• 제목/요약/키워드: small wind power

검색결과 330건 처리시간 0.023초

Improved LVRT Capability and Power Smoothening of DFIG Wind Turbine Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.568-575
    • /
    • 2011
  • This paper proposes an application of energy storage devices (ESD) for low-voltage ride-through (LVRT) capability enhancement and power smoothening of doubly-fed induction generator (DFIG) wind turbine systems. A grid-side converter (GSC) is used to maintain the DC-link voltage. Meanwhile, a machine-side converter (MSC) is used to control the active and reactive powers independently. For grid disturbances, the generator output power can be reduced by increasing the generator speed, resulting in an increased inertial energy of the rotational body. Design and control techniques for the energy storage devices are introduced, which consist of current and power control loops. Also, the output power fluctuation of the generator due to wind speed variations can be smoothened by controlling the ESD. The validity of the proposed method has been verified by PSCAD/EMTDC simulation results for a 2 MW DFIG wind turbine system and by experimental results for a small-scale wind turbine simulator.

풍력발전을 위한 소용량 영구자석형 동기발전기의 설계 및 해석 (Design and Analysis of Direct-Coupled, Small-Scaled Permanent Magnet Generator for Wind Power Application)

  • 김일중;최장영
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.39-51
    • /
    • 2014
  • This paper deals with design of a direct-coupled, small-scaled permanent magnet generator (PMG) for wind power application. First, this paper determines rated power and speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit including slot opening, teeth width and yoke thickness is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot considering winding packing factor. Finally, finite element (FE) method is employed in analyzing the details of the designed PMG and, test results such as back-emf measurements are given to confirm the design.

와이블데이터를 이용한 소형풍력발전기 출력에 대한 평가 (Evaluating the Output of Small-size Wind Power Generators Using Weibull Data)

  • 유기표;김영문
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.95-104
    • /
    • 2012
  • This study purposed to predict wind energy for small size wind power generators at 50m above the ground in each area using mean wind speed data for 10 minutes collected from 2001 to 2011 by meteorological data in large cities having over 60% of 15 story (50m) or higher apartments including Seoul, Daejeon, Gwangju and Daegu representing the inland region, and Busan, Incheon and Ulsan representing the coastal region. In the results of analysis, we confirmed close agree ment between observatory weather data and probability density distribution obtained using Weibull's parameters, and this suggests that Weibull's parameter is applicable to the estimation of wind energy. Hourly output energy using the mean wind speed for 10 minutes and output energy obtained from Weibull's parameter showed an error less than 5%, and thus it was found that wind energy can be evaluated using Weibull's modulus.

초고층 건물에서의 소형풍력발전시스템 적용에 관한 연구 (A Study on the Application of Small Wind Turbine System in Super High-rise Building)

  • 박영현;박정하;박진철;이언구
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.187-193
    • /
    • 2013
  • Thanks to the characteristic of high-rise buildings, the increase of wind speed according to the height of a building makes it possible to use high wind power resources, many countries led by some advanced nations are recently making steady and persistent effort in introducing small wind turbine systems as a step to lower electric power load in high-rise buildings. The aim of this research is to propose an optimum application process of a small wind turbine system in high-rise buildings. To achieve this goal, the case studies on the applications of high-rise and tall buildings were conducted and the best application among them was selected. On the basis of the case studies, an application process was proposed.

정전류·정전압 기능의 1kW급 하이브리드 PCS 설계 (Design of 1kW Hybrid CC/CV PCS)

  • 이재민
    • 디지털콘텐츠학회 논문지
    • /
    • 제14권4호
    • /
    • pp.529-536
    • /
    • 2013
  • 태양광 풍력 하이브리드(Hybrid) 발전 시스템에서는 발전의 주 인자인 태양의 일조량과 바람의 세기 등이 환경적 요인으로 적절하지 못할 경우 충방전 성능의 한계를 가지고 있는 에너지 저장장치인 배터리를 충전하는데 어려움이 발생한다. PCS(power conditioning system)는 태양광 풍력 발전 시스템 운용에 필수적인데 기존의 대부분의 PCS는 중대형 중심이어서 소형 발전에 적합하지 않아 효율이 높고 안정적인 동작을 하는 소형 발전용 PCS 개발이 절실히 요구된다. 본 논문에서는 이러한 문제들을 해결하면서 상용(한전)전력과의 계통연계 및 독립 운영이 가능하고 배터리의 장수명화와 안정화가 가능한 1kW급 하이브리드 CC/CV(constant current/constant voltage)기능을 갖는 PCS를 설계하고 시제품으로 구현하여 그 성능을 검증한다.

도서지역 소형풍력발전기 에너지 발생량 평가 (Evaluation of Energy Production for a Small Wind Turbine Installed in an Island Area)

  • 장춘만;이종성;전완호;임태균
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.558-565
    • /
    • 2013
  • This paper presents how to determine AEP(Annual Energy Production) by a small wind turbine in DuckjeokDo island. Evaluation of AEP is introduced to make a self-contained island including renewable energy sources of wind, solar, and tidal energy. To determine the AEP in DuckjeokDo island, a local wind data is analyzed using the annual wind data from Korea Institute of Energy Research firstly. After the wind data is separated in 12-direction, a mean wind speed at each direction is determined. And then, a small wind turbine power curve is selected by introducing the capacity of a small wind turbine and the energy production of the wind turbine according to each wind direction. Finally, total annual wind energy production for each small wind turbine can be evaluated using the local wind density and local energy production considering a mechanical energy loss. Throughout the analytic study, it is found that the AEP of DuckjeokDo island is about 2.02MWh/y and 3.47MWh/y per a 1kW small wind turbine installed at the altitude of 10 m and 21m, respectively.

전자기 손실을 고려한 소형 외전형 영구자석 풍력발전기의 성능 평가 (2) - 전자기 손실 해석 및 성능 평가 - (Performance Evaluation of Small-Scaled Wind Power Generator with Outer Permanent Magnet Rotor considering Electromagnetic Losses (2) - Electromagnetic Losses and Performance Analysis -)

  • 고경진;장석명;최장영
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.50-62
    • /
    • 2011
  • In this paper, analytical techniques for performance characteristics analysis of wind power generator with outer permanent magnet rotor are proposed. Furthermore, the proposed analytical techniques are validated by performance experiments of the manufactured generator. In this part, characteristic equations of losses such as copper loss, core loss are derived. Using the derived loss characteristic equations, electrical parameters obtained in [15] and d-q axes method, constant load and constant speed characteristics of wind power generator are analyzed. And then, to analyze performance of wind power system according to wind speed, d-q analysis model considering wind turbine characteristics is proposed. Finally, the obtained performance characteristics results are validated in comparison with those by experiments.

소형 직접구동형 풍력발전기의 최대 출력제어 (Maximum Power Control of Small Direct-Drive Wind Power Generator)

  • 김철호;이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.875-877
    • /
    • 2004
  • Research related to renewable energy is urgently required to cope with the depletion of fossil fuel and the environmental pollution. This paper deals with maximum power control of 1kW rating wind power generator. To implement direct-drive generator, axial flux permanent magnet generator is adopted to test the converter. The blade is attached to the surface of outer rotor disk. Generally wind power generator is operated under the rated wind speed. To capture maximum power at my given wind speed, the coordination of generator and converter is essential. Buck/Boost converter is designed to charge 24V battery and under the low wind speed it operates as boost converter.

  • PDF

도시형 소형 수직축 풍력 발전기의 형태별 성능에 대한 실험적 고찰 (Experimental study on the performance of urban small vertical wind turbine with different types)

  • 강덕훈;신원식;이장호
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.64-68
    • /
    • 2014
  • This paper is intended to provide experimental data for the design of the small VAWT(vertical axis wind turbine). Three types(lift, drag, and hybrid) of the blade of VAWT are tested with digital wind tunnel in this study. From the test, the relation of power coefficient and tip speed ratio for the blades are evaluated and compared each other depending on the blade type. Especially, the characteristics of hybrid blade which is shown to be expanded in the market without any logical data is proposed in the relation of power coefficient and tip speed ratio. It is shown that the hybrid blade can be used to make higher starting torque with trade off of degradation of power coefficient.

Performance and Flow Condition of Cross-Flow Wind Turbine with a Symmetrical Casing Having Side Boards

  • Shigemitsu, Toru;Fukutomi, Junichiro;Toyohara, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.169-174
    • /
    • 2016
  • A cross-flow wind turbine has a high torque coefficient at a low tip speed ratio. Therefore, it is a good candidate for use as a self-starting turbine. Furthermore, it has low noise and excellent stability; therefore, it has attracted attention from the viewpoint of applications as a small wind turbine for an urban district. However, its maximum power coefficient is extremely low (10 %) as compared to that of other small wind turbines. In order to improve the performance and flow condition of the cross-flow rotor, the symmetrical casing with a nozzle and a diffuser are proposed and the experimental research with the symmetrical casing is conducted. The maximum power coefficient is obtained as $C_{pmax}=0.17$ in the case with the casing and $C_{pmax}=0.098$ in the case without the casing. In the present study, the power characteristics of the cross-flow rotor and those of the symmetrical casing with the nozzle and diffuser are investigated. Then, the performance and internal flow patterns of the cross-flow wind turbine with the symmetrical casings are clarified. After that, the effect of the side boards set on the symmetrical casing is discussed on the basis of the analysis results.