• 제목/요약/키워드: small studs

검색결과 14건 처리시간 0.024초

Effect of local small diameter stud connectors on behavior of partially encased composite beams

  • Nguyen, Giang Bergerova;Machacek, Josef
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.251-266
    • /
    • 2016
  • The paper combines two distinct parts. First the behavior of welded headed studs with small diameters of 10 and 13 mm acting as shear connectors (which are not embraced in current standards) is studied. Based on standard push tests the load-slip relationships and strengths are evaluated. While the current standard (Eurocode 4 and AISC) formulas used for such studs give reasonable but too conservative strengths, less conservative and full load-slip rigidities are evaluated and recommended for a subsequent investigation or design. In the second part of the paper the partially encased beams under bending are analyzed. Following former experiments showing rather indistinct role of studs used for shear connection in such beams their role is studied. Numerical model employing ANSYS software is presented and validated using former experimental data. Subsequent parametric studies investigate the longitudinal shear between steel and concrete parts of the beams with respect to friction at the steel and concrete interface and contribution of studs with small diameters required predominantly for assembly stages (concreting). Substantial influence of the friction and effect of concrete confinement was observed with rather less noticeable contribution of the studs. Distribution of the longitudinal shear and its sharing between friction and studs is presented with concluding remarks.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.

초음파진행 시간차에 의한 STUD[BOLT] 나사산의 미세한 결함검출 (Ultrasonic Detection of Small Crack in Studs[Bolts] by Time Difference of Thread Signals(TDTS))

  • 서동만;박대영;김종교
    • 비파괴검사학회지
    • /
    • 제10권1호
    • /
    • pp.38-46
    • /
    • 1990
  • It is difficult to detect such flaws as stress - corrosion cracking or corrosion wastage(loss of bolt diameter) in the threads. In many cases the critical size of a flaw is very small(1-2 mm order). This paper describes how it is possible to discriminate small flaw indications in threads using the time difference or thread signals(TDTS) by a signal-conditioning technique.

  • PDF

원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발 (Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant)

  • 서동만;박문호;홍순신
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

초음파의 시그날콘디쇼닝에 의한 STUD[BOLT] 나사산의 미세결함 검출 (Ultrasonic Detection of Small Crack in Studs[Bolts] by Signal-Conditioning)

  • 서동만;문홍진;최규훈;김종교
    • 한국음향학회지
    • /
    • 제9권3호
    • /
    • pp.31-41
    • /
    • 1990
  • 나사산에 존재하는 Stress-Corrosion Cracking이나 Corrosion Wastage(Loss of Bolt Diameter)는 검출하기가 어렵다. 결함의 크기가 1-2mm 정도에 이르면 성장이 급진전되어 파손에 이르는 경우가 많은데 본 논문에서는 Signal-Conditioning 기법에 통한 나사산신호의 시간차를 이용해서 매우 작은 결함도 쉽게 찾을 수 있는 방법에 관해 연구되었다.

  • PDF

물/유기용매 불혼합 이성분계에서의 반응염색(Ⅱ) - C. I. Reactive Blue 203을 이용한 견섬유의 염색 - (Reactive Dyeing in Immiscible Two-phase System of Water/Organic Solvent(Ⅱ) - The Dyeing of Silk with C. I. Reactive Blue 203 -)

  • 김태경;김미경;임용진;조광호
    • 한국염색가공학회지
    • /
    • 제13권2호
    • /
    • pp.42-42
    • /
    • 2001
  • Following the prior studs regarding that 1.0g of cotton fabric cound be dyed uniformly with a reactive dye in the solvent mixture of 2㎖ of water and 23㎖ of dichloromethane, silk fabric was dyed with C. I. Reactive Blue 203 in the water/dichloromethane two-phase immiscible solvent media. In order to minimize dye loss due to its hydrolysis, the reactive dyeing was carried out in dichloromethane containing a small amount of water. With only 3㎖ of water in 22㎖ of dichloromethane, 1.0g of silk fabric could be dyed perfectly. The uptake ratio was increased greatly, compared with that of normal reactive dyeing in a water medium. It would seem that the one of hydrophobic solvents, dichloromethane, can assist the even dyeing as it disperses a small amount of dye-dissolved water phase and conveys this water phase to the fabric entirely and uniformly.

물/유기용매 불혼합 이성분계에서의 반응염색(II) - C. I. Reactive Blue 203을 이용한 견섬유의 염색 - (Reactive Dyeing in Immiscible Two-phase System of Water/Organic Solvent (II) - The Dyeing of Silk with C. I. Reactive Blue 203 -)

  • 김태경;김미경;임용진;조광호
    • 한국염색가공학회지
    • /
    • 제13권2호
    • /
    • pp.128-134
    • /
    • 2001
  • Following the prior studs regarding that 1.0g of cotton fabric round be dyed uniformly with a reactive dye in the solvent mixture of $2m\ell$ of water and $23m\ell$ of dichloromethane, silk fabric was dyed with C. I. Reactive Blue 203 in the water/dichloromethane two-phase immiscible solvent media. In order to minimize dye loss due to its hydrolysis, the reactive dyeing was carried out in dichloromethane containing a small amount of water. With only $3m\ell$ of water in $22m\ell$ of dichloromethane, 1.0g of silk fabric could be dyed perfectly. The uptake ratio was increased greatly, compared wish that of normal reactive dyeing in a water medium. It would seem that the one of hydrophobic solvents, dichloromethane, can assist the Even dyeing as it disperses a small amount of dye-dissolved phase and conveys this water phase to the fabric entirely and uniformly.

  • PDF

Ultrasonic Detection of Cracks in Studs and Bolts Using Dynamic Predictive Deconvolution and Wave Shaping

  • Suh, Dong-Man;Kim, Whan-Woo;Kim, Dae-Yen;Chung, Jin-Gyun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권1E호
    • /
    • pp.44-53
    • /
    • 1998
  • Bolt degradation has become a major issue in the nuclear industry since the 1980's due to failure during operation. If small cracks in stud bolt are not detected early enough, they grow rapidly and cause catastrophic disasters. Their detection, despite its importance, is known to be a very difficult problem due to the complicated structures of the stud bolts. This paper presents a method of detecting and sizing a small crack in the root between two adjacent crests in threads. The key idea is from the fact that the Rayleigh wave propagates slowly along a crack from the tip to the opening and is reflected from the opening mouth. When there exists a crack, a small delayed pulse due to the Rayleigh wave is detected between large regularly spaced pulses from the thread. The delay time is the same as the propagation delay time of the slow Rayleigh wave and is proportional to the size of the crack. To efficiently detect the slow Rayleigh wave, three methods based on digital signal processing are proposed : modified wave shaping, dynamic predictive deconvolution, and dynamic predictive deconvolution combined with wave shaping.

  • PDF

Lateral Resistance of Reinforced Light-Frame Wood Shear Walls

  • Hyung Woo LEE;Sang Sik JANG
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권1호
    • /
    • pp.58-66
    • /
    • 2023
  • In light-frame timber construction, the shear wall is one of the most important components that provide resistance to lateral loads such as earthquakes or winds. According to KDS (Korea Design Standard) 42 50 10, shear walls are to be constructed using wood-based structural sheathing, with studs connected by 8d nails spaced 150 mm along the edge and 300 mm in the field. Even though small-scale residential timber building can be designed to exhibit seismic resistance using light-frame timber shear walls in accordance with KDS 42 50 10, only the abovementioned standard type of timber shear wall is available. Therefore, more types of timber shear walls composed of various materials should be tested to measure their seismic resistance, and the results should be incorporated into the future revision of KDS 42 50 10. In this study, the seismic resistance of shear walls composed of structural timber studs and wood-based structural sheathing with reinforced nailing is tested to evaluate the effects of the reinforcement. For the nailing reinforcement, shear wall specimens are constructed by applying nail spacings of 75-150 mm and 50-100 mm. For the shear wall specimens with one sheathing and reinforced nailing, the shear strengths are 1.7-2.0 times higher than that of the standard shear wall (nail spacing of 150-300 mm). The shear strength of the shear walls with sheathing on both sides is 2.0-2.7 times higher than that of the standard shear wall.

세부목골조로 구성된 전통목골조 벽체 전단저항능력 (Shear Resistance Capacity Length of Traditional Wooden Frame's Wall divided into Small Frame)

  • 황종국;권양희;배동훈
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.11-18
    • /
    • 2019
  • The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of $38mm{\times}89mm$ at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values larger than 1.0 even though they have openings, most of them show values smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.