• 제목/요약/키워드: sodium lamp

검색결과 76건 처리시간 0.021초

고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지 (The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp)

  • 한태환;우천희
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

겨울철 보광이 절화장미 'Nobles'의 생육 및 개화에 미치는 영향 (Effect of Supplemental lighting on the Growth and Flowering of Rosa hybrida 'Nobles' in winter)

  • 나택상;김정근;최경주;기광연;유용권
    • 생물환경조절학회지
    • /
    • 제16권2호
    • /
    • pp.130-134
    • /
    • 2007
  • 본 시험은 겨울철 광원별 보광처리에 따른 장미의 생육장태와 온실내의 온 습도 변화를 조사하기 위하여 수행하였다. 보광재료는 나트륨등과 형광등을 사용하였고, 처리는 야간에 5시간씩 하였고, 2회 수확하였다. 온실 내 온도는 보광시작 후 나트륨 등 보광처리가 높았으며, 슬라브내 온도는 오전 6시에 나트륨등으로 보광한 처리가 높게 나타났으며, 일일 평균습도는 나트륨 등 처리가 낮게 나타났다. 나트륨 등 처리시 장미 줄기의 인산, 칼륨, 칼슘, 마그네슘 함량은 다른 처리보다 많았고, 잎에서는 칼륨과 마그네슘 함량이 다른 처리보다 낮았다. 잎의 엽록소 함량은 처리간 차이가 없었다. 절화장과 줄기 직경은 다른 처리보다 나트륨 등 처리에서 양호하였다. 수량은 2회 모두 나트륨 등 보광에서 더 많이 나와 일조량이 부족한 겨울철에 나트륨 등으로 보광하면 장미 수량과 품질을 높일 것으로 생각된다.

초정압방전램프(UCD)와 나트륨램프를 적용한 식물재배에 관한 연구 (A Study on the Plant Cultivation by comparing Ultra Constant Discharge (UCD) Lamp lighting and Hi-Pressure Sodium Lamp lighting)

  • 정풍기;김영철;양현수
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.31-40
    • /
    • 2011
  • This study was conducted to research how UCD(Ultra Constant Discharge) lamp lighting affects plant cultivation. To get the results within a short time, lettuce seedling was selected as a plant and nutrient hydroponic beds were used in a dark room for 100% artificial lighting. Two beds were installed for same distance lighting condition with UCD lamp and Hi-pressure Sodium lamp each and another two beds were installed for same light intensity condition with each type of lamp. After 15 days of cultivation, for both conditions, the yields under UCD lamp were weighed more than that under Hi-pressure Sodium lamp. The result can be analyzed that the spectrum of UCD lamp having near sunlight characteristic is much superior to that of Hi-pressure Sodium lamp having a line spectrum characteristic on yellow and red wavelengths for plant cultivation.

150W 고압나트륨램프용 전자식 안정기 개발 (Development of Electronic Ballast for 150W High Pressure Sodium Lamp)

  • 김순기;노재엽;이용후;최현배;이진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.107-110
    • /
    • 2000
  • This paper deals with the design of the electronic ballast for high pressure sodium lamp, which consists of the ignitor and the resonant converter for driving the lamp. Also it contains PFC(Power Factor Controller) to improve such as power factor, low distortion etc. In this paper, we design the electronic ballast for the 150 watt high pressure sodium lamp.

  • PDF

LabVIEW 소프트웨어 패키지를 이용한 고압나트륨전등의 교환시점 및 수명진단 알고리듬 (The Algorithm of Life Time Diagnostics end Evaluating of Exchanges Time about High Pressure Sodium Vapor Lamp Using the LabVIEW Software Package)

  • 한태환
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.1-7
    • /
    • 2004
  • 고압방전등을 점등하기 위해서는 고전압의 시동전압이 필요하게 되는데, 이러한 시동전압은 고압력의 나트륨램프에서도 필요하게 된다. 자기장은 전기 방전튜브에서 만들어지게 되며 증기 원자에 대한 전자충돌이 가속화되면서 2차 전자가 발생하고 전기 방전튜브에 전류가 급속도로 흐르게 되며, 나트륨램프의 제작회사마다. 서로 다른 램프의 수명 및 교환시점도 서로 다르다는 것을 본 논문의 연구과정에서 발견하게 되었다. 본 논문에서는 LabVIEW소프트웨어패키지를 사용 중인 나트륨램프의 교환시점의 알고리듬을 제안한다.

전자식 안정기를 위한 HID Lamp 시뮬레이션 모델 (A PSpice Model for the Electrical Ballast of HID Lamps)

  • 지윤근;김남준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.27-32
    • /
    • 2003
  • The thesis is used by PSpice circuit model to the characteristics of a fluorescent lamp modified form of he classical Cassie and Mayr equations in order to show the characteristics of HID(High-Intensity Discharge) Lamp. This is useful for applying high-frequency electric ballast for HID Lamp, and show that the result of experimentations and simulations, such as lamp rating, input voltage, high-frequency electric ballast which is using the ABM circuit model of the low pressure sodium lamp, come to the voltage and current wave.

고압나트륨램프에서 LED램프로 터널조명등 교체에 따른 전력사용량 및 조도변화 분석 (Analysis of power usage and illuminance changes due to the replacement of tunnel lighting source from high pressure sodium lamp to LED)

  • 이규필;김정흠
    • 한국터널지하공간학회 논문집
    • /
    • 제23권4호
    • /
    • pp.211-220
    • /
    • 2021
  • 터널구조물의 특성상 터널조명은 일반 도로의 조명과 달리 주간에도 조명이 필요하므로, 터널 유지관리 비용 가운데 터널조명을 위한 전력요금은 가장 높은 비율을 차지하고 있는 것으로 알려져 있다. 따라서 유지비용 절감 등을 위하여 터널조명을 낮은 소비전력, 장수명 등의 장점이 있는 LED램프로 교체 중에 있다. 본 연구에서는 기존 터널조명이 고압나트륨램프인 10개소 터널을 대상으로 터널조명 광원을 LED램프로 교체 시 효과 분석을 위하여, 광원 교체 전·후 터널 조도측정결과 및 1년간의 월별 전력사용량을 조사하였다. 터널조명 광원을 고압나트륨램프에서 LED램프로 교체 후 조도는 27.9~490% 향상되었으나, 터널조명용 전력사용량은 평균 47.1% 감소한 것으로 나타났다.

Electronic Ballast for HPS Lamps with Intrinsic Power Regulation over Lamp Life

  • Dehghani, Majid;Saghaiannejad, Seid Mortaza;Karshenas, Hamid Reza
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.526-534
    • /
    • 2009
  • This paper introduces the electronic ballast for high pressure sodium (HPS) lamps which provides power regulation during the whole lamp life without using a closed-loop power control system, in spite of large variations of lamp characteristics resulting from lamp aging. The structure of the electronic ballast and the parameters of HPS lamps are described. A mathematical model for the ballast is developed and used for the design and analysis of the ballast. A design procedure is presented to design the ballast which provides intrinsic power regulation over the whole lamp life. To improve the technical specifications of the ballast, the practical and standard constraints are considered in the design. According to the design procedure, an electronic ballast for 250-W HPS lamps is designed. All theoretical analyses are verified with the help of a semi-industrial experimental setup. The results validate that the designed ballast provides power regulation during the whole lamp life.

고효율 고압 나트륨램프용 자기식 안정기 (High Efficiency Magnetic Ballast for High Pressure Sodium Lamp)

  • 이진우;김순기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.99-102
    • /
    • 1999
  • The object of this paper is design and to make a high efficiency magnetic ballast for high pressure sodium lamp. The results show the efficiency is 10[%] up compared with standard ballast in best case.

  • PDF

터널 조명등 교체에 따른 전력사용량 및 조도 개선 효과: 저압나트륨램프 LED로 교체 (Effect of tunnel lighting replacement on power usage and illumination improvement: replacing low pressure sodium lamp with LED)

  • 이규필;김정흠
    • 한국터널지하공간학회 논문집
    • /
    • 제22권2호
    • /
    • pp.185-196
    • /
    • 2020
  • 국내 터널조명에는 저압나트륨램프, 고압나트륨램프, 형광램프 등이 주요 광원으로 사용되고 있으며, 터널 유지관리 비용 가운데 터널조명을 위한 전력요금은 가장 높은 비율을 차지하고 있는 것으로 알려져 있다. 따라서 터널조명은 낮은 소비전력, 장수명 등의 장점을 갖는 LED로 교체 중에 있다. 본 연구에서는 터널조명 LED 교체에 따른 효과 분석을 위하여 기존 터널조명이 저압나트륨램프인 8개소 터널에 대하여, LED 교체 전·후 터널 조도측정결과 및 1년간의 월별 전력사용량을 조사하였으며, 분석결과 터널조명 광원을 저압나트륨램프에서 LED로 교체 후 1년간 터널조명용 전력사용량은 26.1~59.6% 감소하였으며, 조도는 34.1~293% 향상된 것으로 나타났다.