{\circ}C$. Magnetoresistance slope maintained 0.25%/Oe until 15$0^{\circ}C$ of annealing temperature, and then decreased to 0.03%/Oe at 20$0^{\circ}C$. It was confirmed that the main factor of thermal stability was deteriorating of soft magnetic properties in the NiFe layer.

  • PDF

IgG4-related Ophthalmic Disease Associated with Adult Xanthogranulomatous Disease (황색육아종과 동반된 면역글로불린G4관련안질환 1예)

  • Lee, Seunghyun;Chung, Sokjoong;Heo, Jinhyung;Lew, Helen
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1071-1076
    • /
    • 2018
  • Purpose: To report a case of immunoglobulin G4 (IgG4)-related ophthalmic disease associated with adult xanthogranulomatous disease. Case summary: A 38-year-old male with a history of cholecystectomy visited our clinic for bilateral periorbital swelling. Histopathology of the orbital biopsy showed diffuse infiltration of foamy histiocytes with Touton giant cells and lymphoid follicles, with a diagnosis of adult-onset xanthogranuloma. After excisional biopsy, he was treated with azathioprine and prednisolone. Four years after treatment, he again visited the clinic due to bilateral, yellowish eyelid masses. Serological examinations were all nonspecific findings, except for elevation of IgG and IgG4 levels. Magnetic resonance imaging showed bilateral symmetric soft tissue enlargement with slightly heterogeneous T1/T2 isosignal intensity, with contrast enhancement at the superolateral aspect of extraconal spaces. Excisional biopsy and blepharoplasty were performed. Immunohistochemical sections showed that the IgG4+/IgG plasma cell ratio was 10-20% and the IgG4 plasma cell count was 22/high power field (HPF). His past sections of 2013 from the pathology department were again stained and showed that the IgG4+/IgG plasma cell ratio was 40-50% and the IgG4 plasma cell count was 59/HPF. Thus, he was definitely diagnosed with IgG4-related ophthalmic disease. Conclusions: If there is recurrent eyelid swelling, IgG4-related ophthalmic disease should be considered as a differential diagnosis. And the patient with adult xanthogranulomatous disease can be diagnosed with IgG4-related ophthalmic disease.

Pathophysiology and MRI Findings of Infectious Spondylitis and the Differential Diagnosis (감염성 척추염과 감별질환의 병태생리와 MRI 소견)

  • Sunjin Ryu;Yeo Ju Kim;Seunghun Lee;Jeongah Ryu;Sunghoon Park;Jung Ui Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1413-1440
    • /
    • 2021
  • On MRI, abnormal signals of the intervertebral disc, destruction of the upper and lower vertebral body endplate around the disc, and bone marrow edema around the endplate are considered typical findings of infectious spondylitis. These findings can also appear in various non-infectious spinal diseases, such as degenerative changes, acute Schmorl's node, spondyloarthropathy, synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO), chronic recurrent multifocal osteomyelitis, and calcium pyrophosphate dihydrate crystal deposition disease. The imaging findings of infectious spondylitis that can be differentiated from these non-infectious spinal diseases on MRI are high signal intensity and abscess of the disc space, an abscess in the paraspinal soft tissue, and the loss of the linear low signal intensity on T1-weighted images of the bony endplate. However, these differentiation points do not always apply since there are many similarities in the imaging findings of infectious and non-infectious diseases. Therefore, for an accurate diagnosis, it is important to know the imaging characteristics related to the pathophysiology of not only infectious spondylitis but also non-infectious spinal diseases, which requires differentiation from infection.

Dependency of Generator Performance on T1 and T2 weights of the Input MR Images in developing a CycleGan based CT image generator from MR images (CycleGan 딥러닝기반 인공CT영상 생성성능에 대한 입력 MR영상의 T1 및 T2 가중방식의 영향)

  • Samuel Lee;Jonghun Jeong;Jinyoung Kim;Yeon Soo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2024
  • Even though MR can reveal excellent soft-tissue contrast and functional information, CT is also required for electron density information for accurate dose calculation in Radiotherapy. For the fusion of MRI and CT images in RT treatment planning workflow, patients are normally scanned on both MRI and CT imaging modalities. Recently deep-learning-based generations of CT images from MR images became possible owing to machine learning technology. This eliminated CT scanning work. This study implemented a CycleGan deep-learning-based CT image generation from MR images. Three CT generators whose learning is based on T1- , T2- , or T1-&T2-weighted MR images were created, respectively. We found that the T1-weighted MR image-based generator can generate better than other CT generators when T1-weighted MR images are input. In contrast, a T2-weighted MR image-based generator can generate better than other CT generators do when T2-weighted MR images are input. The results say that the CT generator from MR images is just outside the practical clinics and the specific weight MR image-based machine-learning generator can generate better CT images than other sequence MR image-based generators do.