• Title/Summary/Keyword: small breast

Search Result 356, Processing Time 0.03 seconds

A Case of Small Cell Lung Cancer Metastastized to the Contralateral Breast (반대측 유방전이를 일으킨 폐소세포암 1례)

  • Park, Sung Chul;Kim, Seung Young;Lee, Sung Yong;Kim, Je Hyeong;Lee, Sang Yeub;Shin, Cheol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.1
    • /
    • pp.91-96
    • /
    • 2004
  • Primary lung cancer frequently metastasizes to distant organs. But breast is a very rare site of metastasis. So, accurate diagnosis is essential to rule out primary breast cancer. A 62-year old woman who had complained of cough was diagnosed as small cell lung carcinoma of the right lower lobe. She had a 2.5cm sized lobular mass in left upper mid portion of breast. Sonoguided breast biopsy revealed small cell carcinoma consistent with metastatis from primary lung cancer. She also had bone metastses to the scapula and the vertebrae. We report the case of metastatic breast cancer from small cell lung carcinoma.

Relation of mortality to DBH and available area in naturally germinated Pinus densiflora populations

  • Kato, Jun;Degawa, Yousuke
    • Journal of Ecology and Environment
    • /
    • v.37 no.2
    • /
    • pp.105-111
    • /
    • 2014
  • To elucidate whether small diameter at breast height correlates with tree death in an overcrowded tree population, we analyzed self-thinning occurring over the course of 37 years in naturally established Pinus densiflora populations in Sugadaira, central Japan. As trees grew, their diameters at breast height increased and the number of trees consequently decreased. Spatial distribution, which was initially clumped, changed accordingly, first becoming random and finally uniform. We calculated the "available area" of individual trees to elucidate the contribution of this parameter to tree mortality. Small diameter at breast height was strongly correlated with tree death, with a slight correlation observed between tree death and small available area of individual trees.

Elastography for Breast Cancer Diagnosis: a Useful Tool for Small and BI-RADS 4 Lesions

  • Liu, Xue-Jing;Zhu, Ying;Liu, Pei-Fang;Xu, Yi-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10739-10743
    • /
    • 2015
  • The present study aimed at evaluating and comparing the diagnostic performance of B-mode ultrasound (US), elastography score (ES), and strain ratio (SR) for the differentiation of breast lesions. This retrospective study enrolled 431 lesions from 417 in-hospital patients. All patients were examined with both conventional ultrasound and elastography. Two experienced radiologists reviewed ultrasound and elasticity images. The histopathologic result obtained from ultrasound-guided core biopsy or operation excisions were used as the reference standard. Pathologic examination revealed 276 malignant lesions (64%) and 155 benign lesions (36%). A cut-off point of 4.15 (area under the curve, 0.891) allowed significant differentiation of malignant and benign lesions. ROC (receiver-operating characteristic) curves showed a higher value for combination of B-mode ultrasound and elastography for the diagnosis of breast lesions. Conventional ultrasound combined elastography showed high sensitivity, specificity, and accuracy for group II lesions (10mm${\leq}20mm$). Elastography combined with conventional ultrasound show high specificity and accuracy for differentiation of benign and malignant breast lesions. Elastography is particularly important for the diagnosis of BI-RADS 4 and small breast lesions.

Brain metastasis in human epidermal growth factor receptor 2-positive breast cancer: from biology to treatment

  • Koo, Taeryool;Kim, In Ah
    • Radiation Oncology Journal
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Overexpression of human epidermal growth factor receptor 2 (HER2) is found in about 20% of breast cancer patients. With treatment using trastuzumab, an anti-HER2 monoclonal antibody, systemic control is improved. Nonetheless, the incidence of brain metastasis does not be improved, rather seems to be increased in HER2-positive breast cancer. The mainstay treatment for brain metastases is radiotherapy. According to the number of metastatic lesions and performance status of patients, radiosurgery or whole brain radiotherapy can be performed. The concurrent use of a radiosensitizer further improves intracranial control. Due to its large molecular weight, trastuzumab has a limited ability to cross the blood-brain barrier. However, small tyrosine kinase inhibitors such as lapatinib, has been noted to be a promising agent that can be used as a radiosensitizer to affect HER2-positive breast cancer. This review will outline general management of brain metastases and will focus on preclinical findings regarding the radiosensitizing effect of small molecule HER2 targeting agents.

Immediate Breast Reconstruction Placing the Breast Implant under the Pectoralis Major-Serratus Anterior Pocket without Tissue Expansion (조직확장술을 거치지 않고 유방보형물을 대흉근-전거근 포켓에 삽입한 즉시 유방재건술)

  • Kim, Hoon;Eom, Jin Sub;Ahn, Sei Hyun;Son, Byung Ho;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.622-627
    • /
    • 2007
  • Purpose: Although the autogenous tissue transfer has been the mainstay of the breast reconstruction, concern for the donor site morbidity can lead to the superseded method using tissue expander with implant or permanent expander-implant. However, the additional procedure of tissue expansion possibly cause discomfort and raise the cost. We tried to verify the efficacy of using the saline-filled breast implant by itself for the safe and convenient immediate breast reconstruction modality if the patients have small, round and non-ptotic breasts and the sufficient breast skin can be saved with mastectomy. Methods: From July 2002 to July 2005, 29 breasts of 26 patients were restored only with the saline-filled breast implant immediately after the skin sparing or nipple-areolar skin sparing mastectomy in Asan Medical Center. A pocket with pectoralis major and serratus anterior muscle was created and the implant was covered with this muscle pocket. Simultaneous contralateral augmentation was performed in patients whose mastectomy specimen weighed less than 100g. Results: Using only the saline-filled breast implant resulted in the successful reconstruction with few complications including partial necrosis of nipple areolar skin (five cases, 17.2%), capsular contracture (three cases, 10.3%), hematoma (one case, 3.4%), depigmentation of areolar skin (one case, 3.4%), hypertrophic scar (one case, 3.4%), which were all healed by conservative management. There were no significant complications such as implant exposure and subsequent removal. Conclusion: Immediate breast reconstruction only with the saline-filled breast implant can be a satisfactory alternative option for the patients whose breast is small, round and non-ptotic, especially when the nipple-areolar skin of the breast is preserved in the mastectomy.

Mutational Analysis of Key EGFR Pathway Genes in Chinese Breast Cancer Patients

  • Tong, Lin;Yang, Xue-Xi;Liu, Min-Feng;Yao, Guang-Yu;Dong, Jian-Yu;Ye, Chang-Sheng;Li, Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5599-5603
    • /
    • 2012
  • Background: The epidermal growth factor receptor (EGFR) is a potential therapeutic target for breast cancer treatment; however, its use does not lead to a marked clinical response. Studies of non-small cell lung cancer and colorectal cancer showed that mutations of genes in the PIK3CA/AKT and RAS/RAF/MEK pathways, two major signalling cascades downstream of EGFR, might predict resistance to EGFR-targeted agents. Therefore, we examined the frequencies of mutations in these key EGFR pathway genes in Chinese breast cancer patients. Methods: We used a high-throughput mass-spectrometric based cancer gene mutation profiling platform to detect 22 mutations of the PIK3CA, AKT1, BRAF, EGFR, HRAS, and KRAS genes in 120 Chinese women with breast cancer. Results: Thirteen mutations were detected in 12 (10%) of the samples, all of which were invasive ductal carcinomas (two stage I, six stage II, three stage III, and one stage IV). These included one mutation (0.83%) in the EGFR gene (rs121913445-rs121913432), three (2.50%) in the KRAS gene (rs121913530, rs112445441), and nine (7.50%) in the PIK3CA gene (rs121913273, rs104886003, and rs121913279). No mutations were found in the AKT1, BRAF, and HRAS genes. Six (27.27%) of the 22 genotyping assays called mutations in at least one sample and three (50%) of the six assays queried were found to be mutated more than once. Conclusions: Mutations in the EGFR pathway occurred in a small fraction of Chinese breast cancers. However, therapeutics targeting these potential predictive markers should be investigated in depth, especially in Oriental populations.

Effects of Age, Breast Density and Volume on Breast Cancer Diagnosis: A Retrospective Comparison of Sensitivity of Mammography and Ultrasonography in China's Rural Areas

  • Wang, Feng-Liang;Chen, Fei;Yin, Hong;Xu, Nan;Wu, Xiao-Xiang;Ma, Jing-Jing;Gao, Shen;Tang, Jin-Hai;Lu, Cheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2277-2282
    • /
    • 2013
  • Purpose: Mammography has been confirmed as the only effective mode to improve the prognosis of patients with breast cancer in Western developed countries, but might not be a good choice in other areas of the world. One of the major challenges in China is to determine an optimal imaging modality for breast cancer screening. This study was designed to clarify the sensitivity of ultrasonography compared with that of mammography in rural China. Methods: We retrospectively studied the sensitivity of mammography and ultrasonography based on 306 breast cancer patients detected by the program of "screening for cervical cancer and breast cancer" performed in Chinese rural areas between January 2009 and December 2011, and analyzed the effects of age, breast density and volume on the sensitivity. Results: Stratified analysis showed that the sensitivity of breast ultrasonography was significantly higher than that of mammography in premenopausal patients (81.4% vs. 61.1%, p=0.02), in women ${\leq}$ 55 years of age (82.2% vs. 63.4%, p<0.01), in the high breast density group (American College of Radiology [ACR] levels 3-4) (85.9% vs. 60.6%, p<0.01) and in the small breast volume group (${\leq}$ 400 ml) (87.1% vs. 66.7%, p<0.01). Age had a significant effect on sensitivity of mammography (breast density and volume-adjusted odds ratio, 6.39; 95% confidence interval, 2.8-14.4 in age group > 55 compared to age group ${\leq}$ 45), but not that of ultrasonography. Neither breast density nor volume had significant effect on sensitivity of mammography or ultrasonography. Conclusions: Ultrasonography is more sensitive than mammography in detecting breast cancer in women under 55 year-old Chinese, especially in those with high-density and relatively small breasts.

Feasibility Study for the Development of a Device for Detecting Pathological Tissues (병리학적 조직 진단장치 개발에 대한 타당성 분석 연구)

  • Ko, Chea-Ok;Park, Min-Young;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.421-424
    • /
    • 2005
  • X-ray is currently most effective method in detecting small malignant breast tumors but has the several problems due to suppressing breast, ionizing radiation and not detecting small cancer. In this paper, a new method is proposed by using dielectric characteristics of pathological tissues and time delay of backscattered response. We have developed a detection algorithm and verified it by numerical simulation and measurement for a prototype system. For a prototype system, we have fabricated experimental model(artificial breast with a cancer) and UWB(ultra-wideband) antenna. The results of the measurement simulation show an excellent detection capability of a cancer tissue. It is found that a good UWB antenna is a key element of such detection system. Further study is ongoing to develop a commercial system.

  • PDF

Cytologic Features of Infiltrating Lobular Carcinoma of the Breast in Ascitic Fluid - A Cese Report - (유방 소엽성 암종의 복수의 세포학적 소견 - 1예 보고 -)

  • Lee, Mi-Kyung;Lee, Kwang-Gil
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.1
    • /
    • pp.75-78
    • /
    • 1996
  • We experienced a case of infiltrating lobular carcinoma of the breast in the ascitic fluid. The patient was a 49 year-old woman who presented with a palable mass of 3 months duration in the left upper quadrant of the abdomen and abdominal distension. Five years ago, she had undergone left radical mastectomy with chemotherapy and radiotherapy for infiltrating lobular carcinoma of the breast. The ascitic fluid smears revealed singly scattered small round to elliptical cells, many of which were arranged in characteristic indian-file patterns consisting of 3 to 5 cells. The tumor cells had scanty cytoplasm, rare cytoplasmic vacuoles and marked chromatin clumping with small, but prominent nucleoli.

  • PDF

Identifying Differentially Expressed Genes and Screening Small Molecule Drugs for Lapatinib-resistance of Breast Cancer by a Bioinformatics Strategy

  • Zhuo, Wen-Lei;Zhang, Liang;Xie, Qi-Chao;Zhu, Bo;Chen, Zheng-Tang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10847-10853
    • /
    • 2015
  • Background: Lapatinib, a dual tyrosine kinase inhibitor that interrupts the epidermal growth factor receptor (EGFR) and HER2/neu pathways, has been indicated to have significant efficacy in treating HER2-positive breast cancer. However, acquired drug resistance has become a very serious clinical problem that hampers the use of this agent. In this study, we aimed to screen small molecule drugs that might reverse lapatinib-resistance of breast cancer by exploring differentially expressed genes (DEGs) via a bioinformatics method. Materials and Methods: We downloaded the gene expression profile of BT474-J4 (acquired lapatinib-resistant) and BT474 (lapatinib-sensitive) cell lines from the Gene Expression Omnibus (GEO) database and selected differentially expressed genes (DEGs) using dChip software. Then, gene ontology and pathway enrichment analyses were performed with the DAVID database. Finally, a connectivity map was utilized for predicting potential chemicals that reverse lapatinib-resistance. Results: A total of 1, 657 DEGs were obtained. These DEGs were enriched in 10 pathways, including cell cycling, regulation of actin cytoskeleton and focal adhesion associate examples. In addition, several small molecules were screened as the potential therapeutic agents capable of overcoming lapatinib-resistance. Conclusions: The results of our analysis provided a novel strategy for investigating the mechanism of lapatinib-resistance and identifying potential small molecule drugs for breast cancer treatment.