• 제목/요약/키워드: small water system

Search Result 1,321, Processing Time 0.03 seconds

The Development of Nonvolatile Residue (NVR) Particle Monitoring System in Ultra Pure Water (초순수 물(Ultra Pure Water)내 비휘발성 잔류 물질(Nonvolatile Residue, NVR)의 모니터링을 위한 NVR 측정시스템의 개발)

  • Chung, Hyeok;Ahn, Jin-Hong;Ahn, Kang-ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.1
    • /
    • pp.55-59
    • /
    • 2010
  • In this study, we developed nonvolatile residue (NVR) real-time monitoring system to measure the nonvolatile residue particle in ultra pure water (UPW). This device has a capability of measuring 4 different channels, i.e., 10 nm, 30 nm, 50 nm, and 100 nm. Until now, the light scattering method to detect RAE(residue after evaporation) was the only choice. However, this method can detect RAE larger than ca. 50 nm. In ultra pure water, RAE particles are usually very small and hard to detect with conventional laser scattering devices. To detect very small RAEs, a new system is developed and tested. The system consists of an atomizer that generates RAE particles and a four channel condensation particle counter (CPC). During the several months' operation in manufacturing line, the system was successfully tested and showed reliable results.

Comparison of Daily Soil Water Contents Obtained by Energy Balance-Water Budget Approach and TDR

  • Rim, Chang-Soo
    • Korean Journal of Hydrosciences
    • /
    • v.8
    • /
    • pp.57-68
    • /
    • 1997
  • The daily soil water contents were obtained from the time domain reflectometry(TDR) method and energy balance-water budget approach with eddy correlation at the two small semiarid watersheds of Lucky Hills and Kendall during the summer rainy period. There was a comaprison of daily soil water content measured and estimated from these two different approaches. The comparison is valuable to evaluate the accuracy of current soil water content measuring system using TDR and energy balance-water budget approach using eddy correlation method at a small watershed scale. The degree of simiarity between the regressions of these two methods of measuring soil water content was explained by determining the correlations between these methods. Simple linear regression analyses showed that soil water content measured from TDR method was responsible for 58% and 63% of the variations estimated from energy balance-water budget approach with edy correlation at Lucky Hills and Kendall, respectively. The scatter plots and the regression analyses revealed that two different approaches for soil water content measurement at a small watershed scale have no significant difference.

  • PDF

Treatability Prediction Method for Nanofiltration Systems in Drinking Water Treatments (정수처리에 이용되는 나노여과막시스템의 성능예측방법 확립)

  • Kang, Meea;Itoh, Masaki
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.572-581
    • /
    • 2005
  • This research is conducted to develop predictable method of real scale nanofiltration treatability with small scale nanofiltration experiments. As a result of comparing calculated values with measured values, they are in a good agreement for the concentrations in filtered water and concentrated water. The results of that are not affected by change of system recovery from 20% to 95%. The proposed method is produced using constant recovery of elements, that is, no considering the pressure change. we can predict filtrated flux and contaminant concentrations with the method. The method has the following steps. (1) Calculate recovery of each element with water quality level after fixing recovery elements, (2) Predict system recovery with recovery of elements in 1, 2, 3, and 4 banks, (3) Run small scale nanofiltration experiments in predicted water quality and (4) Simulate large scale nanofiltration system for forecasting actual water quality. As the cost for nanofiltration pretest will reduced if we use the proposed method, it will be a promising method for introducing nanofiltration to supply safe drinking water.

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Trouble and Measure Owing to Water-hammer in Small Hydropower Turbine System Of Waterpipe (수도관로 소수력발전설비에 수격작용으로 인한 고장대책)

  • Lee, Hyoung-Mook;Kim, Ki-Won;Byun, Il-Hwan;Hong, Jeong-Jo;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.671-672
    • /
    • 2006
  • Recently the development of small hydropower generation with using water pipes is revitalized by the water works facilities. However, when the tubine generator is in case of emergency stop by the internal and external accidents, it causes water hammer in water pipes and suspension of water supply. To prevent these problems of small hydropower generator, we has analyzed water supply patterns, installation position and water pipe systems.

  • PDF

Development of Storage Management System for Small Dams (소규모 댐의 저수관리 시스템 개발)

  • Kim, Phil-Shik;Kim, Sun-Joo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.15-25
    • /
    • 2005
  • Ninety tow percent of over 1,800 gate controlled dams in Korea are classified as small dams. The primary purpose of these small dams is to supply irrigation water. Therefore, while large dams can store as much as 80 percent of precipitation and thus are efficient to control flood, small dams are often lack of flood control function resulting in increased susceptibility drought and flood events. The purpose of this study is to develope a storage management model for irrigation dams occupying the largest portion of small dams. The proposed Storage Management Model (STMM) can be applied to the Seongju dam for efficient management. Besides, the operation standard is capable of analyzing additional available water, considering water demand and supply conditions of watershed realistically. And the model can improve the flood control capacity and water utilization efficiency by the flexible operation of storage space. Consequently, if the small dams are managed by the proposed Storage management model, it is possible to maximize water resources securance and minimize drought and flood damages.

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

Studies on the flow stabilization around the turbine suction with utilizing the surface water overflow at small-hydraulic power plant (표층수의 월류를 통한 소수력빌전소 수차터빈측의 유동안정화 연구)

  • Lee, Sungmyung;Kim, Cheolhan;Yoo, Gunjong;Kim, Wonseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.165.2-165.2
    • /
    • 2011
  • Flow with suction to water turbine must be in stable state at small hydraulic power plant. But because of water level fluctuation and water gate effect according to irregular supply of cooling water, it would happen to produce bubble and vortex and finally lead to problems in power-plant system. With utilizing the concept design of double size gate, surface water overflowed the overhead of gate for stable flow at suction. We developed the overflow condition and analyzed the design factor with existed one such as water level(overflow amount) and overhead of water gate(overflow figure). Flow test and CFD simulation say that flow have stable state around suction and 20% of wave reduction effect at surface layer after surface water overflow.

  • PDF

Overview and Trend of Small Hydropower Development in Korea (국내 소수력발전 기술개발 현황과 전망)

  • Lee, G.B.;Lee, E.W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.735-741
    • /
    • 2005
  • We have studied the prearranged plan and the economy of a candidate site for the development of small hydro power. And also we have confirmed its economy by suggesting the technology of the unmanned operation and the selection of the water turbine generator which has a great efficiency, working rate and suitability to the topographical characteristics of various development sites, for example, irrigation reservoirs, water works pipes, sewage systems and cooling water of a steam power station. We proposed some opinions such as the better improvement of small hydropower industry the people' view, cooperation among industry/university/ research institutes, remote control/maintenance and goverment's legislature and supporting system etc.

  • PDF

A Study on Distribution of Small Hydropower Resources Using GIS (지리정보시스템을 이용한 소수력자원 분포 연구)

  • Park, Wansoon;Lee, Chulhyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.203-203
    • /
    • 2010
  • Small hydropower is one of the many types of new and renewable energy, which South Korea is planning to develop, as the country is abundant in endowed resources. In order to fully utilize small hydropower resources, there is a need for greater precision in quantifying small hydropower resources and establish an environment in which energy sources can be discovered using the small hydropower geographic information system. This study has given greater precision to calculating annual electricity generation and installed capacity of small hydropower plants of 117 medium basins by inquiring into average annual rainfall, basin area and runoff coefficient, which is anticipated to promote small hydropower resources utilization. Small hydropower geographic information system was also established by additionally providing base information on quantified small hydropower resources and analysis function and small hydropower generator status, rivers, basin, rainfall gauging station, water level gauging station etc.. Established system of GIS small hydropower energy can be used gather basic information for positive applications of small hydropower energy nationwide.

  • PDF