• 제목/요약/키워드: smoke flow

검색결과 344건 처리시간 0.021초

일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험 (The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster)

  • 유영일;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF

Smoldering 연소로 인한 화재사고 조사보고 소개 및 이론적 해석 (Investigation and Theoretical Analysis of a Fire Accident Caused by Smoldering Combustion)

  • 김연승;변영철;황정호
    • 한국화재소방학회논문지
    • /
    • 제13권3호
    • /
    • pp.3-17
    • /
    • 1999
  • 산호제의 양이 충분치 못한 밀폐된 공간에서는 화재가 발생하지 않으리라는 기대를 깨고, 다공성 물질내부에서 공극안에 있는 산화제를 이용하여 서서히 연소되는 smoldering 반응을 통하여 대형 화재가 발생할 수 있다. 본 논문에서는 하나의 실제 화재 사건을 화재 조사 방법에 의하여 기술한 보고서를 바탕으로 하여 smoldering 연소가 화재의 발생에 미치는 영향을 예시하였으며, 예시된 사고의 smoldering 연소를 강제대류에 의한 하향식 역방향 smoldering으로 모델링하였다. 화학반응으로는 열분해가 없는 1 단계 반응이 채택되어, 온도 및 산화제의 공간적 분포와 smoldering의 전파속도를 수치적으로 모사하였다. 수치결과로서 유입되는 산화제의 양과 연료의 공극률이 반응지역의 전파속도를 결정하는 가장 우세한 인자로 파악되었다. 그러므로 smoldering 에 의한 화재 발생시 유입되는 산화제의 양과 연료의 공극률과의 관계를 알고 있다면 주어진 연료의 공극률에 대하여 유입되는 산화제의 양을 제어함으로써 불길로의 천이를 억제할 수 있음을 제시하고 있다.

  • PDF

화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰 (Analysis for Fire Spread through Double Skin Facade System with FDS)

  • 허윤택;박창복;성준식;윤명오
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-116
    • /
    • 2009
  • 본 연구는 Double Skin System의 화재 전파 위험성을 전산유체역학모델인 FDS를 이용하여 평가하였다. 화재모델링을 구현하기 위해 오피스 용도의 단위 구획공간을 화재지역으로 선정하였으며, 화재시나리오는 외창으로의 연소확대 위험 분석을 위하여 일반적으로 많이 설치되는 시스템조건들을 Case로 선정하여 분석하였다. 본 연구의 목적은 일반적으로 많이 사용되는 Double Skin System의 설치 간격에 따른 건물상층부로의 화재확대 위험성을 평가하고, 이에 따른 방화대책 등을 수립하는데 있다. 해석 결과, 더블스킨 중간층 간격이 넓을수록 상부층으로 연소확대 영향이 작은 것을 확인할 수 있었으며, 중간층 간격이 1m 미만인 경우는 발화층 상부 2개층으로 연소확대가 예상되므로 층간연소 확대 방지 시스템이 요구됨을 알 수 있다.

RTLS 시스템을 활용한 화재시 행동분석 연구 (The Research of the Analysis of Movement from a Fire using RTLS System)

  • 임경범;김하영;이동호
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.98-103
    • /
    • 2010
  • 건물 안에 있는 사람의 보호는 재해방지 설계 시 우선적인 고려사항이다. 그러나 실제 상황에서 연기에 대한 가시도, 상호간의 거리, 사고방식 및 교통정체에 대한 인지정도 등을 계획하는 것은 어렵다. 본 연구의 목적은 변수에 대한 패턴 변화의 모듈화를 분석해 피난 시뮬레이션의 기초 자료를 활용하기 위함으로 이를 위해 태그로 부터 전파를 감지하고 실시간으로 위치를 파악하는데 RTLS(실시간 위치 시스템) 시스템을 활용하였다. RTLS 시스템을 활용하여 피난 패턴에 대해 도수안경을 착용하여 가시도에 따른 이동속도, 건축 시 문의 최적 크기를 추정하기 위한 문의 크기에 따른 흐름 분석 및 병목상황 시 사람들의 움직임에 대한 3가지 패턴에 대해 분석하고 가시화 하였다. 이 결과 실제 사람들의 피난 시 다양한 상황에서 수치해석 적용에 기대할 것으로 판단된다.

바이오디젤용 산화방지제인 아민안정제들의 효과 (Effect of Amine-Based Antioxidants as Stabilizers for Biodiesel)

  • 박수열;김헌수;김승회
    • Tribology and Lubricants
    • /
    • 제31권6호
    • /
    • pp.258-263
    • /
    • 2015
  • Biodiesel is an environmentally-friendly fuel with low smoke emission because it contains about 10% oxygen. Biodiesel fuel prepared by transesterification of vegetable oil or animal fats is susceptible to auto-oxidation. The rate of auto-oxidation depends on the number of methylene double bonds contained within the fatty acid methyl or ethyl ester groups. Biodiesel may be easily oxidized under several conditions, i.e., upon exposure to sunlight, temperature, oxygen environment. Maintenance of the fuel quality of biodiesel requires the development of technologies to increase the resistance of biodiesel to oxidation. Treatment with antioxidants is a promising approach for extending the shelf-life or storage time of biodiesel. The chemical properties of various amine-based antioxidants were evaluated after synthesis of the antioxidants by condensation of phenylenediamine with alkylamines at room temperature. In general, the oxidative stability can be assessed based on various experimental parameters. Such parameters may include temperature, pressure, and the flow rate of air through the samples. The Rancimat method (EN14112) was selected because it is a rapid technique that requires very little sample and provides good precision for oxidative degradation analysis. Specifically, the EN 14112 technique provides enhanced efficiency for oxidative stability evaluation when a larger ester head group is utilized. Therefore, this technique was employed for evaluation of the oxidation stability of biodiesel by the Rancimat method (EN14112).

고체로켓모터의 적외선 신호에 관한 수치적·실험적 연구 (Numerical and Experimental Study on Infrared Signature of Solid Rocket Motor)

  • 김상민;김민택;송순호;백국현;윤웅섭
    • 한국추진공학회지
    • /
    • 제18권5호
    • /
    • pp.62-69
    • /
    • 2014
  • 미사일의 탐지, 인식 및 추적 및 적외선을 줄여 피탐지성을 최소화 하는 데에 있어 로켓 플룸의 적외선 신호는 중요한 역할을 한다. 저연 추진제 및 무연 추진제를 사용하는 소형 고체로켓모터를 사용하여 로켓 플룸의 적외선 신호를 계측하였다. 로켓 플룸의 적외선 신호를 예측하기 위해 플룸의 유동장에 대한 전산모사를 수행하였으며, layered integration 방법을 사용하여 적외선 신호를 예측하였다. 해석 및 계측 결과는 잘 일치하였다. 두 신호 모두 $H_2O$에 의해 $2.5-3.0{\mu}m$영역에서, CO 및 $CO_2$에 의한 $4.5{\mu}m$ 영역에서 강한 신호를 나타낸다. 계측 결과, $4.3{\mu}m$ 영역에서 해석 결과와 다르게 강한 신호가 나타나는데, 이는 대기 중의 $CO_2$에 의한 흡수를 보정하는 과정에서 발생하는 실험 오차로 판단된다.

Evaluation of Evacuation Safety in University Libraries Based on Pathfinder

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.237-246
    • /
    • 2024
  • In recent years, the frequent occurrence of fire accidents in university libraries has posed significant threats to the safety of students' lives and property, alongside negative social impacts. Accurately analyzing the factors affecting evacuation during library fires and proposing optimized measures for safe evacuation is thus crucial. This paper utilizes a specific university library as a case study, simulating fire evacuation scenarios using the Pathfinder software, to assess and validate evacuation strategies and propose relevant optimizations. Pathfinder, developed by Thunderhead Engineering in the United States, is an intuitive and straightforward personnel emergency evacuation assessment system, offering advanced visualization interfaces and 3D animation effects. This study aims to construct evacuation models and perform simulation analysis for the selected university library using Pathfinder. The library's structural layout, people flow characteristics, and the nature of fire and smoke spread are considered in the analysis. Additionally, evacuation scenarios involving different fire outbreak locations and the status of emergency exits are examined. The findings underscore the importance of effective evacuation in fire situations, highlighting how environmental conditions, individual characteristics, and behavioral patterns significantly influence evacuation efficiency. Through these investigations, the study enhances understanding and optimization of evacuation strategies in fire scenarios, thereby improving safety and efficiency. The research not only provides concrete and practical guidelines for building design, management, and emergency response planning in libraries but also offers valuable insights for the design and management of effective evacuation systems in buildings, crucial for ensuring occupant safety and minimizing loss of life in potential hazard situations

진동하는 NACA 0012 에어포일의 근접후류 측정 (Near-wake Measurements of an Oscillating NACA 0012 Airfoil)

  • 김동하;김학봉;장조원
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.1-8
    • /
    • 2006
  • 진동하는 에어포일의 후류에 미치는 레이놀즈수의 영향을 조사하기 위한 실험적 연구를 수행하였다. NACA 0012 에어포일은 1/4 시위를 기준으로 피칭운동을 하고, $\pm$6$^{\circ}$ 내에서 진동하도록 설정하였다. 진동하는 에어포일에서 후류를 측정하기 위하여 2축 열선풍속계가 사용되었고 연선 가시화 기법이 경계층을 관찰하기 위하여 사용되었다. 실험조건에서 자유흐름속도는 1.98, 2.83 그리고 4.03 m/s이며, 이를 근거로 한 레이놀즈수는 각각 $2.3{\times}10^4$, 3.3${\times}10^4$, 4.8${\times}10^4$이다. 모든 경우에 에어포일 진동수는 무차원 진동수 K=0.1에 맞게 조절되었다. 실험 결과, 피칭하는 에어포일의 경계층 및 후류 유동 특성은 레이놀즈수 2.3$\times$104, 3.3$\times$104 사이에서 크게 다르게 나타나며, 레이놀즈수 3.3${\times}10^4$와 4.8${\times}10^4$에서 유사하게 나타난다. 이것은 레이놀즈수 2.3$\times$104에서 비정상 분리가 크게 지연되기 때문이다.

주야간 겸용 표면영상유속계 개발을 위한 원적외선 카메라의 적용성 검토 (A Test of a Far Infrared Camera for Development of New Surface Image Velocimeter for Day and Night Measurement)

  • 류권규;김서준;유병남;배인혁
    • 한국수자원학회논문집
    • /
    • 제48권8호
    • /
    • pp.659-672
    • /
    • 2015
  • 홍수시 하천의 유속 측정을 위한 표면영상유속계에서 가장 기본이 되는 단계는 적절한 영상을 취득하는 것이다. 하지만 영상 획득에 있어 야간에 발생하는 홍수 흐름을 촬영하는 것은 매우 어렵다. 이에 본 연구에서는 표면영상 유속계의 야간 영상 획득 장치로 원적외선 카메라를 이용하는 방안을 검토하였다. 원적외선 카메라는 별도의 조명을 필요로 하지 않으므로, 주야간 모두 영상을 획득할 수 있는 장점이 있다. 또한 안개나 연기의 영향을 받지 않아서 고정식 표면영상유속계를 구성하는 좋은 대안이 될 수 있다. 원적외선 영상을 이용한 유속 산정의 결과를 비교하기 위해, 보통의 가시광 카메라와 근적외선 카메라를 이용한 동시 촬영을 하여 영상을 분석하였다. 아울러 소형 프로펠러 유속계에 의한 유속 측정 자료와 비교하였다. 정확도 분석 결과 원적외선의 주간 영상을 이용할 경우 최소-9%에서 최대 -19%의 오차를 나타냈고, 야간 영상을 이용할 경우 최소 -10%에서 최대 -23%의 오차를 나타냈다. 또한 일반캠코더를 이용한 경우와 비교하여 최대 10% 이내의 차이를 보였기 때문에 주야간 유속 측정에 원적외선 카메라의 적용이 가능한 것을 확인하였다. 다만 주간 영상에 비해 야간 영상이 약간 흐려지는 경향이 있기 때문에, 이러한 영상을 적절히 분석하기 위한 지속적인 연구가 필요할 것으로 생각한다.

설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008)

  • 한화택;최창호;이대영;김서영;권용일;최종민
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.