• 제목/요약/키워드: slip tendency

검색결과 39건 처리시간 0.022초

건축물 바닥재의 마모에 따른 미끄럼성능 변동에 관한 연구 (A Study on the Change of Slipperiness of Building Floor-coverings by Friction Wear)

  • 신윤호;최수경
    • 한국건축시공학회지
    • /
    • 제5권1호
    • /
    • pp.53-61
    • /
    • 2005
  • The purpose of this study presents useful data on the choice or development of floor covering from slip viewpoint by examining closely the impact of the changes in sliding experiments due to the wear of floor covering by walk. The result of wear practical test per ten thousand walks enforces some kind of popular floor covering and measure of coefficient of slip resistance as follows: (1) When surface of floor covering is in the state of wet, the degree of wear doesn't affect greatly in slip. (2) When surface of floor covering is in dry and clean state, most floor coverings have the tendency to lower the coefficient of slip resistance with the amount of walk on it. (3) Change in the tendency of slip resistance by wear appeared mainly due to the differences in the state of floor covering and organic floor covering appeared to have great reduction of coefficient of slip resistance than the inorganic ones. (4) According to the result of investigation on changes in tendency of coefficient of slip resistance due to the increase in the number of walk and if two hundred thousand walks were done, regardless of surface shape or kind of site, etc, the safety of floor covering, in slip viewpoint, greatly reduces.

미끄럼 측정치로서의 뒤로미끄러짐 (Backward Slip as a Measure of Floor Slipperiness)

  • Myung, Rohae
    • 대한인간공학회지
    • /
    • 제20권2호
    • /
    • pp.47-57
    • /
    • 2001
  • To simulate an actual slip to measure floor slipperiness, slip resistance testers simulate slip in only forward direction because forward slip in the landing phase was found to be the most important factor for loss of balance. Backward slip in the take off phase was possible but was excluded in the friction test protocol because it was not dangerous. However, backward slip was tested in the friction test protocol without any theoretical background of the significance in generating dangerous slips and falls and was proven to be as good as forward slip in measuring floor slipperiness. Therefore, this study was designed to investigate the significance of backward slip in generating dangerous slips and falls with different combinations of floor and shoe sole. The results showed different tendency of backward slip in take off phase being significant in generating dangerous slips and falls because backward slip in the takeoff phase affected gait pattern disturbances seriously. resulted in dangerous falls. Fast toe velocity increased the severity of backward slip and confirmed the significance of backward slip in generating dangerous slips and falls. As a result, this study recommends the utilization of backward slip in the measurement of floor slipperiness.

  • PDF

현생 응력하에서 단층 마찰계수에 따른 임곡단층의 거동 가능성 해석 (Friction-dependent Slip Behavior of Imgok Fault under the Present-day Stress Field)

  • 나현우;장찬동;장천중
    • 지질공학
    • /
    • 제23권3호
    • /
    • pp.217-225
    • /
    • 2013
  • 강릉지역의 NNE-SSW 주향을 갖는 선형구조(임곡단층)를 대상으로, ASTER 영상과 항공사진을 이용한 구조 영상 분석과 야외지질조사를 통해 단층의 기하 및 운동학적 특성을 관찰하고 단층의 지질역학적 특성에 대한 분석을 시도하였다. 현생 응력장 하에서 임곡단층의 운동 가능성 여부를 파악하기 위해 이용된 주변 지진자료는 이 지역의 현생 최대응력방향이 약 N$70^{\circ}$E이며 주향이동과 역단층 운동에 유리한 응력상태임을 보여준다. 현생 응력장 하에서 임곡단층이 운동하기에는 최적의 방향에서 오차 범위 밖의 주향을 보여 전단 성향이 낮은 것으로 분석되었다. 그러나 단층의 역학적 특성을 나타내는 마찰계수(${\mu}$)가 상당히 낮을 경우(예를 들어 0.25 이하) 현생 응력장 하에서도 운동 가능성이 있는 것으로 파악된다.

공작기계 이송계의 Stick-Slip 특성에 관한 연구 (A study on the Stick-slip Characteristic of Machine Tool Feeding System.)

  • 박종권;이후상
    • 한국기계연구소 소보
    • /
    • 통권18호
    • /
    • pp.29-35
    • /
    • 1988
  • When low sliding velocities in the boundary lubrication range are operating, irregular movements frequently occur which are a result of the stick-slip phenomenon. Such slide motions are undesirable in precision machine tools, particularly with feed back systems used in numerical and adaptive control machine tools. Accordingly, this paper reports analytical and experimental studies in the stick-slip characteristic of machine tool feeding system. The main conclusions of this study are as follows; The tendency towards stick-slip effects may be reduced by; 1). Reducing the drop in friction coefficient in the Stribeck curve(on the rising part of the friction characteristic at higher sliding speeds, the system is stable all the time) 2). Reducing the transition velocity by the use of a higher viscosity lubricating oil. 3). Increasing the stiffness(Damping)and reducing normal load(Sliding mass) Therefore, the Critical velocity is decided from the above conclusions and in designing of machine tool, feed rates(sliding velocity)must be design the more than critical velocity.

  • PDF

슬립 캐스팅을 이용한 통기성 세라믹형의 쾌속 제작 (Rapid Tooling of Porous Ceramic Mold Using Slip Casting)

  • 정성일;정두수;임용관;정해도;조규갑
    • 한국정밀공학회지
    • /
    • 제16권5호통권98호
    • /
    • pp.98-103
    • /
    • 1999
  • The application field of porous mold is more and more expended. A mixture of alumina and cast iron is used for making porous mold using slip and vacuum casting method in this study. Slip casting is a process that slurry is poured into silicon rubber mold, dried in vacuum oven, debinded and sintered in furnace, In this procedure, slurry is composed of powder, binder, dispersion agent, and water. Vacuum casting is a technique for removing air bubbles existed in the slurry under vacuum condition. Since ceramics has a tendency of over-shrinkage after sintering, cast iron is used to compensate dimensional change. The results shows that sintering temperature has a great effect on characteristics of alumina-cast iron composite sintered parts. Finally ceramic-metal composite sintered mold can be used for aluminum alloy casting of shoe mold using this process.

  • PDF

고온하에서 지르칼로이-4 튜브의 프레팅 마멸 특성 (The Fretting Wear Characteristics of Zircaloy-4 Tube at High Temperature)

  • 백승철;김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.89-95
    • /
    • 2001
  • The fretting wear characteristics of Zircaloy-4 tube at room and high temperature were Investigated experimentally. In this study, the number of cycles, slip amplitude and temperature were selected as main factors of fretting wear. The results of this research showed that the wear volume Increased with the Increase of slip amplitudes and the number of cycles but decreased with temperature and the coefficient of friction were observed different tendency between room and high temperature. According to SEM(EDS) only gross slip were observed on the surface of both specimens and compacted oxide were on worn surfaces. XRO patterns showed that the crystallization of ZrO$_2$ were observed on the worn surface at high temperature. The fretting wear were Investigated due to oxidation and accumulation of plastic flow.

  • PDF

임플랜트와 지대주 간 내측연결 시스템에서 Friction Fit와 Slip Fit에 따른 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis According to Friction Fit or Slip Fit of Internal Connection System between Implant and Abutment)

  • 장두익;정승미;정재헌
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.113-132
    • /
    • 2005
  • The purpose of this study was to assess the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to a friction-fit joint (Astra; Model 1) or slip- fit joint (Frialit-2; Model 2) in the internal connection system under vertical and inclined loading using finite element analysis. In conclusion, in the internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to the abutment connection form had difference among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the abutment post. The magnitude of the stress distributed in the supporting bone, the implant fixture, the abutment and the abutment screw was higher in the friction-fit joint than in the slip-fit joint. But it is considered that the further study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

경계면 슬립이 적용되는 Plate-Fin Heat Sink 의 최적형상 설계 (Optimal Design of a Plate-Fin Heat Sink with Slip Flow)

  • 박부성;박현진;김보흥
    • 한국정밀공학회지
    • /
    • 제32권2호
    • /
    • pp.219-227
    • /
    • 2015
  • A dehumidifier using a thermoelement has many advantages compare to a dehumidifier using compressor systems. However, it is crucial to optimize the performance of heat sink for improving heat dissipation problem on the heat generation part. In this study, we utilized computational fluid dynamics software to compare Nusselt number, temperature and system efficiency based on fin thickness, flow gap between fin and fin length. Moreover, slip flow on the boundary layer was applied for the further analysis. Our objective in this study is to suggest an optimal fin shape to improve heat transfer with the tendency of performance factor depending on change of the shapes. Our results on the optimization of fin shape and analysis of slip flow will be utilized to enhance the heat transfer in the heat sink which is important in the design of dehumidifier using a thermoelement.

부식 수준 및 균열폭에 따른 부식된 철근과 콘크리트 계면의 부착-미끄러짐 거동 (Effect of Corrosion Level and Crack Width on the Bond-Slip Behavior at the Interface between Concrete and Corroded Steel Rebar )

  • 조상현;기성훈;이정재;이창계
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.54-63
    • /
    • 2023
  • 본 논문에서는 부식된 철근과 콘크리트 계면의 부착강도-슬립거동에 있어 부식수준 및 균열폭의 영향에 대한 연구를 수행하였다. 기존의 연구는 주로 부식수준에 따른 부착강도 저하에 초점을 맞추고 있으나 부식에 의한 콘크리트 표면 균열폭에 따른 부착강도 저하에 관한 연구는 매우 적다. 따라서 본 연구에서는 부식된 철근과 콘크리트 접합부의 부착강도, 슬립 거동 및 철근의 질량손실 등을 평가하고 균열폭 대비 접합성능을 확인하기 인발시험을 실시하였다. 그 결과로 표면 균열폭에 따른 접착강도 저하의 경향성이 부식수준에 따른 경향성보다 균등하게 나타났다. 따라서 부식수준에 비해 콘크리트 표면 균열 발생 여부가 부착강도-슬립거동 관계의 성능저하를 판단하기에 적합한 것으로 판단된다.

확장된 slip-weakening 모델의 응력 강하량과 에너지 수지 특성 및 스케일링 관계 (Characteristics of Stress Drop and Energy Budget from Extended Slip-Weakening Model and Scaling Relationships)

  • 최항;윤병익
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.253-266
    • /
    • 2020
  • The extended slip-weakening model was investigated by using a compiled set of source-spectrum-related parameters, i.e. seismic moment Mo, S-wave velocity Vs, corner-frequency fc, and source-controlled high-cut frequency fmax, for 113 shallow crustal earthquakes (focal depth less than 25 km, MW 3.0~7.5) that occurred in Japan from 1987 to 2016. The investigation was focused on the characteristics of stress drop, radiation energy-to-seismic moment ratio, radiation efficiency, and fracture energy release rate, Gc. The scaling relationships of those source parameters were also investigated and compared with those in previous studies, which were based on generally used singular models with the dimensionless numbers corresponding to fc given by Brune and Madariaga. The results showed that the stress drop from the singular model with Madariaga's dimensionless number was equivalent to the breakdown stress drop, as well as Brune's effective stress, rather than to static stress drop as has been usually assumed. The scale dependence of stress drop showed a different tendency in accordance with the size category of the earthquakes, which may be divided into small-moderate earthquakes and moderate-large earthquakes by comparing to Mo = 1017~1018 Nm. The scale dependence was quite similar to that shown by Kanamori and Rivera. The scale dependence was not because of a poor dynamic range of recorded signals or missing data as asserted by Ide and Beroza, but rather it was because of the scale dependent Vr-induced local similarity of spectrum as shown in a previous study by the authors. The energy release rate Gc with respect to breakdown distance Dc from the extended slip-weakening model coincided with that given by Ellsworth and Beroza in a study on the rupture nucleation phase; and the empirical relationship given by Abercrombie and Rice can represent the results from the extended slip-weakening model, the results from laboratory stick-slip experiments by Ohnaka, and the results given by Ellsworth and Beroza simultaneously. Also the energy flux into the breakdown zone was well correlated with the breakdown stress drop, ${\tilde{e}}$ and peak slip velocity of the fault faces. Consequently, the investigation results indicate the appropriateness of the extended slip-weakening model.