• Title/Summary/Keyword: sodium lamp

Search Result 75, Processing Time 0.028 seconds

The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp (고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지)

  • Han, Tae-Hwan;Woo, Chun-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

Effect of Supplemental lighting on the Growth and Flowering of Rosa hybrida 'Nobles' in winter (겨울철 보광이 절화장미 'Nobles'의 생육 및 개화에 미치는 영향)

  • Na, Taek-Sang;Kim, Jeung-Gun;Choi, Kyong-Ju;Gi, Gwang-Yeon;Yoo, Yong-Kweon
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2007
  • This study was carry out to investigate the effect of supplemental lighting on the growth and flowering of Rosa hybrida 'Nobles' in winter. Supplemental lighting was treated during 5 hours at night with sodium lamp and fluorescent lamp, and cut flowers harvested 2 times for the experimental period. After supplemental lighting, air temperature and slab temperature in glasshouse was higher in sodium lamp treatment than control. Realtive humidity was low in sodium lamp treatment. Total nitrogen phosphate, potassium, calcium, and magnesium contents of stem in sodium lamp treatment were higher compare to the other treatment. In sodium lamp treatment, the potassium and magnesium content of leaf in control were lower than the others. Chlorophyll content was not different by source of lighting. Stem length and diameter was longer in sodium lamp treatment. In two times, the yield was highest in sodium lamp treatment. Therefore, supplemental lighting with sodium lamp in winter season was recommended for improving the yield and quality in cut rose 'Nobles'.

A Study on the Plant Cultivation by comparing Ultra Constant Discharge (UCD) Lamp lighting and Hi-Pressure Sodium Lamp lighting (초정압방전램프(UCD)와 나트륨램프를 적용한 식물재배에 관한 연구)

  • JEONG, P.G.;KIM, Y.C.;YANG, H.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • This study was conducted to research how UCD(Ultra Constant Discharge) lamp lighting affects plant cultivation. To get the results within a short time, lettuce seedling was selected as a plant and nutrient hydroponic beds were used in a dark room for 100% artificial lighting. Two beds were installed for same distance lighting condition with UCD lamp and Hi-pressure Sodium lamp each and another two beds were installed for same light intensity condition with each type of lamp. After 15 days of cultivation, for both conditions, the yields under UCD lamp were weighed more than that under Hi-pressure Sodium lamp. The result can be analyzed that the spectrum of UCD lamp having near sunlight characteristic is much superior to that of Hi-pressure Sodium lamp having a line spectrum characteristic on yellow and red wavelengths for plant cultivation.

Development of Electronic Ballast for 150W High Pressure Sodium Lamp (150W 고압나트륨램프용 전자식 안정기 개발)

  • 김순기;노재엽;이용후;최현배;이진우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.107-110
    • /
    • 2000
  • This paper deals with the design of the electronic ballast for high pressure sodium lamp, which consists of the ignitor and the resonant converter for driving the lamp. Also it contains PFC(Power Factor Controller) to improve such as power factor, low distortion etc. In this paper, we design the electronic ballast for the 150 watt high pressure sodium lamp.

  • PDF

The Algorithm of Life Time Diagnostics end Evaluating of Exchanges Time about High Pressure Sodium Vapor Lamp Using the LabVIEW Software Package (LabVIEW 소프트웨어 패키지를 이용한 고압나트륨전등의 교환시점 및 수명진단 알고리듬)

  • Han, Tae-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2004
  • It is necessary for starting voltage to him on high pressure discharge lamp. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in Electric discharge tube, So accelerative electron collide against vapour atom and second electron is generated, And rapidly the current flow to Electric discharge tube. This paper showed that the life cycle and exchanges time for all electric discharge lamp was different according to each manufactures, This paper is proposed the evaluating algorithm of exchanges time for high pressure sodium vapor lamp, used LabVIEW software package.

A PSpice Model for the Electrical Ballast of HID Lamps (전자식 안정기를 위한 HID Lamp 시뮬레이션 모델)

  • 지윤근;김남준
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.27-32
    • /
    • 2003
  • The thesis is used by PSpice circuit model to the characteristics of a fluorescent lamp modified form of he classical Cassie and Mayr equations in order to show the characteristics of HID(High-Intensity Discharge) Lamp. This is useful for applying high-frequency electric ballast for HID Lamp, and show that the result of experimentations and simulations, such as lamp rating, input voltage, high-frequency electric ballast which is using the ABM circuit model of the low pressure sodium lamp, come to the voltage and current wave.

Analysis of power usage and illuminance changes due to the replacement of tunnel lighting source from high pressure sodium lamp to LED (고압나트륨램프에서 LED램프로 터널조명등 교체에 따른 전력사용량 및 조도변화 분석)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.4
    • /
    • pp.211-220
    • /
    • 2021
  • Low-pressure sodium lamps, high-pressure sodium lamps, and fluorescent lamps are mainly used for tunnel lighting in Rep. of Korea, which accounts for the highest percentage in the tunnel maintenance costs. Therefore, tunnel lights are being replaced by LED lamp that have advantages with respect to low power consumption and sustainability. To analyze the effect of replacement high pressure sodium lamp with LED lamp, illumination and monthly power usage per year have been investigated for 10 tunnels. The usage of LED lamp results in illumination improvement from 27.9% to 490% and power saving around average 47.1%.

Electronic Ballast for HPS Lamps with Intrinsic Power Regulation over Lamp Life

  • Dehghani, Majid;Saghaiannejad, Seid Mortaza;Karshenas, Hamid Reza
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.526-534
    • /
    • 2009
  • This paper introduces the electronic ballast for high pressure sodium (HPS) lamps which provides power regulation during the whole lamp life without using a closed-loop power control system, in spite of large variations of lamp characteristics resulting from lamp aging. The structure of the electronic ballast and the parameters of HPS lamps are described. A mathematical model for the ballast is developed and used for the design and analysis of the ballast. A design procedure is presented to design the ballast which provides intrinsic power regulation over the whole lamp life. To improve the technical specifications of the ballast, the practical and standard constraints are considered in the design. According to the design procedure, an electronic ballast for 250-W HPS lamps is designed. All theoretical analyses are verified with the help of a semi-industrial experimental setup. The results validate that the designed ballast provides power regulation during the whole lamp life.

Effect of tunnel lighting replacement on power usage and illumination improvement: replacing low pressure sodium lamp with LED (터널 조명등 교체에 따른 전력사용량 및 조도 개선 효과: 저압나트륨램프 LED로 교체)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.185-196
    • /
    • 2020
  • Low-pressure sodium lamps, high-pressure sodium lamps and fluorescent lamps etc are mainly used tunnel lighting in Rep. of Korea. Power rates for tunnel lighting are known to account for the highest percentage in the tunnel maintenance costs. Therefore, tunnel lights are being replaced by LED that have advantages such as low power consumption and longevity. To analysis effect of replacement low pressure sodium lamp with LED, illumination and monthly power usage for a year are investigated for 8 tunnels. Power usage for tunnel lighting is decreased by 26.1% to 59.6%, and illumination is increased by 34.1% to 293% replacing low pressure sodium lamp with LED.