• Title/Summary/Keyword: slot-line

Search Result 257, Processing Time 0.025 seconds

Novel Coupling Condition between Optical Fiber and Microstrip Antenna in Photonic Antenna (Photonic 안테나에서 광섬유와 마이크로스트립 안테나사이의 새로운 결합조건)

  • Ho Kwang-Chun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.4 s.346
    • /
    • pp.31-37
    • /
    • 2006
  • Strongly motivated by the need for significant reduction in the optics-to-antenna interface circuitry used in a Photonically controlled array, it has proposed the design development of a novel 'true photonic antenna' consisted of optical fiber and micro-strip antenna. To clarify the design capability of the geometry, modal transmission-line theory including the discontinuity property between circular i,nd planar guiding structures is defined, md the optical power coupling of a slot-coupled microstrip antenna directly fed from an optical fiber using photoconductive effect is evaluated numerically. The numerical results reveal that the maximum power transfer between the two different guiding structures occurs at a new point in which the guiding powers of two rigorous modes are equally partitioned.

Design of Microstrip Patch Array Antenna for ISM Band (ISM대역용 마이크로스트립 패치 배열 안테나 설계)

  • 이현진;임영석
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.119-124
    • /
    • 2004
  • In this paper, we are designed and fabricated circular polarization microstrip patch antenna of 5[GH]z bandwidth for the wireless LAN and the ISM. We are proposed new structure that removed the section which intersected at a right angle and were composed to four separated slots. The antenna of proposed structure could solve parasitic elements from intersected in a right angle and weak coupling efficiency from asymmetry between feed line and a slot. The proposed cross slots antenna is easily impedance matching and increased impedance bandwidth. Also this is increased efficiency and a bandwidth of antenna and reduce back lobe of radiation pattern. We designed 2${\times}$2 array antenna of 5[GHz] band. It took impedance bandwidth 280[MHz](VSWR < 1.5) and gam 12.5[dBi]

Performance of a Planar Leaky-Wave Slit Antenna for Different Values of Substrate Thickness

  • Hussain, Niamat;Kedze, Kam Eucharist;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.202-207
    • /
    • 2017
  • This paper presents the performance of a planar, low-profile, and wide-gain-bandwidth leaky-wave slit antenna in different thickness values of high-permittivity gallium arsenide substrates at terahertz frequencies. The proposed antenna designs consisted of a periodic array of $5{\times}5$ metallic square patches and a planar feeding structure. The patch array was printed on the top side of the substrate, and the feeding structure, which is an open-ended leaky-wave slot line, was etched on the bottom side of the substrate. The antenna performed as a Fabry-Perot cavity antenna at high thickness levels ($H=160{\mu}m$ and $H=80{\mu}m$), thus exhibiting high gain but a narrow gain bandwidth. At low thickness levels ($H=40{\mu}m$ and $H=20{\mu}m$), it performed as a metasurface antenna and showed wide-gain-bandwidth characteristics with a low gain value. Aside from the advantage of achieving useful characteristics for different antennas by just changing the substrate thickness, the proposed antenna design exhibited a low profile, easy integration into circuit boards, and excellent low-cost mass production suitability.

Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

Stator Insulation Quality Assessment for High Voltage Motors Based on Probability Distributions

  • Kim, Hee-Dong;Kim, Chung-Hyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.571-575
    • /
    • 2008
  • Stator insulation quality assessment for high voltage motors is a major issue for the reliable maintenance of industrial and power plants. To assess the condition of stator insulation, nondestructive tests were performed on the sixty coil groups of twelve motors. After completing the nondestructive tests, the AC voltage applied to the stator winding was gradually increased until insulation failure in order to obtain the breakdown voltage. The stator winding of each motor was classified into five coil groups; one group with healthy insulation and four groups with four different types of artificial defects. To analyze the breakdown voltage statistically, Weibull distribution was employed for the tests on the fifty coil groups of ten motors. The 50th percentile values of the measured breakdown voltages based on the statistical data of the five coil groups of ten motors were 26.1kV, 25.0kV, 24.4kV, 26.7kV and 30.5kV, respectively. Almost all of the failures were located in the line-end coil at the exit of the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of dissipation factor and ac current. It is shown that the condition of the motor insulation can be determined from the relationship between the probability of failure and the type of defect.

Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings (6.6 kV급 고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kim, Byong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

On-line Parameter Estimation of IPMSM Drive using Neural Network (신경회로망을 이용한 IPMSM 드라이브의 온라인 파라미터 추정)

  • Park, Ki-Tae;Choi, Jung-Sik;Ko, Jae-Sub;Lee, Jung-Ho;Kim, Jong-Kwan;Park, Byung-Sang;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.761-762
    • /
    • 2006
  • A number of techniques have been developed for estimation of speed or position in motor drives. The accuracy of these techniques is affected by the variation of motor parameters such as the stator resistance, stator inductance or torque constant. This paper is proposed a neural network based estimator for torque and stator resistance in IPMSM Drives. The neural weights are initially chosen randomly and a model reference algorithm adjusts those weights to give the optimum estimations. The neural network estimator is able to track the varying parameters quite accurately at different speeds with consistent performance. The neural network parameter estimator has been applied to slot and flux linkage torque ripple minimization of the IPMSM. The validity of the proposed parameter estimator is confirmed by the operating characteristics controlled by neural networks control.

  • PDF

Analysis on the Power Spectrum of Direct Sequence-Time Hopping UltraWideBand System (DS-TH UWB 시스템의 전력 스펙트럼 분석)

  • Kim Young-Chul;Lee Jeong-suk;Kang Duk-Keun
    • Journal of Digital Contents Society
    • /
    • v.5 no.3
    • /
    • pp.219-224
    • /
    • 2004
  • In This paper, we have analyzed the power spectrum of DS-TH Ulhawideband (Direct Sequence-Time Hopping UWB) system which used pseudo-noise (PN) code. The DS-TH UWB system proposed in this paper multiplies the information signal with PN code to construct pulse train with random pattern and then the chips in pulse train are bundled into several groups to map to the particular value. The (+)/(-) pulse is tented in the time slot of frame by comparing a particular value with timing information that was stored in the lookup table. Thus, the energy spark (Comb Line) which is generated certainly in convantional system can be suppressed efficiently by PN code. And we knew that the proposed DS-TH UWB System even could have very smoothing power spectrum ctaracteristic without applying high speed Time-Hopping code.

  • PDF

A Transitional Behavior of a Premixed Flame and a Triple Flame in a Lifted Flame(II) (부상화염에서 예혼합화염과 삼지화염의 천이적 거동(II))

  • Jang Jun Young;Kim Tae Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.376-383
    • /
    • 2005
  • In the paper we investigate characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. In previous study, we showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame. A gas-chromatograph is used to measure concentration field, a smoke-wire system is used to measure streak line, and a PIV system is used to measure velocity field in lifted flame. In the visualization experiment of smoke wire, the flow divergence and redirection reappeared in premixed flame as well as triple flame. Thus we cannot express the flame front of lifted flame has a behavior of triple flame with only flow divergence and redirection. In PIV measurement, flow velocity for those three flames has minimum value at the tip of flame front. To differentiate triple flame and premixed flame, $\Phi$ value of partially premixed fraction is employed. The partially premixed fraction $\Phi$ was constant in premixed flame. In critical flame small gradient appears over the whole regime. In triple flame, typical diffusion flame shape is obtained as parabolic distribution type due to diffusion flame trailing.

Biological Treatment of OCC Flake in Fine Screen Rejects for Recovery of Fibrous Materials (생물학적 처리에 의한 OCC 스크린 리젝트 내 미해리분의 재활용)

  • Sung Yong Joo;Ryu Jeong-Yong;Song Bong Keun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.1 s.109
    • /
    • pp.17-24
    • /
    • 2005
  • The increase of using low grade ace, the unsorted mixed grade, as fibrous raw materials for the packaging paper results in the increment of fine screen reject owing to the strong tendency to reduce the slot width. Since the most of screen reject consists of undispersed fiber flake, the suitable treatment of the flake could increase the yield of ace recycling and decrease the amount of solid waste. In this work, the novel method combined the mild mechanical treatment by using Tumbling pulper with the biological treatment was developed and applied to the wet strength flake and the fine screen tail line reject originated from a packaging paper mill. The results showed the new method could provide much better efficiency for the disintegration of undispersed flake and for the recovery of fiber from the rejects. The application of the laboratory scaled-Pack pulper showed the possible separation technique for mill application by fractioning effectively the fiber from the treated solid waste.