• 제목/요약/키워드: small water system

검색결과 1,317건 처리시간 0.029초

고신뢰 무선센서네트워크를 이용한 실시간 수질 모니터링 시스템 (Real-time Water Monitoring System for Small Water Supply Facility using High Reliable Wireless Sensor Network)

  • 강호용;장윤선
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.331-341
    • /
    • 2015
  • In this paper, real-time water quality monitoring system of small water supply facilities based on IEEE 802.15.4e-2012 DSME MAC and IEEE 802.15.4g-2012 PHY standard is presented, which is capable to acquire for highly reliable water quality information in the wide outdoor areas for effective water quality management of small water quality facilities is distributed in the long distance and remote areas. Previously, Long distance transmission is difficult in most water quality sensor module is using RS-485 protocol. But with this system, even in harsh outdoor environment, it is possible to establish a radio wave sensor in a wide area network, and not only water quality sensor shall be connected to the wireless system, but also wireless integrated management system shall provide more effective way of management of the numerous small water supply facilities spread throughout the community, so that the administrator can remotely monitor the data of water turbidity, pH, residual chlorine in the water-supply, water-level, and generate alarm to cope with risks. The management of small water facilities is done by residents will be very effective to notice water quality information of small water facilities to residents.

소규모 댐의 효과적 운영을 위한 저수관리 기법 개발 (Development of Storage Management Method for Effective Operation of Small Dams)

  • 김필식;김선주
    • 한국농공학회논문집
    • /
    • 제48권2호
    • /
    • pp.27-35
    • /
    • 2006
  • Large dams are managed with operation standard and flood forecasting systems, while small dams do not have management method generally. Shortage of water resources and natural disasters due to drought and flood raised public concerns for management of small dams. Most of small dams are irrigation dams, which need diversified water uses. However, the lack of systematic management of small dams have caused serious water wastage and increased natural disasters. Storage management method and system were developed to solve these problems in small dams. The system was applied to Seongju dam for effective management. The storage management method was established considering hydrology simulation and statistical analysis using the system. This method can bring additional available water, even in the same conditions of the water demand and the supply conditions of watershed. It can improve the flood control capacity and water utilization efficiency by' the flexible operation of storage space.

실제 상수관망에 대한 모니터링 지점선정방법의 적용 (Application of the Determination Method of Monitoring Location in Real Water Distribution System)

  • 박용균;정성균;권혁재
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.617-623
    • /
    • 2015
  • In this study, determination methods of monitoring location in water distribution system were suggested and applied to real test bed. Small block of Gwangtan water distribution system is consisted of 582 pipes, 564 junctions, 1 reservoir, and 1 pump station. Small block of Ho Chi Minh water distribution system is consisted of 162 pipes, 148 junctions, and 1 reservoir. Two small block water distribution systems were analyzed by pressure contribution analysis method to determine the optimum monitoring locations. The pressure change was estimated at each junctions by the additional demand at a junction. From the results, the optimum monitoring location can be determined by rank of pressure contribution index at each junctions due to demand change at a junction.

간이상수도에서 물과 약품의 혼합방법 (Mixing Method of Water and Chemicals in a Small-Scale Water Supply System)

  • 유영현;기현;최종욱;김성초;김정수;김용선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3128-3133
    • /
    • 2007
  • The mixing method of water and chemicals is significant in a small-scale water supply system because drinking water should be supplied with a certain quantity of remaining chemicals maintained. In the present study, the concentration distribution and the mixing index were obtained from four models, which were to find out the optimal mixing method of water and chemicals. The two models brought the good mixing effects out of the four, one for providing chemicals from the center of water supply pipe and the other for setting up the semicircle block at the downstream of the chemicals-providing pipe. As a result, the mixing effect was found out to be increased due to the diffusion and the disturbance of flows. In conclusion, these results are expected to contribute to designing the optimal mixing system.

  • PDF

방류수의 수위 및 유량 분석을 통한 해양 소수력 성능평가 (Performance Evaluation of Ocean Small Hydropower Plant by Analyzing Water Level and Flow Rate of Circulating Water)

  • 강금석;김지영;유무성
    • 신재생에너지
    • /
    • 제5권3호
    • /
    • pp.32-39
    • /
    • 2009
  • The Samcheonpo ocean small hydropower plant (SHP) has a special feature of using marginal hydraulic head of circulating water system of fossil fuel power plant as a power source and having the characteristics of general hydropower generation and tidal power generation as well. Also, it contributes to reducing green house gases and developing clean energy source by recycling circulating water energy otherwise dissipated into the ocean. The efficiency of small hydropower plant is directly affected by effective head and flow rate of discharged water. Therefore, the efficiency characteristics of ocean hydropower plant are analyzed with the variation of water level and flow rate of discharged water, which is based on the accumulated operation data of the Samcheonpo hydropower plant. After the start of small hydropower plant operation, definite rise of water level was observed. As a result of flow pattern change from free flow to submerged flow, the instability of water surface in overall open channel is increased but it doesn't reach the extent of overflowing channel or having an effect on circulation system. Performance evaluation result shows that the generating power and efficiency of small hydropower exceeds design requirements in all conditions. Analysis results of CWP's water flow rate verify that the amount of flowing water is measured less and the highest efficiency of small hydropower plant is achieved when the effective head has its maximum value. In conclusion, efficiency curve derived from water flow rate considering tidal level shows the best fitting result with design criteria curve and it is verified that overall efficiency of hydropower system is satisfactory.

  • PDF

수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안 (The Optimum Control Study for Improving Efficiency of the Small Hydropower Generation in Water Pipe)

  • 홍정조;임동희;김수상
    • 신재생에너지
    • /
    • 제4권2호
    • /
    • pp.31-38
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with 00 hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

농촌지역 간이상수도 수질에 대한 수리지화학적 특성: 충남 금산군 일대

  • 이진수;고경석;김용재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.369-372
    • /
    • 2004
  • This study presents the hydrogeochmical investigation to know the effect of geology and sources for water quality in small potable water supply system at rural area. The results of water quality in Geumsan area showed the 3.2% of water samples exceeded the limit of drinking water standard by bacteria. The hydrochemical investigation results indicated the high EC, Ca and HCO$_3$ in surface water and metasedimentary rocks and this is caused by the dissolution of calc-slicate minerals of metasedimentary rocks.

  • PDF

소규모 무인급수 가압장 원격제어시스템 (Remote Control System of the Uninhabited Small Water Booster Supply)

  • 이경;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1997-1998
    • /
    • 2006
  • In this paper, we propose a remote control system which is used by internet network system in the small water booster supply. So far, TMTC(Tele Metering Tele Control) has been used to control and monitor small water booster pump. But it is possible and easy to control and observe local booster panel with the rapid development of internet, This new system is to provide operators and managers with sufficient information and control in order to implement the operation in an efficient and economical way. This system consists of three parts that are controller, netpump server and netview client. Controller has a dual architecture. The motive for installing controller is the continuous production and supply of drinking water.

  • PDF

소구경 터널에 사용되는 SHOT PATCH용 모르타르의 특성 (Properties of the SHOT PATCH Mortar a Wet System for Small Bore Tunnels)

  • 정민철;전용희;정종익;박길수
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.121-128
    • /
    • 1999
  • The SHO PATCH System Mortar is a mortar shotcreting system which uses fairly small machine and equipment, and is applied for shotcrete tunnel linings, in particular for small bore tunnels of aqueducts by the TBM(Tunnel Boring Machine) method, and for reparing tunnels suffering from spring water and deterioration. This study shows the characteristics of the new mortar shotcreting system, the SHOT PATCh System Mortar, which exhibits excellent shotcrete performance.

마을단위 소규모 하·폐수처리 공정의 효율적 유지관리를 위한 전문가 시스템에 관한 연구 (An Innovative Expert System for the Maintenance of On-site Wastewater Treatment Process for Small-scale Residential and Commercial Sites)

  • 김승준;최용수;홍석원;권기한;정익재
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.132-140
    • /
    • 2005
  • The pilot test of a new alternative for small wastewater treatment system has been conducted for two years. It consists of a hybrid bioreactor and the expert system including the process control logic, PLC system, and HMI for the process automation. In order to monitor and remote control its status, the real-time data was transferred from the on-site control center to the central station via a wireless local area network. More efficient and stable performances were observed at automatic operating mode compared with the manual. On an average, COD, SS, T-N and T-P concentrations in the effluent from the hybrid bioreactor were less than 14, 7, 12 and 0.9 mg/L, respectively. According to the result from pilot tests, the quality of treated wastewater with sand filtration was enough to be utilized again.