Abstract
In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.
본 연구는 외단열시스템 성능평가의 주요인자인 선형열관류율을 국제규격(ISO)에서 제시하고 있는 평가방법에 의거, 내단열시스템 대비 외단열시스템의 열성능에 대한 우수성을 정량적으로 파악하고, 향후 외단열시스템의 열성능 평가를 위한 기초자료로의 활용을 목적으로 한다. 이를 위해 공동주택의 대표적 열교부위인 3개 부위를 내단열과 외단열 시스템으로 설계하고, 각 부위별 단열형태별로 선형열관류율을 평가하였다. 그 결과, 외벽-발코니 슬라브 부위는 열교차단재 설치가 필수적인 것으로 분석되었으며, 열교차단재를 설치할 경우 외단열시스템이 내단열시스템보다 선형열관류율이 1/2 이상 줄어드는 것으로 나타났다. 측벽-발코니 부위와 같이 슬라브가 외부로 돌출되지 않는 구조에서는 외단열시스템을 적용할 경우, 선형열관류율이 거의 0인 것으로 나타났다. 내단열로 설계된 외벽-경계벽의 경우, 선형열관류율은 0.451W/m 로 내단열로 설계된 외벽-발코니 슬라브 등 열교가 있는 부위와 비슷한 값을 보이며, 외단열로 설치될 경우 이 또한 거의 0인 것으로 나타났다. 향후, 공동주택의 외단열시스템 도입 및 성능평가를 위해서는 국제기준을 적용한 국내 평가기준의 제도화마련이 필요하며, 특히 제도화 마련과정에서 선형열관류율 계산 인자 중의 하나인 벽체길이의 계산방법은 국가차원의 결정이 필요할 것으로 판단된다.