• 제목/요약/키워드: smooth water area

검색결과 46건 처리시간 0.029초

터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer -)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제5권2호
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF

도시 내 묵논습지 생물서식 특성 및 관리방안 -북한산국립공원 울대습지를 대상으로- (Habitat Characteristics and Management of Abandoned Rice Paddy Field Wetlands in Mountain - In Case of the Uldae Wetland in Bukhansan National Park -)

  • 유소연;허명진;한봉호;최진우
    • 한국환경복원기술학회지
    • /
    • 제21권4호
    • /
    • pp.11-23
    • /
    • 2018
  • The purpose of this study is to identify the ecological characteristics and biological interactions between species of the abandoned rice paddy field in mountainous areas and to suggest a management strategy for stable food chain formation and biodiversity enhancement. The study site is located in Uldae wetland of Songchu district Bukhansan National Park, site characteristics and biological habitat characteristics were identified through site survey and literature survey. With regard to physical environment, among geographical features, the Uldae Wetland and the neighborhood inside the basin was a gently sloping area($5{\sim}15^{\circ}$). And 64.0% of basin faced the north. With regard to water environment, the Uldae Wetland was wetland of rainfed paddy field depending on precipitation and the system of stream flowing into the wetland from valley. According to the results of examining flora in plant ecology, in general, they were herbaceous wetland species. 88.6% of existing plants inside the Uldae Wetland basin was a forest in the mountain. And Quercus spp. community and Pinus densiflora community accounted for 64.6% of that, and was dominant. Except for that, Salix koreensis community was distributed. The existing vegetation of Uldae Wetland inhabited wetland species and terrestrialization indicator species, and it was thought that partial terrestrialization inside the Uldae Wetland was in progress after the discontinuation of paddy cultivation, such as the expansion of Salix koreensis distribution area. In the status of appearing faunae in the Uldae Wetland with regard to wildbirds of appearing principal species, The Uldae wetland was based on a abandoned rice paddy field various wildlife, and was a wildlife feeding, spawning, and resting place. The water environment was an important factor in maintaining the wetland living creatures function, habitat of waterbirds and benthic macroinvertebrates, amphibians and odonate are spawning ground and habitat, it was affecting the vegetation ecosystem based on wetlands. In order to maintain the diversity of wildlife, it was important to maintain smooth water supply and water level. A stable food chain will be formed and the Uldae wetland biodiversity will be abundant by establishing the relationship between the species of Uldae wetland, which is abandoned rice paddy field, and the habitat environment favored by species belonging to the ecosystem stepwise linkage. The ecological characteristics of the Uldae wetlands and the relation between the species were analyzed and the environmental conditions were reflected in the planning and management plan of Uldae wetland ecology.

다양한 표면에서 유동 속도에 따른 풀 비등 열전달에 관한 연구 (Study of Pool Boiling Heat Transfer on Various Surfaces with Variation of Flow Velocity)

  • 강동규;이요한;서훈;정동수
    • 대한기계학회논문집B
    • /
    • 제37권4호
    • /
    • pp.343-352
    • /
    • 2013
  • 본 연구에서는 열전달 표면의 형상과 그 위에서의 유동 속도의 변화에 따른 풀 비등 열전달계수의 변화를 살펴보기 위해 평판, 낮은 핀, Thermoexcel-E, Turbo-B 표면을 사용하여 유동 속도를 변화시켜가며 임계 열유속까지 열전달계수를 측정하였다. 작동 유체로는 증류수를 사용하였고 사각 평면 히터($9.53{\times}9.53mm$)를 이용하여 네 가지 표면에서 임계 열유속까지의 데이터를 얻을 수 있도록 장치를 제작하였고 $60^{\circ}C$에서 유동 속도를 0, 0.1, 0.15, 0.2m/s로 변화시켜가며 데이터를 취했다. 실험 데이터를 보면 모든 표면에서 유동이 있을 때의 임계 열유속은 유동이 없을 때에 비해 높은 것으로 나타났다. 또한 표면적의 증가와 기포 이탈에 충분한 핀 간격 등으로 인해 낮은 핀 표면의 임계 열유속은 평판이나 Turbo-B, Thermoexcel-E 표면보다 훨씬 놓았고 평판에 비해서는 무려 5배 정도의 향상을 보였다. 한편 대형 냉동기의 증발기용으로 개발된 Turbo-B와 Thermoexcel-E 표면은 물에서 기포의 이탈 지름이 크므로 열전달계수와 임계 열유속 모두 예상보다 큰 효과를 나타내지 않았다. $50kW/m^2$이하의 저열유속에서는 모든 표면에 대해 유동 속도 증가에 따라 열전달계수가 증가하였다. 결론적으로 핵발전소의 증기발생기에 적용하기에는 낮은 핀 형상의 표면이 가장 좋은 것으로 나타났다.

우도(牛島) 분화구(噴火口)에서의 일윤회(一輪廻) 화산과정(火山過程) (One-cyclic Volcanic Processes at Udo Crater, Korea)

  • 황상구
    • 자원환경지질
    • /
    • 제26권1호
    • /
    • pp.55-65
    • /
    • 1993
  • Udo Island, some 3 km off the coast of Sungsan Peninsula at the eastern promontory of Cheju Island, occurs in such a regular pattern on the sequences which reprent an excellent example of an eruptive cycle. The island comprises a horseshoe-shaped tuff cone, a nested cinder cone on the crater floor, and a lava delta which extends over northwest from the moat between two cones. The volcanic sequences suggest volcanic processes that start with emergent Surtseyan eruption, progress through Strombolian eruption and end with lava effusion followed by reworking of smooth tephra on the tuff cone. Eruptive environment and hydrology of vent area in the Udo tuff cone are poorly constrained because the stratigraphic units under the tuff cone are unknown. It is thoughl, however, that the tuff cone could be mainly emergent because the present cone deposits show no evidence of marine reworking, and standing body of sea water could play a great role. The emergent volcano is characterized by distinctive steam-explosivity that results primarily from a bulk interaction between rapidly ascending magma and a highly mobile slurry. The sea water gets into the vent by flooding accross or through the top or breach of tephra cone. Udo tuff cone was constructed from Surtseyan eruption which went into with tephra finger jetting activities in the early stage, late interspersed with continuous uprush activities and proceeded to only continuous uprush activities in the last. When the enclosure of the vent by a long-lived tephra barrier would prevent the flooding and thus allow the vent to dry out, the Surtseyan eruption ceased to transmit into Strombolian activities, which constructed a cinder cone on the crater floor of the tuff cone. The Strombolian eruption ceased when magma in the conduit gradually became depleted in gas. In the case of Udo, the last magmatic activity was Hawaiian-type (and/or fountain) which accumulated basalt lava delta. And then the loose tephra of the tuff cone reworked over the moat lava and the northeastern flank.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Occurrence of Rhizopus Soft Rot on Peach (Prunus persica var. vulgaris) Caused by Rhizopus nigricans in Korea

  • Kwon, Jin-Hyeuk;Kang, Soo-Woong;Park, Chang-Seuk
    • Mycobiology
    • /
    • 제28권4호
    • /
    • pp.177-179
    • /
    • 2000
  • A soft rot of fruits caused by Rhizopus nigricans occurred on peach (Prunus persica var. vulgaris) in The Chinju City Agricultural Products Wholesale Marke during in summer season of 2000. The disease infection usually started from wounding after harvest fruits, and then moved to outside. At first, the lesions started with water soaked and rapidly softened and diseased area gradually expanded. In severely infected film house, the rate of infected fruits reached 65.2%. Numerous sporangiospores were produced on the diseased fruits. Most of the sporangiospores were appeared to be readily dispersed in the air. The mycelia grew surface of fruits and produced stolons. Colonies on potato dextrose agar at $25{\sim}30^{\circ}C$ white cottony at first becoming heavily speckled by the presence of sporangia and the browinish black at maturity, spreading rapidly by means of stolons fired at various points to the substrate by rhizoids. Sporangia were $85.3{\sim}243.5{\times}53.4{\sim}219.2\;{\mu}m$ in size and were globose or sub-globose with. somewhat flattened base. The color of sporangia was white at first and then turned black with many spores, and never over-hanging. Sporangiophores were $8.9{\sim}36.6\;{\mu}m$ in width, smooth-walled, non-septate, light brown, simple, long, arising in groups of $3{\sim}5$ from stolons opposite rhizoids. Sporangiospores was $9.7{\sim}24.8{\times}5.9{\sim}15.8\;{\mu}m$, irregular, round, oval, elongate, angular, and browinish-black streaked. Columella was $70.2{\times}149.7{\mu}m$. brownish gray, and umberella-shaped when dehisced. The causal organism was identified as. Rhizopus nigricans Lind on the basis of the morphiogical characteristics of the fungus. Rhizopus soft rot on peach (Prunus persica) caused by the fungi has not been reported in Korea. This is the first report of rhizopus soft rot on peach caused by Rhizopus nigricans in Korea.

  • PDF

Occurrence of Rhizopus Soft Rot on Squash (Cucurbita moschata) Caused by Rhizopus stolonifer in Korea

  • Kwon, Jin-Hyeuk;Kang, Soo-Woong;Park, Chang-Seuk
    • The Plant Pathology Journal
    • /
    • 제16권6호
    • /
    • pp.321-324
    • /
    • 2000
  • season of 2000. The disease infection usually started from flower, peduncle and young fruits, then moved to flower stalk, stem and leaves. At first, the lesions started with water-soaked, rapidly softened, and then the area gradually expanded. In severely affected film house, the rate of infected fruits reached to 28.6%. Numerous sporangiospores were formed on the diseased fruits, flower stalk, stem and leaves. Most of the sporangiospores were appeare to be rapidly dispersed in the air. The mycelia grew on the surface of host and formed stolons. Colonies on potato dextrose agar were cottony at first brownish black at maturity. Sporangia were 125.3${\times}$294.2 ${\mu}$m. globose or sub-globose with somewhat flattened base. White at first the black, many spored, and are never overhanging. Sporangiophores were 2.7-6.8${\times}$12.9-33.9 ${\mu}$m, smooth-walled, non-septate, light brown, simple, long, arising in groups of 3-5 from stolons opposite rhizoids. Sporangiophores were 8.6-21.1${\times}$6.41-1.7 ${\mu}$m, irregular, round, oval, elongate, angular and brownish-black streaked. Columella were 63.8${\times}$140.4 ${\mu}$m. brownish gray, umberella-shaped when dehisced. The causal organism was identified as Rhizopus stolonifer Lind on the basis of the morphological characteristics of the fungus. Rhizopus soft rot on squash (Cucurbita moschata) caused by the fungi has not been previously reported in Korea.

  • PDF

카복실레이트계 시멘트의 접착력에 관한 비교 연구 (COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS)

  • 이한무
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

저토피 철도터널구간의 안전 및 시공성을 고려한 개선된 강관다단 그라우팅 공법 적용성 분석 (Applicability Analysis of an Improved Multistep Steel Pipe Grouting Method in Shallow Depth Railway Tunnels in Considering Safety and Constructability)

  • 김낙석;최기성;김석현
    • 대한토목학회논문집
    • /
    • 제40권1호
    • /
    • pp.97-103
    • /
    • 2020
  • 저토피 철도터널구간의 안전 및 시공성을 고려한 굴착보조공법으로서 강관다단 그라우팅 기술이 선정되었다. 특히, 공사 중 과도한 주입압에 의한 지반파괴로 피해가 발생할 우려가 있어 기존 강관다단 그라우팅 공법을 새롭게 개선하여 적용하였다. 본 연구는 00공단에서 발주한 000노반시설 기타공사 구간 중 00안 고속도로 및 00휴게소(하행) 진입로 하부로 통과하는 토피고 11.3~12.1 m 두께의 저토피 철도터널 현장에서 수행하였다. 개선된 강관다단 그라우팅 공법은 새로운 한계주수시험법을 이용한 시공 전 시공조건 평가 기술, 절리의 간격평가, 적합한 주입압력 평가, 최적의 작업완료시간 평가, 주입유형분석에 의한 주입효과평가 기술 등이다. 개선된 강관다단 그라우팅 공법의 적용으로 터널굴착공사 중상부 저토피 구간의 도로를 원활하게 운영할 수 있는 근거를 마련할 수 있었다. 또한, 향후 저토피 구간의 터널강관다단 그라우팅 공사뿐만 아니라 다양한 터널(도로, 지하철, 공동구 등) 강관다단 그라우팅 공사에 적용될 수 있는 가능성을 확인하였다.

Electrical Characteristic of IGZO Oxide TFTs with 3 Layer Gate Insulator

  • Lim, Sang Chul;Koo, Jae Bon;Park, Chan Woo;Jung, Soon-Won;Na, Bock Soon;Lee, Sang Seok;Cho, Kyoung Ik;Chu, Hye Yong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.344-344
    • /
    • 2014
  • Transparent amorphous oxide semiconductors such as a In-Ga-Zn-O (a-IGZO) have advantages for large area electronic devices; e.g., uniform deposition at a large area, optical transparency, a smooth surface, and large electron mobility >10 cm2/Vs, which is more than an order of magnitude larger than that of hydrogen amorphous silicon (a-Si;H).1) Thin film transistors (TFTs) that employ amorphous oxide semiconductors such as ZnO, In-Ga-Zn-O, or Hf-In-Zn-O (HIZO) are currently subject of intensive study owing to their high potential for application in flat panel displays. The device fabrication process involves a series of thin film deposition and photolithographic patterning steps. In order to minimize contamination, the substrates usually undergo a cleaning procedure using deionized water, before and after the growth of thin films by sputtering methods. The devices structure were fabricated top-contact gate TFTs using the a-IGZO films on the plastic substrates. The channel width and length were 80 and 20 um, respectively. The source and drain electrode regions were defined by photolithography and wet etching process. The electrodes consisting of Ti(15 nm)/Al(120 nm)/Ti(15nm) trilayers were deposited by direct current sputtering. The 30 nm thickness active IGZO layer deposited by rf magnetron sputtering at room temperature. The deposition condition is as follows: a rf power 200 W, a pressure of 5 mtorr, 10% of oxygen [O2/(O2+Ar)=0.1], and room temperature. A 9-nm-thick Al2O3 layer was formed as a first, third gate insulator by ALD deposition. A 290-nm-thick SS6908 organic dielectrics formed as second gate insulator by spin-coating. The schematic structure of the IGZO TFT is top gate contact geometry device structure for typical TFTs fabricated in this study. Drain current (IDS) versus drain-source voltage (VDS) output characteristics curve of a IGZO TFTs fabricated using the 3-layer gate insulator on a plastic substrate and log(IDS)-gate voltage (VG) characteristics for typical IGZO TFTs. The TFTs device has a channel width (W) of $80{\mu}m$ and a channel length (L) of $20{\mu}m$. The IDS-VDS curves showed well-defined transistor characteristics with saturation effects at VG>-10 V and VDS>-20 V for the inkjet printing IGZO device. The carrier charge mobility was determined to be 15.18 cm^2 V-1s-1 with FET threshold voltage of -3 V and on/off current ratio 10^9.

  • PDF