• Title/Summary/Keyword: skin safety

Search Result 748, Processing Time 0.025 seconds

Emission characteristics of volatile organic compounds released from spray products (생활 스프레이 제품의 안전성 조사: 벤젠과 톨루엔 함량을 중심으로)

  • Jo, Hyo-Jae;Kim, Bo-Won;Kim, Yong-Hyun;Lee, Min-Hee;Jo, Sang-Hee;Kim, Ki-Hyun;Kim, Joon-Young;Park, Jun-Ho;Oh, Soo-Min;Lee, Seung-Hwan;Kim, Dong-Yeon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.268-275
    • /
    • 2013
  • Many kinds of liquid spray products are used in livelihood activities these days. Spray products can be distinguished by the target to be sprayed (like into the air or on human skin (body)). Because human can be exposed to volatile organic compounds (VOC) emitted from spray products, some considerations on safety or hazard of spray products should be needed. In this study, emission characteristics of VOCs were investigated against 10 types of liquid spray products (6 skin spray and 4 air spray products). The concentrations of benzene and toluene were determined by gas chromatography/mass spectrometry (GC/MS) equipped with a thermal desorber (TD). Their average concentrations from 6 skin spray products exhibited$ 5.64{\pm}1.95$ ($mean{\pm}S.D$) and $8.52{\pm}2.89$ ppb(w), respectively. In contrast, those of 4 air spray samples had $7.30{\pm}1.31$ and $7.19{\pm}1.78$ ppb(w), respectively. If liquid contents in spray samples are completely vaporized in one cubic meter (1 m3) after spraying for 10 seconds, their mean concentrations of skin spray products are $31.7{\pm}8.80$ (benzene) and $50.5{\pm}17.1{\mu}g/Sm^3$ (toluene). In contrast, those of air spray products are $24.0{\pm}4.30$ (benzene) and $23.6{\pm}5.83{\mu}g/Sm^3$ (toluene). The estimated concentration levels of benzene from two types of products (31.7 and $24.0{\mu}/Sm^3$) exceeded the Korean atmospheric environmental guideline ($5{\mu}g/Sm^3$). The results of this study thus suggest that some measures should be made to reduce or suppress the contents of VOC in spray products.

Analysis of Octyl-2-Cyanoacrylate as a Dressing Material after Pediatric Urological Procedures (소아비뇨기과 관혈적 수술 시 피부봉합제로 사용된 Octyl-2-Cyanoacrylate (Dermabond$^{TM}$)의 효용성)

  • Lee, Hahn-Ey;Min, Sun Ho;Kim, Kwang Myung
    • Childhood Kidney Diseases
    • /
    • v.16 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • Purpose: We aimed to evaluate the efficacy of Octyl-2-cyanoacrylate (Dermabond$^{TM}$) as a topical skin adhesive for pediatric urologic open surgery. Methods: From August 2010 to August 2011, we retrospectively evaluated pediatric patients who underwent urologic open surgery at our institution. A total of 128 pediatric patients with 210 incisions used Dermabond$^{TM}$ for skin closure. Results: We divided the 128 patients into 3 groups according to type of surgery. Group 1 underwent hydrocelectomy (55 cases, 41.3%), Group 2 underwent orchiopexy (43 cases, 32.3%), Group 3 underwent penoplasty (35 cases, 26.4%). One hundred and twenty eight patients who underwent 133 surgeries in total, with a total of 210 incisions visited our outpatient department postoperatively, and a total of 5 wound complications (2.3%) occurred, but were simple inflammations and no dehiscence was observed. When analyzed according to groups, no wound problems occurred in Group 1 (0/55, 0%), one occurred in Group 2 (1/43, 2.3%) and four cases occurred in Group 3 (4/35, 11.4%) respectively. When re-analyzed according to wound locations, one occurred in an inguinal wound (1/120, 0.83%), none occurred in scrotal wounds (0/55, 0%), and four occurred in penile wounds (4/35, 11.4%). In Group 3, the incidence of penile wounds was significantly increased compared to other groups (P=0.008). All 5 wound problems were inflammatory and healed at an average of 13.8 days (13-15 days) with antibiotic ointment application only. Conclusion: Dermabond$^{TM}$ is feasible and safe topical skin adhesive alternative to standard skin suture in pediatric urologic surgery. However, further research about its efficacy and safety could be valuable in the future.

Formation of Liquid Crystalline with Hydrogenated Lecithin and Its Effectiveness (수소첨가레시친을 이용한 액정 젤의 형성과 보습효과)

  • Kim, In-Young;Lee, Joo-Dong;Ryoo, Hee-Chang;Zhoh, Choon-Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.159-165
    • /
    • 2004
  • This study described about method that forms liquid crystal gel (LCG) by main ingredient with hydrogenated lechin (HL) in O/W emulsion system. Result of stability test is as following with most suitable LCG's composition. Composition of LCG is as following, to form liquid crystal, an emulsifier used 4.0wt% of cetostearyl alcohol (CA) by 4.0wt% of HL as a booster. Moisturizers contained 2wt% of glycerin and 3.0wt% of 1,3-butylene glycol (1,3-BG). Suitable emollients used 3.0wt% of cyclomethicone, 3.0wt% of isononyl isononanoate (ININ), 3.0wt% of cerpric/carprylic triglycerides (CCTG), 3.0wt% of macademia nut oil (MNO) in liquid crystal gel formation. On optimum conditions of LCG formation, the pHs were formed all well under acidity or alkalinity conditions (pH=4.0-11.0). Considering safety of skin, pH was the most suitable 6.0${\pm}$1.0 ranges. The stable hardness of LCG formation appeared best in 32 dyne/$\textrm{cm}^2$. Particle of LCG is forming size of 1-20$\mu\textrm{m}$ range, and confirmed that the most excellent LCG is formed in 1-6$\mu\textrm{m}$ range. According to result that observe shape of LCG with optical or polarization microscope, LCG could was formed, and confirmed that is forming multi -layer lamellar type structure around the LCG. Moisturizing effect measured clinical test about 20 volunteers. As a result, moisturizing effect of LCG compares to placebo cream was increased 36.6%. This could predicted that polyol group is appeared the actual state because is adsorbed much to round liquid crystal droplets to multi-lamellar layer's hydrophilic group. It could predicted that polyol group is vast quantity present phase that appear mixed because is adsorbed to round liquid crystal to multi-lamellar layer's hydrophilic group. This LCG formation theory may contribute greatly in cosmetics and pharmacy industry development.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Korean Medicine for Thoracolumbar Compression Fracture in Korean Literature : a Systematic Review (흉요추 압박 골절의 한의학적 치료에 대한 국내 임상 근거 : 체계적 문헌 고찰)

  • Bae, Ji Min;Kim, Dae Hun;Kim, Jae Kyu;Lee, Byung Ryul;Yang, Gi Young;Kim, Kun Hyung
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.147-156
    • /
    • 2015
  • Objectives : This study aims to evaluate the effectiveness and safety of Korean medicine for a thoracolumbar compression fracture. Methods : We searched six Korean databases (DBPIA, Korean Studies Information Service System, Oriental Medicine Advanced Searching Integrated System, National Digital Science Library, Research Information Sharing Service, KoreaMed) (up to June 2015) and the Journal of Korean Acupuncture and Moxibustion Society. Unpublished studies were also searched. Clinical research, other than case reports involving less than 10 patients, were eligible. The effectiveness and safety of Korean Medicine was analyzed. The 'Risk of Bias' was assessed using the 'Risk of Bias' assessment tool for non-randomized studies as well as the Cochrane Collaboration's 'Risk of Bias' tool. Results : We found 12 before-after studies (374 patients). There was no randomized trial. All studies combined at least three different types of Korean medicine treatments. The period of treatment varied between less a week and 154 days. All the included studies reported improvements in pain, functional disability related to lower back pain, global assessment, and benefits in the compression ratio of a fractured vertebrae and skin temperature measured by digital infrared thermal imaging in comparison with the baseline. However, all studies had a high risk of bias and three studies reported mild adverse events. Conclusions : There is no randomized trial for the role of Korean medicine for patients with a thoracolumbar compression fracture. The effectiveness and safety of Korean medicine for this population remains unclear. Findings in this review are seriously biased due to observational design and a high risk of bias included in the studies. Future high-quality randomized trials are warranted.

CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy

  • Jeon, Min-Cheol;Kim, Ju Ock;Jung, Sung Soo;Park, Hee Sun;Lee, Jeong Eun;Moon, Jae Young;Chung, Chae Uk;Kang, Da Hyun;Park, Dong Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.330-338
    • /
    • 2018
  • Background: We developed an additional laser guidance system to improve the efficacy and safety of conventional computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB), and we conducted this study to evaluate the efficacy and safety of our system. Methods: We retrospectively analyzed the medical records of 244 patients who underwent CT-guided PTNB using our additional laser guidance system from July 1, 2015, to January 20, 2016. Results: There were nine false-negative results among the 238 total cases. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of our system for diagnosing malignancy were 94.4% (152/161), 100% (77/77), 100% (152/152), 89.5% (77/86), and 96.2% (229/238), respectively. The results of univariate analysis showed that the risk factors for a false-negative result were male sex (p=0.029), a final diagnosis of malignancy (p=0.033), a lesion in the lower lobe (p=0.035), shorter distance from the skin to the target lesion (p=0.003), and shorter distance from the pleura to the target lesion (p=0.006). The overall complication rate was 30.5% (74/243). Pneumothorax, hemoptysis, and hemothorax occurred in 21.8% (53/243), 9.1% (22/243), and 1.6% (4/243) of cases, respectively. Conclusion: The additional laser guidance system might be a highly economical and efficient method to improve the diagnostic efficacy and safety of conventional CT-guided PTNB even if performed by inexperienced pulmonologists.

A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety

  • Pak, Chang Sik;Chang, Lan Sook;Lee, Hobin;Jeong, Jae Hoon;Jeong, Jinwook;Yoon, Eul-Sik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.572-579
    • /
    • 2015
  • Background Facial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation. Methods Thirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events. Results The treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events. Conclusions Face lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

Embryo-Fetal Developmental Toxicity Study of Methoxycinnamidopropyl Polysilsesquioxane (Methoxycinnamidopropyl Polysilsesquioxane의 랫드를 이용한 배.태자 발생독성 연구)

  • Hong, Jeong-Sup;Lim, Jeong-Hyeon;Kim, Kang-Hyun;Park, Myeong-Kyu;Jo, Ki-Yeon;Park, Gil-Jong;Jung, Taek-Kyu;Kim, Ja-Young;Yoon, Kyung-Sup
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.3
    • /
    • pp.247-256
    • /
    • 2011
  • Existing organic UV protection materials seem to be problematic due to their penetration and irritation to skin. Inorganic UV protection materials are also at issue for safety of their nano-type transformation. Therefore, the recent studies of UV protection materials have been focused not only on the effectiveness but also on their safety. One of the UV protection materials in study which have higher safety is the organic-inorganic conjugation type UV protection material. Previously, we have reported the manufacturing process, physical property and UV protection efficiency of methoxychinnamidoprophy poloysilsesquixan as a new cross-linked polymer type UV protection material. In this study, we have evaluated the effect of the methoxychinnamidoprophy poloysilsesquixan on embryo-fetal development in SD rats. This study is expected to show some definite information related to the effect on pregnancy or embryo-fetal abnormality in case of the clinical exposure of the methoxychinnamidoprophy poloysilsesquixan.

A study on damage prediction analysis for styrene monomer fire explosion accidents (스티렌 모노머 화재폭발사고 피해예측 분석에 관한 연구)

  • Hyung-Su Choi;Min-Je Choi;Guy-Sun Cho
    • Industry Promotion Research
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • This study selected the worst-case scenario for fireball and vapor cloud explosion (VCE) of a styrene monomer storage tank installed in a petrochemical production plant and performed damage prediction and accident impact analysis. The range of influence of radiant heat and overpressure due to fireball and vapor VCE during the abnormal polymerization reaction of styrene monomer, the main component of the mixed residue oil storage tank, was quantitatively analyzed by applying the e-CA accident damage prediction program. The damage impact areas of radiant heat and explosion overpressure are analyzed to have a maximum radius of 1,150m and 626m, respectively. People within 1,150m of radiant heat of 4kW/m2 may have their skin swell when exposed to it for 20 seconds. In buildings within 626m, where an explosion overpressure of 21kPa is applied, steel structures may be damaged and separated from the foundation, and people may suffer physical injuries. In the event of a fire, explosion or leak, determine the risk standards such as the degree of risk and acceptability to workers in the work place, nearby residents, or surrounding facilities due to radiant heat or overpressure, identify the hazards and risks of the materials handled, and establish an emergency response system. It is expected that it will be helpful in establishing measures to minimize damage to workplaces through improvement and investment activities.

An Experimental Study on Bearing Capacity of Drilled Shaft with Mid-size (중구경 현장타설말뚝의 지지력 특성에 관한 실험적 연구)

  • Lee, Kwang-Wu;You, Seung-Kyong;Park, Jeong-Jun;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.263-272
    • /
    • 2019
  • This paper describes the results of bearing capacity using field loading test of pile, in order to extend the applicability of drilled shaft with mid-size, and the results were compared with the prediction results of design bearing capacity by empirical formular. The static load test result showed that the allowable bearing capacity of high pile strength was about 2.4 times higher than that of low pile strength. The dynamic load test result showed that the allowable bearing capacity of high pile strength was about 1.4 times~1.5 times higher than that of low pile strength. The comparison result of allowable bearing capacity between static and dynamic load test showed that the difference of allowable load ranged from 3% to 6% under the same settlement conditions. As a result of comparing the ultimate bearing capacity by load test and design bearing capacity, it was found that the FHWA proposed equation could be more reasonable than the other proposed equation in load sharing ratios of end bearing and skin friction.