• Title/Summary/Keyword: slow-wave

Search Result 273, Processing Time 0.026 seconds

Incomplete Relationship between Dominant Power of Electrogastrography and Gastric Myoelectrical Activity in Patients with Functional Dyspepsia

  • Han, Sook-Young;Yoon, Sang-Hyub;Kim, Jin-Sung;Rhyu, Bong-Ha;Rhyu, Ki-Won
    • The Journal of Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.92-101
    • /
    • 2003
  • Background & Aims : The aim of this study was to investigate the change of dominant power with observation of gastric myoelectrical activity and its parameter linkage in electrogastrography. Methods : Electrogastrography was performed on a total of 123 subjects (113 patients with functional dyspepsia, 10 healthy controls) for 30 min in fasting state and 50 min in postprandial state. Average myoelectrical activity per frequency and accumulated electrical activity of 5 min duration in each bradygastria, normogastria, and tachygastria were measured at the moment of frequency switchover of slow wave. Assumed parameter linkages were also investigated among dominant frequency, % of normal regularity, and dominant power (or power ratio). Results : Average myoelectrical activity per frequency was highest in bradygastria (mean 1.10-1.47 Volt/s), next highest in normogastria (mean 0.50-0.82 Volt/s), and lowest in tachygastria (mean 0.44-0.47 Volt/s). Average accumulated myoelectrical activity was highest in normogastria (mean 114.90-126.29 Volt/ss), next highest in tachygastria (mean 71.02-90.00 Volt/ss), and lowest in bradygastria (mean 12.93-51.94 Volt/ss). Significance of parameter linkages were noted in dominant frequency (p< 0.01) and in % of normal regularity (p< 0.01), but not in dominant power in case of frequency shift from bradygastria to normogastria (p=0.376). Conclusion : Dominant power is not a parameter that reflects the gastric myoelectrical activity related with only gastric contraction. Bradygastric dominant power does not follow the inter-parameter linkage of electrogastrography for gastric motility assessment.

  • PDF

Effects of Single Treatment of Anti-Dementia Drugs on Sleep-Wake Patterns in Rats

  • Jung, Ji-Young;Roh, Moo-Taek;Ko, Kyung-Kyun;Jang, Hwan-Soo;Lee, Seong-Ryong;Ha, Jeoung-Hee;Jang, Il-Sung;Lee, Ho-Won;Lee, Maan-Gee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.4
    • /
    • pp.231-236
    • /
    • 2012
  • We studied the effects of acetylcholinesterase inhibitors, donepezil and galantamine, and an N-methyl-D-aspartate (NMDA) receptor blocker, memantine, on sleep-wake architecture in rats. Screw electrodes were chronically implanted into the frontal and parietal cortex for the electroencephalography (EEG). EEG was recorded with a bio-potential amplifier for 8 h from 09:30 to 17:30. Vibration was recorded to monitor animal activity with a vibration measuring device. Sleep-wake states such as wake (W), slow-wave sleep (S) and paradoxical or rapid eye movement sleep (P), were scored every 10 sec by an experimenter. We measured mean episode duration and number of episode to determine which factor sleep disturbance was attributed to. Donepezil and memantine showed a significant increase in total W duration and decreases in total S and P duration and delta activity. Memantine showed increases in sleep latency and motor activity. Changes of S and P duration in memantine were attributed from changes of mean episode duration. Galantamine had little effect on sleep architecture. From these results, it is showed that galantamine may be an anti-dementia drug that does not cause sleep disturbances and memantine may be a drug that causes severe sleep disturbance.

Methylene Blue-stained Interstitial Cells are Electrically Active in the Myenteric Board Freshly Prepared from the Murine Small Intestine

  • Lee, Kyu-Pil;Jeon, Ju-Hong;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.4
    • /
    • pp.193-198
    • /
    • 2006
  • Many gastrointestinal muscles show electrical oscillation, so-called 'slow wave', originated from interstitial cells of Cajal (ICCs). Thus, a technique to freshly isolate the cells is indispensable to explore the electrophysiological properties of the ICCs. To apply an enzyme solution on the serosal surface for cell isolation, the intestine was inverted and 0.02% trypsin solution and 0.04% collagenase solution were applied to serosal cavity. After the enzyme treatment, mucosal layer was removed and longitudinal muscle layer was gently separated from the rest of tissue. The thin layer was stretched in the recording chamber and mounted on an inverted microscope. Using ${\beta}-escine$, perforated whole cell patch clamp technique was used. Under a microscope, the tissue showed smooth muscle cells and interstitial cells around the myenteric plexus. Under voltage clamp condition, three types of membrane potential were recorded. One group of interstitial cells, which were positive to methylene blue and CD34, showed spontaneous outward current. These cells had bipolar shape and were considered as fibroblast-like cells because of their peculiar shape and arrangement. Another group, positive to c-kit and methylene blue, showed spontaneous inward current. These cells had more rounded shape and processes and were considered as ICCs. The third, positive to c-kit and had granules containing methylene blue, showed quiet membrane potentials under the voltage-clamp mode. These cells appeared to be resident macrophages. Therefore, in the freshly isolated thin tissue preparation, methylene blue could easily identify three types of cells rather than morphological properties. Using this method, we were able to study electrical properties of fibroblast and residential macrophage as well as myenteric ICCs.

Clinical Significance of Bifrontotemporal Decompressive Craniectomy in the Treatment of Severe Refractory Posttraumatic Brain Swelling (중증 외상성 뇌부종 환자에서 양측 전두-측두부 감압적 개두술의 의의)

  • Shin, Hyung Shik;Kim, Jin Yong;Kim, Tae Hong;Hwang, Yong Soon;Kim, Sang Jin;Park, Sang Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1179-1183
    • /
    • 2000
  • Objective : The treatment of malignant posttraumatic brain swelling remains a frustrating endeavor for neurosurgeon. Mortality and morbidity rates remain high depite advances in medical treatment of increased intracranial pressure. If conventional therapy fails in patients suffering from intracranial hypertension, there is only small number of second-tier option left including decompressive craniectomy. The role of decompressive craniectomy in posttraumatic brain swelling remains controversial. We assessed the efficacy and indications of decompressive craniectomy. Methods : The authors performed decompressive bifrontotemporal craniectomy in 22 patients with malignant posttraumatic brain swelling. Epidural pressure monotoring was performed in all patients. The clnical data and surgical outcomes were reviewed retrospectively. Result : The favorable outcome(GOS score 4-5) was 59%(13 of 22 patients), whereas the mortality rate was 32% (7 of 22 patients). Two patients(9%) remained in severely disabled state. Increased rate of favorable outcome was seen in the patients who had 8 or more of GCS score at admission and exhibited B wave in ICP monitoring and who showed steady state or slow deterioration in clinical course. Conclusion : If conservative therapy fails, decompressive bifrontotemporal craniectomy should be considered in the management of malignant posttraumatic brain swelling before irreversible ischemic brain damage occur.

  • PDF

A Study on the Characteristics of Microwave Transmission Lines Having Defected Ground Structures and Lumped Elements (결함접지구조와 집중소자를 지닌 초고주파 전송선로의 전기적 특성 연구)

  • Lim Jong-Sik;Bae Ju-Seok;Choi Kwan-Sun;Ahn Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.616-624
    • /
    • 2006
  • In this paper, the transfer characteristics of high frequency transmission line having defected ground structure (DGS) and lumped elements are described. When a DGS, which is a kind of periodic structure, is inserted into a transmission line, its equivalent inductance and capacitance elements are added to the characteristics of the standard transmission line. This generates resonance, 3dB cut-off frequency, low-pass, band rejection, and band pass characteristics, and causes a slow-wave and enlarged electrical length of the transmission line. In addition, if the DGS is combined by a lumped element such as resistor, capacitor, and inductor, the resonant and cut-off frequencies moves up or down and other changes occur in the transmission characteristics. The variation of the transmission characteristics is described with the qualitative prediction and measured data.

  • PDF

Development and Performance Test of TWTA Maintenance System for the Low Altitude Surveillance Radar (저고도 탐지레이더용 진행파관증폭기 정비시스템 개발 및 성능시험 연구)

  • Yoon, In-Chul;Yun, Seok-Jin;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.43-50
    • /
    • 2010
  • In this paper, the TWTA (Traveling Wave Tube Amplifier) maintenance system for the low altitude surveillance Radar was developed using the embedded Linux system, and its superiority was demonstrated through the performance test. Nowadays, the necessity of maintenance system and reliability testing on military equipments has been increasing steadily. In addition, nonlinear characteristics of the maintenance system for the low altitude surveillance Radar are more likely to have serious problems as well as to slow down durability. Therefore, after analyzing characteristics of RF input-output signal and TWTA, we designed interface circuits between the TWTA equipment and the embedded Linux system. The Linux kernel on the system was optimized to improve the efficiency and reliability. And our new TWTA maintenance system was evaluated in the real field. As a result, the proposed system was contented with desired specifications, and demonstrated military's fighting capabilities. Therefore, our novel system will advance military maintenance technology and will help to develop similar equipments.

Real-time surface acoustic wave reader platform implementation in the frequency domain sampling method using a Cortex-A9 (Cortex-A9을 이용한 주파수 영역 샘플링 방식의 실시간 표면 탄성파 리더 플랫폼 구현)

  • Yoon, Sang-hun;kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.343-345
    • /
    • 2015
  • Currently, SAW Device has been used as a frequency filter using the property of passing only a desired frequency with a narrow bandwidth. However, the areas of activity in various fields since the permanent advantages can be widened by using a non-powered. These sensor tags using SAW Device has been done, but a lot of research, the development of the state still insufficient for Reader Platform. How to read the value of the ID Tag Using SAW Device has a time domain sampling (TDS) method and a frequency domain sampling (FDS) method. The purpose of the paper, we use the FDS method that requires high-speed processing with a relatively slow sampling rate does not require high-speed sampling. Reader Platform was the way to detect ID through PC as FDS way, but It is based on the Cortex-A9 processor and it works a low price, compact and real-time Reader Platform.

  • PDF

Obstructive sleep apnea syndrome in children: Epidemiology, pathophysiology, diagnosis and sequelae

  • Chang, Sun-Jung;Chae, Kyu-Young
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.10
    • /
    • pp.863-871
    • /
    • 2010
  • The prevalence of pediatric obstructive sleep apnea syndrome (OSAS) is approximately 3% in children. Adenotonsillar hypertrophy is the most common cause of OSAS in children, and obesity, hypotonic neuromuscular diseases, and craniofacial anomalies are other major risk factors. Snoring is the most common presenting complaint in children with OSAS, but the clinical presentation varies according to age. Agitated sleep with frequent postural changes, excessive sweating, or abnormal sleep positions such as hyperextension of neck or abnormal prone position may suggest a sleep-disordered breathing. Night terror, sleepwalking, and enuresis are frequently associated, during slow-wave sleep, with sleep-disordered breathing. Excessive daytime sleepiness becomes apparent in older children, whereas hyperactivity or inattention is usually predominant in younger children. Morning headache and poor appetite may also be present. As the cortical arousal threshold is higher in children, arousals are not easily developed and their sleep architectures are usually more conserved than those of adults. Untreated OSAS in children may result in various problems such as cognitive deficits, attention deficit/hyperactivity disorder, poor academic achievement, and emotional instability. Mild pulmonary hypertension is not uncommon. Rarely, cardiovascular complications such as cor pulmonale, heart failure, and systemic hypertension may develop in untreated cases. Failure to thrive and delayed development are serious problems in younger children with OSAS. Diagnosis of pediatric OSAS should be based on snoring, relevant history of sleep disruption, findings of any narrow or collapsible portions of upper airway, and confirmed by polysomnography. Early diagnosis of pediatric OSAS is critical to prevent complications with appropriate interventions.

Characterization of thermally driven polysilicon micro actuator (폴리실리콘 마이크로 액츄에이터의 열구동 특성분석)

  • Lee, Chang-Seung;Lee, Jae-Youl;Chung, Hoi-Hwan;Lee, Jong-Hyun;Yoo, Hyung-Joun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.2004-2006
    • /
    • 1996
  • A thermally driven polysilicon micro actuator has been fabricated using surface micromachining techniques. It consists of P-doped polysilicon as a structural layer and TEOS (tetracthylorthosilicate) as a sacrificial layer. The polysilicon was annealed for the relaxation of residual stress which is the main cause to its deformation such as bending and buckling. And the newly developed HF VPE (vapor phase etching) process was also used as an effective release method for the elimination of sacrificial TEOS layer. The thickneas of polysilicon is $2{\mu}m$ and the lengths of active and passive polysilicon cantilevers are $500{\mu}m$ and $260{\mu}m$, respectively. The actuation is incurred by die thermal expansion due to the current flow in the active polysilicon cantilever, which motion is amplified by lever mechanism. The moving distance of polysilicon micro actuator was experimentally conformed as large as $21{\mu}m$ at the input voltage level of 10V and 50Hz square wave. The actuating characteristics are investigated by simulating the phenomena of heat transfer and thermal expansion in the polysilicon layer. The displacement of actuator is analyzed to be proportional to the square of input voltage. These micro actuator technology can be utilized for the fabrication of MEMS (microelectromechanical system) such as micro relay, which requires large displacement or contact force but relatively slow response.

  • PDF

The Changes of Sleep-Wake Cycle from Jet-Lag by Age (연령에 따른 비행시차 후의 수면-각성주기 변화)

  • Kim, Leen;Lee, Seung-Hwan;Suh, Kwang-Yoon
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.18-31
    • /
    • 1996
  • Jet-lag can be defined as the cumulative physiological and psychological effects of rapid air travel across multiple time zones. Many reports have suggested that age-related changes in sleep reflect fundamental changes in the circadian system and in significant declines in slow wave sleep. Jet lag is a dramatic situation in which the changes of the phase of circadian process and homeostatic process of sleep occur. Thus the authors evaluatead the changes of sleep-wake cycle from jet lag by age. Thirty-eight healthy travellers were studied for 3 days before and 7 days after jet-flights across seven to ten time zone. They were aged 19-70, They trareled eastbound, Seoul to North America (USA, Canada). Sleep onset time, wake-up time, sleep latency, awakening frequency on night sleep, awakening duration on night sleep, sleepiness at wake-up and nap length were evaluated. Our results suggest that by the 7 to 10 time zone shift, the old age group was significantly influenced in sleep-wake cycles. The date on which subjective physical condition was recovered was $6.23{\pm}83$ day after arrivals for old age group, while for young and middle age group, $4.46{\pm}1.50$ day and $4.83{\pm}1.52$ day, respectively. In old age group, sleep onset time was later than baselines and could not recover untill 7th day. But in other groups, the recovery was within 5th day. Nap dura fion was longer in old age group through jet lag than younger age group. In other parameters, there was no definite difference among three age groups. Our results suggested that the old age was significantly influenced by the disharmony between internal body clock and sleep-wake cycle needed at the travel site. Thus we proved that recovery ability from jet lag was age-dependent as well as travelling direction-dependent. To demonstrate more definite evidence, EEG monitoring and staging of sleep were funthun encouraged.

  • PDF