• Title/Summary/Keyword: slab structure

Search Result 593, Processing Time 0.027 seconds

A Study on Factors Influencing the Shear Strength of Shear Connectors (전단연결재 강도산정 영향인자에 대한 연구)

  • 여진호;임남형;강영종
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1091-1096
    • /
    • 2001
  • Generally, in a steel girder and the concrete slab act as a composite structure, the connectors must have adequate strength and stiffness. If there are no horizontal or vertical separations at the interface, the connectors are described as rigid, and complete interaction can be said to exist under these idealized circumstances. In previous study, it was considered that the strength of stud is affected by the stud diameter, height of stud and compressive strength of concrete. The differences between previous study and this study are variables, which are shank diameter of shear connector, the spacing of shear connector, the size of specimen and the row of shear connector. So this paper, as a study on the strength of shear connector with the spacing of shear connector, size of specimen (block-out size), row of shear connector and shank diameter of shear connector resulted from the push-out specimen are conducted with ABAQUS program. It is to investigate the effects of characteristics of these factors. The load-slip relations obtained from the experiments are compared with those of analyses. From these results, the trends of stress are stress estimated and compared with push-out test.

  • PDF

Nonlinear Dynamic Response of Well-Slab Apartment Building Considering The Behavior of Coupling Elements (벽식 아파트 구조에서 연결부재의 거동특성을 고려한 비선형 동적 응답)

  • 김기현;장극관;서대원;천영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.437-442
    • /
    • 2002
  • The purpose of this study is to investigate nonlinear behavior and estimate ultimate resistance of the wall structure against seismic loading. Experimental data for RC coupling elements are used for specifying the strength deterioration and stiffness degradation factor of hysteretic model. Modified coupling element models are used in the push over analysis and time history analysis. In the time history analysis, three earthquake waves are used in the analysis and their peak ground accelerations are changed to be 0.2g. The conclusions of this study are as follows : (1) In the push over analysis, yielding of coupling elements occurred at lower story with small story drift ratio as 0.3%. (2) In the time history analysis, the story drift ratio is sufficient for the requirement of Korean Code, But coupling elements at most stories of the buildings occurred yielding. i. e. the earthquake resistant capacity of shear wall structures is not sufficient at 0.2g.

  • PDF

A Study on the Model Development for Production of Interior Drawings and estimation of Quantities (실내도면 작성과 물량산출을 위한 모델 개발에 관한 연구)

  • 정례화;이승우;추승연
    • Korean Institute of Interior Design Journal
    • /
    • no.19
    • /
    • pp.30-37
    • /
    • 1999
  • This study presents a methods on the construction of integrated system for the purpose of automation of design plans, calculation of quantity of materials and estimation by abstracting information on building materials which is produced on the course of three dimension modeling by using computer. Therefore, an object oriented methodology is introduced to compose design informations in three dimension, space for unifying building informations, and expressing properties of building factors and materials, and to construct a database for computers to recognize architecture informations. An object indicates a conceptual individual existing in real world or existence of individual and necessity in composing a building could be called as objects such as column, wall, beam, slab, door and window and these contain materiality and immateriality. It is systemized to which properties of these building's objects are installed by the user of computer and by API(Application Programming Interface), chosen informations automatically converse to each unit work such as design plan structure plan, calculation of amount of materials, etc.

  • PDF

Density functional study of silanization of the silica surface (실리카 표면의 실란화에 대한 범밀도 함수 계산)

  • Kang, Jee-Won;Lee, Yoon-Sup
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.521-526
    • /
    • 2007
  • Density functional calculations have been performed for the reactions of perfluoroalkylsilane and alkylsilane with silica surfaces. The (100) and (111) surfaces of ${\beta}-cristobalite$ are used as two possible models of the hydroxylated amorphous silica surface. This is the crystalline phase of silica with density and refractive index closest to those of amorphous silica. Moreover, two ${\beta}-cristobalite$ surfaces have the two types of silanol groups, namely the single silanols and the geminal silanols. We investigate the possible adsorption structure and formation energy of perfluoroalkylsilane and alkylsilane molecules with two type of silanol groups. The results will be compared with cluster and slab model.

  • PDF

Evaluation for the Test Installation of Slab Track by Using Precast Concrete Panels (Precast Concrete Panel을 사용한 슬라브궤도 시험시공에 대한 평가)

  • Kim Soon-Cheol;Kong Sun-Yong;Kang Jeong-Ok;Lee Jong-Min;Han Kwang-Seob
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1071-1077
    • /
    • 2004
  • This paper is presenting the performance evaluation on the installed concrete panels. As a result of the evaluation, the resistance to track displacement of temporary support structure was improved and it resulted in the improvement of work stability during installation. And, by the application of new technology and the saving of concrete consumption, both workability and cost were improved and, therefore, the shorter project period and cost saving can be expected. Furthermore, as a result of noise & vibration measurement at site, it has shown good effects of anti-noise and anti-vibration. In conclusion, this process was proved as very effective for track improvement.

  • PDF

Fabrication of Nano-photonic Crystals with Lattice Constant of 460-nm by Inductively-coupled Plasma Etching Process (유도결합형 플라즈마 식각공정을 통해 제작된 460 nm 격자를 갖는 나노 광결정 특성)

  • Choi, Jae-Ho;Kim, Keun-Joo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.2 s.15
    • /
    • pp.1-5
    • /
    • 2006
  • The GaN thin film on the 8 periods InGaN/GaN multi-quantum well structure was grown on the sapphire substrate using metal-organic chemical vapor deposition. The nano-scaled triangular-lattice holes with the diameter of 150 nm were patterned on a polymethylmethacrylate blocking film using an electron beam nano-lithography system. The thin slab and two-dimensional photonic crystals with the thickness of 28 nm were fabricated on the GaN layer for the blue light diffraction sources. The photonic crystal with the lattice parameter of 460 nm enhances spectral intensity of photoluminescence indicating that the photonic crystals provides the source of nano-diffraction for the blue light of the 450-nm wavelength.

  • PDF

A Study on the Development of the Wheel Tracking Test and Evaluation Method on Blind Type of Waterproofing Layer (비노출 방수층의 윤하중 시험 및 평가방법 개발에 관한 실험적 연구)

  • Song Je-Young;Eom Deok-Jun;Kwak Kyu-Sung;Oh Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.67-72
    • /
    • 2006
  • There are a lot of problem about waterproofing membrane coating for concrete deck of bridge and waterproofing sheets for concrete of deck of bridge because it couldn't confirm waterproofing's defeat after construction. These problems make a waterproofing material damage and condrete deck of bridge damage. So It needs a lot of money for repair work and reinforcement work. Therefor the structure slab of using waterproofing material protect invasion of water. Also, Concrete deck of bridge need a endurance permeability for the reduction repair payment. In this study, An experimental study on the quality standardization test method waterproofing layer on working of live load.

Study on Structural-Acoustic Characteristics for Improving Soundproof Qualities to Changeable Wall in Apartment Buildings (공동주택의 건식 가변벽체 접합부 차음성능 향상을 위한 구조음장 특성 해석기법에 관한 연구)

  • Kim, Hwa-Il
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1291-1297
    • /
    • 2009
  • The purpose of this study was to establish structural bone noise analysing method for apartments building floor with Structural-Acoustic coupling analysis. Nowadays, noise through floor is recognized as important problem with the consequence that noise isolation technique is studied in the various fields of industry. From among noise factors, resonance sound is main reason for floor's solid noise. therefore, In this study, evaluation method for composite material slab is established and that a case study is suggested with it.

Train Vibration Serviceability Evaluation Near Railroad Areas Using Mobile-phone Application (휴대폰 앱을 통한 철도인접지역의 열차진동 사용성평가)

  • Jung, Young-Seok;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.109-116
    • /
    • 2016
  • Recently, with development of city traffic network planning, there are various effects with living space from vibration of railway. But, study which about effect from vertical vibration in floor slab in nearing structure is lack in nowadays. This thesis have analysed result from acceleration response per distance as well as proceed with serviceability evaluation and extracted natural frequency from measuring vibration of railway using mobile phone application which is oriented for building which have distances about 5m to 22m from railway.

The Application Of F.C.M(Free Cantilever Method) Case Study Of The Railway Bridge (철도교량 F.C.M(Free Cantilever Method) 공법 시공사례 연구)

  • Kwon, Soon-Seob;Kim, Kyong-Yeon;Choi, Dong-Kee;Jeong, In-Choul;Shin, Sang-Chul
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.562-567
    • /
    • 2005
  • F.C.M applied from Jin Jung Li to Yang Su Li(660m) in Puk Han River Bridge(1,414m) construction part is a construction method on the double-track construction which is the third section part of work, called Chung Ang Railroad Line(Deok-So${\sim}$Won-Ju). This method is the beginning application on Railroad Bridge. After completing upper slab structure, there are several following works such as setting up ballast, sleepers and laying long rails. So it is important to consider the properties of Railroad Bridge while designing the length of bridge and its single span. After the physical process study the shrinkage and creep of concrete, bending up by prestressing in general PSM bridge, relaxation of tendons as time goes by after post-tension, the conclusion of such a study is applied to the Puk-Han River Bridge in this construction field.

  • PDF