• Title/Summary/Keyword: small-scale water supply system

Search Result 40, Processing Time 0.024 seconds

An experimental study on decision making for multi-source water (다중수원 수처리 의사결정에 관한 실험적 연구)

  • Jung, Jungwoo;Cho, Hyeong-Rak;Lee, Sangho;Chae, Soo-Kwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • A combined treatment system using multiple source water is becoming important as an alternative to conventional water supply for small-scale water systems. In this research, combined water treatment systems were investigated for simultaneous use of multi-source water including rainwater, ground water, river water, and reclaimed wastewater. A laboratory-scale system was developed to systematically compare various combinations of water treatment processes, including sand filtration, microfiltration (MF), granular activated carbon (GAC), and nanofiltration (NF). Results showed that the efficiency of combined water treatment systems was affected by the quality of feed waters. In addition, a simply approach based on the concept of linear combination was suggested to support a decision-making for the optimum water treatment systems with the consideration of final water quality.

A small-scale membrane electro-dialyser for domestic use

  • Chaalal, Omar;Hossain, Md.M.
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.43-52
    • /
    • 2015
  • A small-scale electro-dialysis system was constructed for domestic use. It is composed of six compartments in which five special polystyrene ionic membranes are housed. A series of experiments on the transport of sodium and chloride ions through polystyrene membranes was performed and the effects of electric current and voltage on the pH of water were investigated. This electrodialyser could reduce the NaCl content to an acceptable level (5307 mg/L) when water containing 9945 mg/L of sodium chloride is fed to the electrodialyser. The reduction was by the action of direct current 60 mA/100 mA when a 15 V / 20 V potential is maintained across the membrane. The results showed that the pH of the treated water attained a value in the range of 7-8, with the chloride concentration of 5307 mg/L when the voltage was in the range of 20 volts. This was achieved when two of the small-scale electro-dialysers were placed in series and the solutions from the respective compartments were mixed. This is considered useful because this complies to the requirement of drinking water standard both in terms of chloride and pH. Therefore, this type electrodialyserhas the potential for domestic uses in isolated houses where potable water supply is not available.

A Strategy for Improving the Sewerage Systems of Two Rural Areas in Gyeonggi Province (경기도의 2개 시.군 사례를 통한 농어촌지역 하수도 정비 추진 방안)

  • Moon, Chul-Hwan;Ahn, Ji-Hoon;Jang, Mi-Jeong;Lee, Sang-Hyup;Cho, Young-Moo;Kim, Yun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.563-580
    • /
    • 2010
  • In 2009 the Korea Ministry of Environment announced 'A Comprehensive Plan for the Improvement of Sewer Service in Rural Area' aiming at reduction of the sewer service gap between urban and rural areas as well as improvement in the residential environment of the rural area. According to the plan, the sewer system supply rate for the rural area is expected to reach up to 75% until 2015 with the budget of 4.7 trillion won (Korean currency). It is not certain, however, that the increase in the sewer system supply rate will accompany improvement of water quality in receiving water because several veiled problems that can occur in small-scale sewer treatment plants are poorly addressed in the plan. In this study, those issues for the small-scale sewer treatment plants and their solutions were discussed based on a case study in which we investigated 19 treatment facilities at two rural regions in Gyeonggi province. This study also included strategies useful for the plan. From the results of investigation, some problems, e.g., high hourly variations but low in flowrates and low mass loading were commonly identified. Although operation parameters in sewer treatment plants require to be modified depending on the mass loading, most of the plants were operated with the initial design parameters which causes the decrease of removal efficiency. In the intensive diagnosis, we arranged and applied solutions (e.g., flow equalization, air on/off time control, etc) to the two selected plants and found out improvement of effluent water quality, especially organic matters (COD and SS) and T-N with better denitrification performance.

Development of Water Demand Forecasting Simulator and Performance Evaluation (단기 물 수요예측 시뮬레이터 개발과 예측 알고리즘 성능평가)

  • Shin, Gang-Wook;Kim, Ju-Hwan;Yang, Jae-Rheen;Hong, Sung-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.581-589
    • /
    • 2011
  • Generally, treated water or raw water is transported into storage reservoirs which are receiving facilities of local governments from multi-regional water supply systems. A water supply control and operation center is operated not only to manage the water facilities more economically and efficiently but also to mitigate the shortage of water resources due to the increase in water consumption. To achieve the goal, important information such as the flow-rate in the systems, water levels of storage reservoirs or tanks, and pump-operation schedule should be considered based on the resonable water demand forecasting. However, it is difficult to acquire the pattern of water demand used in local government, since the operating information is not shared between multi-regional and local water systems. The pattern of water demand is irregular and unpredictable. Also, additional changes such as an abrupt accident and frequent changes of electric power rates could occur. Consequently, it is not easy to forecast accurate water demands. Therefore, it is necessary to introduce a short-term water demands forecasting and to develop an application of the forecasting models. In this study, the forecasting simulator for water demand is developed based on mathematical and neural network methods as linear and non-linear models to implement the optimal water demands forecasting. It is shown that MLP(Multi-Layered Perceptron) and ANFIS(Adaptive Neuro-Fuzzy Inference System) can be applied to obtain better forecasting results in multi-regional water supply systems with a large scale and local water supply systems with small or medium scale than conventional methods, respectively.

Characteristics of Radon Reduction of Small-scale Water Supply System (소규모수도시설 지하수의 라돈저감 특성)

  • Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.37-50
    • /
    • 2019
  • It is possible that radon removal in groundwater of small-scale water supply system (SWSS) is caused by atmospheric storage and aeration facilities installed in the water tank. Radon removal rates at water tank and tap of the 32 SWSS during summer season ranged from -69.3% to 62.7% (average 25.7%) and from -64.3% to 83.1% (average 30.3%) while those of 16 SWSS during autumn season ranged from 21.3% to 78.0% (average 42.8%) and from 17.7% to 66.9% (average 44.8%). The reason of higher radon removal rate in the autumn season compared with the summer season is due to higher atmospheric storage effect by lower groundwater use rate. The radon removal rates at the water tank from 12 SWSS were 47.4~94.0% (average 78.9%), in which the removal rates at the atmospheric storage are also included. Atmospheric storage and aeration can be used to reduce radon concentration in SWSS groundwater. For more efficient use of radon reduction, further studies are necessary to assess the radon removal rate considering variation conditions of radon concentration in groundwater, size and forms of water tank, change in groundwater usage rate, aeration capacity and ventilation facilities.

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

Occurrence of Arsenic, Strontium, and Selenium in Drinking Water in Kyungpook Province, Korea, in Relation to Geologic Formations (경북지역의 먹는 물에서 지질에 따른 비소, 스트론튬, 셀레늄 검출 특성)

  • Lee, Heageun;Cha, Sangdeok;Choi, Jeonhak;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.1
    • /
    • pp.55-60
    • /
    • 2015
  • As the water supply system has been installed over the country, the management of drinking water could be easier and controlled by experts. This helps to supply safe water to public. However, in rural area, small scale water treatment systems or groundwater haves been used as drinking water supplier. The drinking water including groundwater contains various contaminants. Private or small scale water treatment system can be contaminated with heavy metals such as arsenic, selenium and strontium which are usually originated from natural source. Arsenic, selenium and strontium have been determined from the goundwater, small scale water treatment system in the Kyungpook area. The results have been compared with the Korean and international standards. The results were analyzed on the geological characteristics of the area. Among the total of 1,412 samples, 76 samples showed higher concentration of arsenic than WHO guideline and the Korean drinking water standard. Total 4 samples had higher contents of selenium than WHO guideline which was $10{\mu}g/L$. In the analysis of geological characteristics, arsenic was highly released from a few area and which are in order of biotite granodiorite > biotite granite > daegu formation. Selenium has been highly released from biotite granite > black shale > diluvium.

Analysis on the Settlement Conditions in the Troubled Reclaimed Areas Under State Control (III) - Living Conditions in Rural communities - (未完工干拓地의 定住生活 實態分析 (III) - 部落의 生活環境 -)

  • Choi, Soo-Myung;Hwang, Han-Cheol
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.3
    • /
    • pp.73-80
    • /
    • 1991
  • In Korea, small-scale reclaimed areas have been suffering from many problems because of the lack of comprehensive developing strategy although considerable investments have been inputed by the public sector since 1970's. For 3 reclaimed sites in Chonnam Province chosen as case study areas, the analysis, the third attempt of widely-spanned studies on areal conditions, concentrated on their living conditions. Its results were as follows : 1. Although rural residents have increased their concern on health and medical services, the public sector can only serve basic and emergent level of them, and therefore, the private sector, which is mostly placed in urban areas and costed much higher than public one, has the dominant share of those services. So, because those costs are a great expense to rural residents, their supplying system should be planned with special reference to lightening the economic burden of them. 2. By the development of locally fitted programs and innovative systems, the rural education should be qualitatively improved to deal successfully with its small scale. That will result in increasing the schooling rate to schools in rural communities, lightening the economic burden of rural residents on education services and finally activating them to contribute the betterment of rural education. 3. Servicing level of water supply, sewerage and garbage disposal in the reclaimed areas has been remaining at the lower order even in other rural areas. In the design of rural water supply, average daily consumption per capita should be changed according to the composition rate of fishing households and variety of the source of water supply. 4. Most of rural residents in the reclaimed areas want to establish the welfare facilites for the infant, youth, aged and public bath However in the long-term basis, the cooperative production and processing facilities should be considered for modernized efficient farming.

  • PDF

A Study on Space Creation and Management Plan according to Characteristics by Type in Each Small-Scale Biotope in Seoul - Base on the Amphibian Habitats - (서울시 소규모 생물서식공간 유형별 특성에 따른 조성 및 관리방안 연구 - 양서류 서식지를 중심으로 -)

  • Park, Ha-Ju;Han, Bong-Ho;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.2
    • /
    • pp.110-126
    • /
    • 2024
  • This study conducted a classification of small-scale biological habitats created in Seoul to analyze and synthesize location characteristics, habitat structure, biological habitat functions, and threat factors of representative sites, as well as derive creation and management problems according to the ecological characteristics. The aim was to suggest improvement measures and management items. Data collected through a field survey was used to categorize 39 locations, and 8 representative sites were selected by dividing them into location, water system, and size as classification criteria for typification. Due to the characteristics of each type, the site was created in an area where amphibian movement was disadvantageous due to low or disconnected connectivity with the hinterland forest, and the water supply was unstable in securing a constant flow and maintaining a constant water depth. The habitat structure has a small area, an artificial habitat structure that is unfavorable for amphibians, having the possibility of sediment inflow, and damage to the revetment area. The biological habitat function is a lack of wetland plants and the distribution of naturalized grasses, and threats include the establishment of hiking trails and decks in the surrounding area. Artificial disturbances occur adjacent to facilities. When creating habitats according to the characteristics of each type, it was necessary to review the possibility of an artificial water supply and introduce a water system with a continuous flow in order to connect the hinterland forest for amphibian movement and locate it in a place where water supply is possible. The habitat structure should be as large as possible, or several small-scale habitats should be connected to create a natural waterfront structure. In addition, additional wetland plants should be introduced to provide shelter for amphibians, and facilities such as walking paths should be installed in areas other than migration routes to prevent artificial disturbances. After construction, the management plan is to maintain various water depths for amphibians to inhabit and spawn, stabilize slopes due to sediment inflow, repair damage to revetments, and remove organic matter deposits to secure natural grasses and open water. Artificial management should be minimized. This study proposed improvement measures to improve the function of biological habitats through the analysis of problems with previously applied techniques, and based on this, in the future, small-scale biological habitat spaces suitable for the urban environment can be created for local governments that want to create small-scale biological habitat spaces, including Seoul City. It is significant in that it can provide management plans.

Development of a Wave Absorbing System Using a Liquefied Sandbed

  • Kang, Yoon-Koo;Takahashi, Shigeo
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.4 s.71
    • /
    • pp.9-16
    • /
    • 2006
  • A new wave-absorbing system, called the liquefied sandbed wave barrier (LSWB) system, is currently under development at the Port and Airport Research Institute (PARI) of Japan. The wave damping effect by the LSWB system is substantial, as confirmed by small-scale experiments and FEM numerical calculations, i.e., the wave transmission coefficient of the system is less than 0.2. Here, the results of large-scale experiments arediscussed in view of practical application. Although the LSWB system provides high wave damping, nearly equal to theoretical values, difficulty exists in obtaining a homogeneously liquefied sandbed, due to the occurrence of liquefied sandbed compaction by cyclic wave loading, which in turn, reduces excess pare pressure and the wave damping effect. These two phenomena primarily occur when the sandbed is composed of fine sand with small permeability. Based on experimental results, we propose a design method that includes countermeasures against such problems, and a prototype LSWB system is constructed in a very large wave flume at PARI. Wave damping by the prototype LSWB system is confirmed to be quite stable and high, as predicted by theoretical calculations.