• Title/Summary/Keyword: slab bridge

Search Result 418, Processing Time 0.025 seconds

Acoustic emission localization in concrete using a wireless air-coupled monitoring system

  • Yunshan Bai;Yuanxue Liu;Guangjian Gao;Shuang Su
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.195-205
    • /
    • 2023
  • The contact acoustic emission (AE) monitoring system is time-consuming and costly for monitoring concrete structures in large scope, in addition, the great difference in acoustic impedance between air and concrete makes the detection process inconvenient. In this work, we broaden the conventional AE source localization method for concrete to the non-contact (air-coupled) micro-electromechanical system (MEMS) microphones array, which collects the energy-rich leaky Rayleigh waves, instead of the relatively weak P-wave. Finite element method was used for the numerical simulations, it is shown that the propagation velocity of leaky Rayleigh waves traveling along the air-concrete interface agrees with the corresponding theoretical properties of Lamb wave modes in an infinite concrete slab. This structures the basis for implementing a non-contact AE source location approach. Based on the experience gained from numerical studies, experimental studies on the proposed air-coupled AE source location in concrete slabs are carried out. Finally, it is shown that the locating map of AE source can be determined using the proposed system, and the accuracy is sufficient for most field monitoring applications on large plate-like concrete structures, such as tunnel lining and bridge deck.

A Numerical Study on Load Distribution Factors for Simplified Composite H-Beam Panel Bridges (강합성 초간편 H형강 교량의 하중분배계수에 관한 해석적 연구)

  • Park, Jong Sup;Kim, Jae Heung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.221-232
    • /
    • 2009
  • The load distribution factor (LDF) values of simplified composite H beam panel bridges (SCHPBs) that were subjected to one lane and two lane loads were investigated using three dimensional finite element analyses with the computer program ABAQUS (2007). This study considered some design parameters such as the slab thickness, the steel plate thickness, the span length, and the continuity of the SCHPBs in the development of new LDFs. The distribution values that were obtained from these analyses were compared with those from the AASHTO Standard, LRFD, and the equations presented by Tarhini and Frederick, Huo et al., Back and Shin, and Cai. The AASHTO Standard distribution factors for SCHPBs were found to be very conservative. Sometimes, the distribution values from the finite element analyses for interior girders were similar to the results of the AASHTO LRFD, whereas the values for exterior girders were conservative in most cases. The new distribution values that were presented in this study produced LDFs that are more conservative than those from the finite element method. For the simple application of the design to SCHPBs, bridge engineers can use 0.42 for the interior girder and 0.32 for the exterior girder. The proposed values improve the current design procedure for the LDF problem and increase SCHPB design efficiency.

Determination of Optimum Heating Regions for Thermal Prestressing Method Using Artificial Neural Network (인공신경망을 이용한 온도프리스트레싱 공법의 적정 가열구간 설정에 관한 연구)

  • Kim, Jun Hwan;Ahn, Jin-Hee;Kim, Kang Mi;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.695-702
    • /
    • 2007
  • The Thermal Prestressing Method for continuous composite girder bridges is a new design and construction method developed to induce initial composite stresses in the concrete slab at negative bending regions. Due to the induced initial stresses, prevention of tensile cracks at the concrete slab, reduction of steel girder section, and reduction of reinforcing bars are possible. Thus, the construction efficiency can be improved and the construction can be made more economical. The method for determining the optimum heating region of the thermal prestressing method has not been established although such method is essential for improving the efficiency of the design process. The trial-and-error method used in previous studies is far from efficient, and a more rational method for computing optimal heating region is required. In this study, an efficient method for determining the optimum heating region in using the thermal prestressing method was developed based on the neural network algorithm, which is widely adopted to pattern recognition, optimization, diagnosis, and estimation problems in various fields. Back-propagation algorithm, commonly used as a learning algorithm in neural network problems, was used for the training of the neural network. Through case studies of two-span and three-span continuous composite girder bridges using the developed procedure, the optimal heating regions were obtained.

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

Prediction and analysis of structural noise of a box girder using hybrid FE-SEA method

  • Luo, Wen-jun;Zhang, Zi-zheng;Wu, Bao-you;Xu, Chang-jie;Yang, Peng-qi
    • Structural Engineering and Mechanics
    • /
    • v.75 no.4
    • /
    • pp.507-518
    • /
    • 2020
  • With the rapid development of rail transit, rail transit noise needs to be paid more and more attention. In order to accurately and effectively analyze the characteristics of low-frequency noise, a prediction model of vibration of box girder was established based on the hybrid FE-SEA method. When the train speed is 140 km/h, 200 km/h and 250 km/h, the vibration and noise of the box girder induced by the vertical wheel-rail interaction in the frequency range of 20-500 Hz are analyzed. Detailed analysis of the energy level, sound pressure contribution, modal analysis and vibration loss power of each slab at the operating speed of 140 km /h. The results show that: (1) When the train runs at a speed of 140km/h, the roof contributes more to the sound pressure at the far sound field point. Analyzing the frequency range from 20 to 500 Hz: The top plate plays a very important role in controlling sound pressure, contributing up to 70% of the sound pressure at peak frequencies. (2) When the train is traveling at various speeds, the maximum amplitude of structural vibration and noise generated by the viaduct occurs at 50 Hz. The vibration acceleration of the box beam at the far field point and near field point is mainly concentrated in the frequency range of 31.5-100 Hz, which is consistent with the dominant frequency band of wheel-rail force. Therefore, the main frequency of reducing the vibration and noise of the box beam is 31.5-100 Hz. (3) The vibration energy level and sound pressure level of the box bridge at different speeds are basically the same. The laws of vibration energy and sound pressure follow the rules below: web

Investigation of Impact Factor and Response Factor of Simply Supported Bridges due to Eccentric Moving Loads (이동하중의 편측재하에 따른 단순교의 충격계수 및 응답계수 변화 분석)

  • Hong, Sanghyun;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.105-113
    • /
    • 2018
  • The proposed model to predict the bridge load carrying capacity uses the impact response spectrum. The spectrum is based on Euler-Bernoulli beam and the center of the bridge width for the moving load location. Therefore, it is necessary to investigate the eccentric moving load effects on the impact factor and response factor. For this, this study considers 10 m width and two-lane simply supported slab bridges and performs the moving load analysis to investigate the variations of peak impact factor and corresponding response factor. The numerical results show that the eccentric load increases both the static and dynamic displacements, but the impact factor is decreased since the incremental amount of static displacement is bigger than that of dynamic displacement. However, the difference of the impact factors between the center and eccentric loadings is small showing less than 0.5%p. In the response factor, the eccentric loading increases both the static and dynamic response factors, compared to the center loading. The difference of the response factor is only 0.18%p. It shows that the eccentric loading has very small effects on the response factor, thus the impact factor response spectrum which is generated based on the center moving load can be used to determine the response factor.

Vertical Temperature Difference of Steel Box Girder Bridge Considering Asphalt Thickness of Concrete Deck (콘크리트 바닥판의 아스팔트 두께에 따른 강박스거더교의 상하 온도차)

  • Lee, Seong-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.602-608
    • /
    • 2019
  • The purpose of this study was to calculate the temperature difference of the sectional elevation according to the asphalt thickness of the steel box girder bridge deck and provide data on the design basis accordingly. Asphalt thicknesses produced four steel box girder model specimens of 0mm, 50mm, 100m and 150mm. In each model, 17 to 23 temperature sensors were attached to upper concrete and steel box girders. Six temperature gauges were selected to compare the temperature difference with Euro codes. The maximum and lowest temperature were calculated at the reference atmospheric temperature of each model, and the temperature difference (slope) was calculated based on this calculation. Four models of temperature difference are presented at each model. The 0mm to 100mm temperature difference models showed a -0.9 to -1.5 degree lower temperature difference compared to the temperature difference of Euro codes at the top of the slab. Overall, the measured temperature difference was found to be between 5.45% and 8.33% compared to the Euro code. The standard error coefficient, which was calculated by multiplying the average temperature with the standard error, was calculated from a range of 2.50 to 2.51 times the average at the top and bottom. It is estimated that the proposed temperature difference model can be used as a basic data when calculating temperature difference criteria for bridges in Korea.

On-Site Construction Method for U-Girder with Pre-tension and Verification of Analytical Performance of Anchoring Block (프리텐션 U형 거더 현장 제작 방법 및 정착 블록 해석적 성능 검증)

  • Park, Sangki;Kim, Jaehwan;Jung, Kyu-San;Seo, Dong-Woo;Park, Ki-Tae;Jang, Hyun-Ock
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.3
    • /
    • pp.67-77
    • /
    • 2022
  • In South Korea, U-type girder development was attempted as a means to increase the length of I-type girder, but due to the large self-weight according to the post-tension method, the application of rail bridges of 30m or less is typical. There are not many examples of application of pre-tension type girder. This study does not limit the post-tension method, but applies the pre-tension method to induce a reduction in self-weight and materials used due to the reduction of the cross-section. In addition, we intend to apply the on-site pre-tensioning method using the internal reaction arm of the U-type girder. The prestressed concrete U-type girder bridge is composed of a concrete deck slab and a composite section. Compared to the PSC I-type, which is an open cross-section because the cross section is closed, structural performance such as resistance and rigidity is improved, the safety of construction is increased during the manufacturing and erection stage, and the height ratio is reduced due to the reduction of its own weight. Therefore, it is possible to secure the aesthetic scenery and economical of the bridge. As a result, it is expected that efficient construction will be possible with high-quality factory-manufactured members and cast-in-place members. In this paper, the introduction of the pre-tension method on-site and the analytical performance verification of the anchoring block for tension are included.

Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges (이중합성 교량의 복합스터드 전단연결부의 정적강도 평가)

  • Kim, Hyun Ho;Shim, Chang Su;Yun, Kwang Jung;Lee, Pil Goo
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.549-559
    • /
    • 2005
  • A railway bridge with a double composite section is proposed to enhance the structural performance of existing two-girder bridges because the governing design parameter of railway bridges is the flexural stiffness. The concrete deck in negative moment regions is neglected in the design of continuous composite bridges assuming the concrete slab has no resistance to tension. Therefore, the flexural stiffness of the composite section in the negative moment region is reduced resulting in the increase of the depth of the steel section. In order to resolve this disadvantage, several methods are suggested and the double composite section is one of the excellent solutions for extending the span length and increasing the flexural stiffness. In this study, push-out tests on lying studs and mixed stud shear connection with lying and vertical studs were performed to investigate the behavior of the shear connection in the double composite section. Static strength of the shear connection was evaluated through the test results and numerical analyses.

Crack Width Control on Concrete Slab using Half-Depth Precast Panels with Loop Joints (루프이음 반두께 프리캐스트 바닥판을 갖는 콘크리트 바닥판의 균열폭 제어)

  • Kim, Dong Wook;Shim, Chang Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.19-29
    • /
    • 2015
  • As the half-depth precast concrete decks are increasingly applied to the construction sites, researches on connection details have been increased. For design of concrete bridge deck with half-depth precast panels, it is required to provide appropriate details of transverse loop joints between panels. In this paper, the structural performance of precast decks was evaluated to investigate continuity of the proposed loop joint details. From the results, the validity of the joints for the continuity of deck was observed in the aspect of flexural strength and crack control. The ultimate strength increased 1.52 times as the reinforcement spacing in the joint was reduced. In terms of crack control, direct crack width calculation for the loop joint showed appropriate results comparing with measured crack width.