• Title/Summary/Keyword: small hole

Search Result 487, Processing Time 0.02 seconds

A study on improvement of 2. 3. 5-Triphenyl Tetrazolium Chloride(TTC) reduction test : disc plate method (2. 3. 5-Triphenyl Terazolium Chloride(TTC) 환원시험법의 개선에 관한 연구 : disc plate method)

  • 정동수;김동훈;이상목
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.2
    • /
    • pp.163-176
    • /
    • 1995
  • Triphenyl Tetrazolium Chloride(TCC) reduction test is simple and sensitive to some residual antibiotics (especially to penicillin) in milk, but comparatively insensible to sulfo-namides. The volumn of sample is also large. Thus this study was undertaken to increase the detectable level of sulfonamides in raw milk. In this study, we used small transparent plastic hole and pulp disc instead of 10m1 test tube and made test medium in which was added 0.08%TTC, 0.3% agar, 10% skim milk, approximately $10^6$ CFU/ml streptococcus thermophilus and 5ppm Trimethoprim to enhance the sensitivity for sulfonamides The results of TCC reduction test by disc plate method were summarized as follows : 1. sensitivity to residual sulfonamides were much higher than official TCC reduction test. Detectable limites of sulfamethazine, sulfamerazine, sulfathiazole, sulfachloropy-ridazine, sulfadimethoxine, sulfamononethoxine, sulfadiazine and sulfaquinoxaline were 0.1-0.5ppm levels. 2. Detectable limites to some antibiotics were simillar or good than that of official method as 0.005-0.1ppm to three ${\beta}$ -lactams, 0.25-0.5ppm to one macrolide, 2-10ppm to three aminoglycosides, 0.2-0.5ppm to three tetracycline, 0.1-0.5ppm to chloramphenicol. 3. Only 0.1ml of milk was needed to test and the test medium could be stored appnoximatly 7days in the refrigerator. So test procedure was convenient than offcial method. 4. These results suggest that disc plate method is more useful to detect bacterial growth inhibition substances including sulfonamides in raw milk.

  • PDF

An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-1) (지하수류가 밀폐형 천공 지중열교환기 성능에 미치는 영향(1))

  • Hahn, Jeong Sang;Hahn, Chan;Yoon, Yun Sang;Kiem, Young Seek
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.64-81
    • /
    • 2016
  • To analyze the influence of various groundwater flow rates (specific discharge) on BHE system with balanced and unbalanced energy loads under assuming same initial temperature (15℃) of ground and groundwater, numerical modeling using FEFLOW was used for this study. When groundwater flow is increased from 1 × 10−7 to 4 × 10−7m/s under balanced energy load, the performance of BHE system is improved about 26.7% in summer and 22.7% at winter time in a single BHE case as well as about 12.0~18.6% in summer and 7.6~8.7% in winter time depending on the number of boreholes in the grid, their array type, and bore hole separation in multiple BHE system case. In other words, the performance of BHE system is improved due to lower avT in summer and higher avT in winter time when groundwater flow becomes larger. On the contrary it is decreased owing to higher avT in summer and lower avT in winter time when the numbers of BHEs in an array are increased, Geothermal plume created at down-gradient area by groundwater flow is relatively small in balanced load condition while quite large in unbalanced load condition. Groundwater flow enhances in general the thermal efficiency by transferring heat away from the BHEs. Therefore it is highly required to obtain and to use adequate informations on hydrogeologic characterristics (K, S, hydraulic gradient, seasonal variation of groundwater temperature and water level) along with integrating groundwater flow and also hydrogeothermal properties (thermal conductivity, seasonal variation of ground temperatures etc.) of the relevant area for achieving the optimal design of BHE system.

A Study on the behaviour of Cavitation erosion and lubricating Oils and the influence of Corrosion on Slide Bearing Metals for Internal combustion Engine (내연기관용 슬라이드 베어링재의 케비테이션 침식거동과 부식영향 및 윤할유의 거동에 관한 연구)

  • Lee, Jin-Yeol;Im, U-Jo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.2
    • /
    • pp.171-183
    • /
    • 1992
  • In this paper, the behaviour of cavitation erosion, influence of corrosion and corrosion control on slide bearing metals for internal combustion engine were investigated, and this experiment was done by the vibratory cavitation erosion tester. The main results obtained are as follows: 1. With decreasing the space between horn and specimen, the weight loss and its rate increased step by step. But the weight loss and its rate of 0.2mm space decreased conversely more than that of 0.4mm space at early stage. 2. The weight loss and its rate with change of pH were appeared to the order of pH2>pH12>pH7>pH4. And the weight loss and its rate at pH 4 decreased at best. 3. The weight loss and its rate by cavitation erosion for bearing metals were shown to the order of W.M7>W.M1>K.M4. 4. There appeared mainly small pit hole at pH2, and appeared the pit of netting thread type at pH12 by the results of the damaged surfaces at pH2 and pH12 environments that were sensitive to cavitation erosion. 5. With increasing the viscosity of lubricating oil, the weight loss rate by cavitation erosion became dull at the space below 0.5mm. 6. The protective efficiency of cavitation erosion-corrosion is superior inhibitor of chormate(25 ppm) to cathodic protection.

  • PDF

A Study on the Foundations of Wooden Pagodas of 'Kokubunji' in Japan (일본 국분사 목탑의 하부구조 고찰)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.19 no.5
    • /
    • pp.81-98
    • /
    • 2010
  • In the middle of the 8th century, we met the new high-rise building, the 7th storied wooden pagodas in 'Kokubunji' in Japan. I tried to analyze and study this building to show how the wooden pagoda had changed itself because of appearance of new style. The conculusions are as follows; 1. The construction of the foundation was mainly composed namely 'Panchuk'. It was proceeded by two ways. One is the earthen-digging, laying foundations named 'Gulkwangpachuk' and the other is simply laying foundation named 'Jisangpanchuk'. In that period, due to the progress of the technique, we assumed that the main stream is 'Jisangpanchuk'. 2. The elevation of base was mostly the single foundation from archaeological study. The material was stone. The middle case of pagoda had the base of tile-roofed. We knew the just one pagoda had the base of brick, but that was not main stream. 3. The new device had appeared in the central base stone. It was the stone point. But in that period the existing method, a hole style and the new style was used in the central base stone. This fact is showed that the central government was not hold the reigon(it names 'Kook') in the respect of the technique. 4. The plan scale is classified of 3 group. As a result, the first body is larger, the main-unit and the sub-unit is a equal unit. But smaller, the length of main-unit is longer than the one of sub-unit. And the very small pagoda was build in that period.

Effect of SiO2 Buffer Layer Thickness on the Device Reliability of the Amorphous InGaZnO Pseudo-MOS Field Effect Transistor (SiO2 완충층 두께에 따른 비정질 InGaZnO Pseudo-MOS Field Effect Transistor의 신뢰성 평가)

  • Lee, Se-Won;Hwang, Yeong-Hyeon;Cho, Won-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • In this study, we fabricated an amorphous InGaZnO pseudo-MOS transistor (a-IGZO ${\Psi}$-MOSFET) with a stacked $Si_3N_4/SiO_2$ (NO) gate dielectric and evaluated reliability of the devices with various thicknesses of a $SiO_2$ buffer layer. The roles of a $SiO_2$ buffer layer are improving the interface states and preventing degradation caused by the injection of photo-created holes because of a small valance band offset of amorphous IGZO and $Si_3N_4$. Meanwhile, excellent electrical properties were obtained for a device with 10-nm-thick $SiO_2$ buffer layer of a NO stacked dielectric. The threshold voltage shift of a device, however, was drastically increased because of its thin $SiO_2$ buffer layer which highlighted bias and light-induced hole trapping into the $Si_3N_4$ layer. As a results, the pseudo-MOS transistor with a 20-nm-thick $SiO_2$ buffer layer exhibited improved electrical characteristics and device reliability; field effective mobility(${\mu}_{FE}$) of 12.3 $cm^2/V{\cdot}s$, subthreshold slope (SS) of 148 mV/dec, trap density ($N_t$) of $4.52{\times}1011\;cm^{-2}$, negative bias illumination stress (NBIS) ${\Delta}V_{th}$ of 1.23 V, and negative bias temperature illumination stress (NBTIS) ${\Delta}V_{th}$ of 2.06 V.

A STUDY ON THE COMPLETE RETRIEVAL SYSTEM OF THE CEMENTATION TYPE IMPLANT ABUTMENT (손상 없이 영구 접착 보철물을 제거할 수 있는 cementation type 임플랜트 지대주 개발에 관한 연구)

  • Choi Jin-Ho;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.597-607
    • /
    • 2004
  • Purpose: This study was peformed to investigate the retrievability of the cemented crown from the cementation type implant abutment. Material and method: The cementation type implant abutments (NEOBIOTECH implant abutment regular, 3 degree taper, 10mm length, 4mm diameter, Ti grade III, machined surface. Hwasung, Kyunggi-do) and cemented crowns were divided into 3 groups, depending on their hole angles formed in the crowns for their retrievability. The abutments and crowns were luted with 4 kinds of cements and separation test using metal wedge was executed with Instron 4465 Universal Testing Machine and the maximum impact force of the modified crown ejector was measured. Results and conclusion : 1. All of the cementation type implant abutments and cemented crowns were separated with relatively small force by metal wedge. 2. The retrieving force was minimum when the metal wedge was applied perpendicular to the axis of abutment. 3. The force for retrieving crowns from abutments was maximum in resin cement group, and reduced in orders of zinc phosphate cement, glass ionomer cement and zinc oxide eugenol cement. 4. The maximum force obtained by the crown ejector was higher than the retrieval force in ZOE and GI cement and lower than that in ZPC and resin cement. 5. If it has similar conditions clinically, the cemented crowns luted with 2 types of cements (ZOE, GI cement) can be safely retrieved from the cementation type implant abutments by the modified crown ejector.

Analyses of the Environmental Characteristics of Ponds in Golf Courses for Ecological Management (골프장 연못의 생태적 관리를 위한 환경특성 분석)

  • Ahn Deug-Soo;Kim Chang-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.51-77
    • /
    • 2006
  • Pond management is a critical part of overall golf course management, both during growth and maintenance modes of turf care. This study investigated 48 ponds in nine 18- or 27-hole golf courses to analyze the environmental characteristics of ponds. The research process had three phases: (1) inventory and analysis of grading plans and drainage plans, (2) field verification and interviews with greenskeepers, and (3) analyses of water quality and statistics. All data were collected from May to August in 2004. The results of this study can be summarized as follows: 1. It is desirable to site a golf course in a small watershed with high watershed eccentricity to control storm water runoff efficiently and to minimize soil erosion during construction. 2. The siting and size of a pond should be determined through a land-use analysis of the watershed for the purpose of ecological management. The bigger the forest-to-golf course ratio, the better the water quality will be. 3. The size and capacity of each individual ponds varied and there were many somewhat longish rather than round ponds. 4. There were many differences among golf courses in naturalness of the ponds, and the correlation between naturalness and area of aquatic plants was very high. 5. Analyses of pond water quality indicated that the degrees of Dissolved Oxygen, Chemical Oxygen Demanded and Suspended Solids were relatively low values but Total Phosphorus and Total Nitrogen were too high. Therefore a systematic approach is needed to solve e problem. Pesticide residues were not detected in all ponds. 6. Water depth and area of hydrophyte should be considered when designing an ecological pond. 7. All ponds used storm water as a main source of water supply and added underground water. Aquatic plants and physical methods such as water aeration and spray fountains were the main choices for maintaining a healthy aquatic environment.

Structure and Superconducting Properties of Ba-substituted (Ru,Cu)(Sr,Eu)$_2$(Eu,Ce)$_2Cu_2O_z$ System (Ba 치환에 따른 (Ru,Cu)(Sr,Eu)$_2$(Eu,Ce)$_2Cu_2O_z$ 계의 초전도 특성)

  • Lee, H.K.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.12-17
    • /
    • 2011
  • We investigated the effects of Ba and Cu co-substitution on the structural and superconducting properties of ($Ru_{1-y}Cu_y$)($Sr_{1.67-x}Ba_xEu_{0.33}$)($Eu_{1.34}Ce_{0.66}$)$Cu_2O_z$ samples. X-ray diffraction(XRD) reveals that single-phase samples can be obtained in the range from x = 0.1 to 0.2 for ($Ru_{0.5}Cu_{0.5}$)($Sr_{1.67-x}Ba_xEu_{0.33}$)($Eu_{1.34}Ce_{0.66}$)$Cu_2O_z$ and from y = 0.25 to 0.5 for ($Ru_{1-y}Cu_y$)($Sr_{1.47}Ba_{0.2}Eu_{0.33}$)($Eu_{1.34}Ce_{0.66}$)$Cu_2O_z$, respectively. All samples with compositions of ($Ru_{0.5}Cu_{0.5}$)($Sr_{1.67-x}Ba_xEu_{0.33}$) ($Eu_{1.34}Ce_{0.66}$)$Cu_2O_z$ (x = 0 - 0.33) show superconducting transition behavior and the onset transition temperature decreases slightly with increasing x in consistent with the change of hole concentration estimated from room temperature thermoelectric power measurements. The XRD and resistivity measurements for the ($Ru_{1-y}Cu_y$)($Sr_{1.47}Ba_{0.2}Eu_{0.33}$)($Eu_{1.34}Ce_{0.66}$) $Cu_2O_z$ system indicate that the partial substitution of Cu for Ru is necessary to form phase pure samples, but result in a small change in transition temperature in the single-phase region from x = 0.25 to 0.5.

Hydraulic Eroperty of Groundwater Flow Controlled by Vertical Geologic Structure and its field Example (수직 지질구조에 의해서 지배되는 암반지하수 유동의 수리적 성질과 그 예)

  • 함세영;김형찬;임정웅
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.2
    • /
    • pp.101-109
    • /
    • 1998
  • Hydraulic property of fissured aquifers often depends on geologic structure which acts main channel of groundwater flow. We treated theories of linear flow related to vertical geologic structure. Then, we analyzed the result of two pumping tests conducted in Okmyeong-ri area (Kyeongbook province) using fractal model and found hydraulic characteristic of the fissured aquifer in this area. According to the pump test analyses, groundwater flow around the holes (pumping well D9; observation wells C3 and D7) of test 1 is linear. and is controlled by vertical geologic structure with infinite length and infinitesimally small width. On the other hand, around the hole D10 (pumping well) of test 2, groundwater flow is pseudo-radial (n=1.9) or radial (n=2). Thus, the characteristic of fractured aquifer often shows variable groundwater flow spatially and temporally.

  • PDF

Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures (캡슐 하단부 구조변경에 따른 압력강하 및 진동특성)

  • Choi, M.H.;Choo, K.N.;Cho, M.S.;Kim, B.G.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.12 s.105
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.