• 제목/요약/키워드: smoothing reactor

검색결과 14건 처리시간 0.021초

계통연계형 태양광발전 시스템의 불평형 보상기법 (The unbalance compensation methode of PWM converter in a Utility interactive Photovoltaic Generation System)

  • 이재훈;신철준;전기영;박춘우;전지용;이상집;오봉환;정춘병;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1008-1009
    • /
    • 2006
  • There is an application which uses smoothing reacter connecting each of the phases in order to make the system smaller comparison with an application using the insulating transformer in the utility interactive photovoltaic generation system using the PWM converter. In this case, there might be the occurence of the unbalance of output voltage, by the difference of smoothing reactor, connected on each of the lines. Therefore this study proposes that the method which maintains the balance and compensates the unblance which occured by the different volume of the smoothing reactor connected on each of the lines.

  • PDF

PWM 컨버터를 이용한 계통연계형 태양광발전 시스템 (A Utility Interactive Photovoltaic Generation System using PWM Converter)

  • 김대균;전기영;함연근;이승환;이승환;오봉환;이훈구;한경희
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.111-118
    • /
    • 2005
  • Since the residential load is an AC load and the output of solar cell is DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feed-forward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

SINGLE-PHASE CURRENT SOURCE INVERTER WITH PULSE AREA MODULATION SCHEME FOR SOLAR POWER CONDITIONER

  • Hirachi, K.;Matsumoto, K.;Ishitobi, M.;Ishibashi, M.;Nakaoka, M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.724-729
    • /
    • 1998
  • In general, a single-phase current-fed PWM inverter using IGBTs has some unique advantages for small scale distributed utility-interactive power supply system as compared with voltage-fed PWM inverter. In particular, this is more suitable and acceptable for a non-isolated type utility-interactive power conditioner, which is going to be widely used for residential solar photovoltaic (PV) power generation system in Japan. However, this current-fed PWM inverter has a significant disadvantage. The output current of this inverter includes large harmonic contents when the inductance of smoothing reactor in its DC side is not large enough to eliminate its current ripple components of this inverter. In order to overcome this problem, a new conceptual pulse area modulation scheme for this inverter is introduced in difference with conventional PWM strategy. This paper presents a new effective control implementation of this PV power conditioner which is able to reduce the harmonic component in the output current produced by the single-phase current-fed PWM inverter even when the ripple current in the smoothing DC reactor is relatively large. The operating principle of the proposed control strategy introdued for this inverter system is described, and its simulation results are evaluated and discussed herein.

  • PDF

HVDC 시스템의 고장 시 소음 및 진동 분석 (The Sound Noise and Vibration Analysis for HVDC System Faults)

  • 김찬기
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.21-28
    • /
    • 2006
  • 본 논문은 HVDC 시스템의 고장 시 고장 원인과 소음의 원인 및 기계적인 균열에 관하여 분석한 논문이다. 본 논문에는 전기설비의 소음과 진동의 원인을 분석하였고, 시스템의 고장을 정량적으로 분석하였다. 최종적으로 고장전류와 소음과 진동 방정식을 이용하여 Smoothing 리액터의 지지물의 균열의 원인이 분석되었다.

이동로봇의 원격제어를 위한 햅틱 글러브 개발 (Development of Haptic Glove for Remote Control)

  • 황요섭;이장명
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1030-1035
    • /
    • 2011
  • The remote control of mobile robot is widely used to perform dangerous and complex tasks such as underwater exploration and cleaning of nuclear reactor. For this purpose, the obstacle avoidance process will proceed to ensure a safe drive. In this paper, we tested that mobile robot drive in which replaced a pipe with a box. After we measured the distance around the obstacle through a sensor of robot, we got the information that changed haptic force from the distance of the obstacle.

DC - DC콘버어터의 소형화와 안정성 (A Miniturization and Stability of DC-to-DC Converters)

  • Kim, Hee-Jun
    • 대한전기학회논문지
    • /
    • 제37권8호
    • /
    • pp.528-533
    • /
    • 1988
  • The miniturization of a DC-to-DC converter in connection with the stability is investigated in this paper. As both the capacitance of the smoothing capacitor and the inductance of the reactor are reduced by rasing the switching frequency, it is known that the stability of the buck converter declines with the switching frequency but the buck-boost converter has a nearly uniform stability. Furthermore, that the buck-boost converter is suitable for the miniturization of circuit is cleared in the high frequency region above a certain switching frequency.

  • PDF

DC-DC 콘버어터의 고주파화와 안정성 (High Frequency Switching and Stability of DC-DC Converters)

  • 김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.824-827
    • /
    • 1987
  • The miniturization of a DC-DC converter circuit in connection with the stability is investigated in this paper. As both the capacitance of the smoothing capacitor and the inductance of the reactor are reduced by raising the switching frequency, it is known that the stability of the buck converter declines with the switching frequency but the buck-boost converter has a nearly uniform stability. Furthermore, that in the frequency region above a certain switching frequency the buck-boost converter is suitable for the miniturization of circuit is cleared.

  • PDF

계통연계형 태양광발전 시스템의 속응성 제어 (Rapid response control A Utility Interactive Photovoltaic Generation System)

  • 정춘병;전기영;이상현;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.279-285
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

PWM 컨버터를 이용한 계통연계 에너지시스템에 관한 연구 (A Study on Utility Interactive Energy System using PWM Converter)

  • 김길동;이한민;홍용기;김대균
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.288-291
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

HVDC 시스템의 고장 시 소음 및 진동 분석 (The Sound Noise and Vibration Analysis for HVDC System Faults)

  • 김찬기;박종광;최영도;임성주;문형배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2006
  • This paper deals with the HVDC system fault analysis and the sound noise analysis. In this paper, the reasons of the audible noise and vibration were analyzed, the fault waveform were analyzed using DTR (Digital Transient Recorder). Finally, using the fault current waveform and the vibration equation, the reason of crack of smoothing reactor support is estimated.

  • PDF