• Title/Summary/Keyword: skin measurement

Search Result 625, Processing Time 0.031 seconds

The Application of Abelmoschus manihot jinhuakui Extracts as Cosmetic Ingredient (금화규(Abelmoschus manihot jinhuakui) 추출물의 화장품 소재로서의 응용)

  • Jeon, Yun-Hong;Kang, Sang-Mo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.10
    • /
    • pp.290-297
    • /
    • 2020
  • This study focuses on figuring out the possibility of cosmetics raw materials, especially the A. manihot jinhuakui, The viscosity of the frozen-dried extracts were all increased according to the added concentration, and the high viscosity of the WF extracted with water-based alkaline solvent was confirmed. We used snail mucus to compare the viscosity of the A. manihot jinhuakui. We generated the emulsions of experimental groups with 10% of freezing and drying A. manihot jinhuakui and control group emulsions with 10% of freezing and drying snail mucus. By the results, it shows that the WF experimental group had the highest incremental viscosity rates as 129,200 cPs. In the elastic changes and moisture measurement of the skin, the A. manihot jinhuakui extracts growth rate was the highest more than snail mucus. It demonstrated the possibility of cosmetics raw materials in A. manihot jinhuakui, which takes into account the properties of natural products.

Multi-Modal User Distance Estimation System based on Mobile Device (모바일 디바이스 기반의 멀티 모달 사용자 거리 추정 시스템)

  • Oh, Byung-Hun;Hong, Kwang-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • This paper present the multi-modal user distance estimation system using mono camera and mono microphone basically equipped with a mobile device. In case of a distance estimation method using an image, we is estimated a distance of the user through the skin color region extraction step, a noise removal step, the face and eyes region detection step. On the other hand, in case of a distance estimation method using speech, we calculates the absolute difference between the value of the sample of speech input. The largest peak value of the calculated difference value is selected and samples before and after the peak are specified as the ROI(Region of Interest). The samples specified perform FFT(Fast Fourier Transform) and calculate the magnitude of the frequency domain. Magnitude obtained is compared with the distance model to calculate the likelihood. We is estimated user distance by adding with weights in the sorted value. The result of an experiment using the multi-modal method shows more improved measurement value than that of single modality.

Estimation of Pull-out Behavior for Steel Pile Nailing installed Foldable Wedge by Field Measurement (현장계측에 의한 접이식 웨지 장착 강관네일의 인발거동 평가)

  • Kwon, Kyo-Keun;Choi, Bong-Hyuck;Kim, Kyung-Min
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.4
    • /
    • pp.19-25
    • /
    • 2009
  • In this study, field pull-out tests were performed for steel pipe nailing installed foldable wedge and non-wedge type steel pipe nailing under the same test conditions. This is to evaluate pull-out resistance improvement effect of steel pipe nailing installed foldable wedge. Evaluating for field pull-out characteristics of steel pipe nailing installed foldable wedge was performed through analysis of ultimate pull-out resistance ($T_L$), ultimate unit skin friction ($q_s$, $u_{max}$), tensile normal stiffness ($K_{\beta}$), tension of nail. As a result, the steel pipe nailing installed foldable wedge have an effect of pull-out resistance increased about 30% in comparison with non-wedge type steel pipe nailing.

  • PDF

Doppler Radar System for Noncontact Bio-signal measurement (비접촉 방식의 생체 신호 측정을 위한 도플러 레이더 시스템)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.357-359
    • /
    • 2009
  • In this paper, the 2.4GHz doppler radar system consisting of the doppler radar module and a baseband module were designed to detect heartbeat and respiration signal without direct skin contact. A bio-radar system emits continuous RF signal of 2.4GHz toward human chest, and then detects the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from quadrature signal of the doppler radar system are applied to the pre-processing circuit, amplification circuit, and the offset circuit of the baseband module. ECG(electrocardiogram) and reference respiration signals are measured simultaneously to evaluate the doppler radar system. As a result, the respiration signal of doppler radar signal is detected to 1m without complex digital signal processing. The sensitivity and calculated from I/Q respiration signal were $98.29{\pm}1.79%$, $97.11{\pm}2.75%$, respectively, and positive predictivity were $98.11{\pm}1.45%$, $92.21{\pm}10.92%$, respectively. The sensitivity and positive predictivity calculated from phase and magnitude of the doppler radar were $95.17{\pm}5.33%$, $94.99{\pm}5.43%$, respectively. In this paper, we confirmed that noncontact real-time heartbeat and respiration detection using the doppler radar system has the possibility and limitation.

  • PDF

Study of Physico-Chemical Properties of N,N-Diacyl, O-Acyl Chitosan Oligomer (N,N-디아실, O-아실 키토산 올리고머의 물리화학적 특성에 관한 연구)

  • Lee, Ok-Sub;Ha, Byung-Jo;Kim, Jun-Oh;Park, Soeng-Kyu;Lee, Yoon-Sik
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.365-373
    • /
    • 1997
  • Chitosan oligomer having aldehyde group at reducing end was prepared by oxidative-deamination reaction of chitosan by using sodium nitrite, and the resulting aldehyde group was redeced to 2,5-anhydro-D-mannitol group. The obtained chitosan oligomer showed an average degree of polymerization(DP) 2 by GPC analysis. It was highly soluble in lipophilic solvents. N,N-diacyl, O-acyl chitosan oligomer was obtained trom the reaction between chitosan oligomer and acyl chloride under 4-dimethoxyaminopyridine catalyst. From DSC measurement, N,N-dilauroyl, O-lauroyl chitosan oligomer showed mesophase region, which was confirmed by polarizing microscope as thermotropic liquid crystalline state. X-ray diffraction pattern revealed that N,N-dilauroyl, O-lauroyl chitosan oligomer was highly crystalline, whereas chitosan oligomer was not.

  • PDF

Visualization of Microbubbles Affecting Drag Reduction in Turbulent Boundary Layer (마찰저항 감소에 영향을 주는 난류 경계층 내 미세기포(microbubble)의 가시화 연구)

  • Paik, Bu-Geun;Yim, Geun-Tae;Kim, Kwang-Soo;Kim, Kyoung-Youl;Kim, Yoo-Chul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.4
    • /
    • pp.356-363
    • /
    • 2015
  • Microbubbles moving in the turbulent boundary layer are visualized and investigated in the point of frictional drag reduction. The turbulent boundary layer is formed beneath the surface of the 2-D flat plate located in the tunnel test section. The microbubble generator produces mean bubble diameter of 30 – 50 μm. To capture the micro-bubbles passing through the tiny measurement area of 5.6 mm2 to 200 mm2, the shadowgraphy system is employed appropriately to illuminate bubbles. The velocity field of bubbles reveals that Reynolds stress is reduced in the boundary layer by microbubbles’ activity. To understand the contribution of microbubbles to the drag reduction rate more, much smaller field-of-view is required to visualize the bubble behaviors and to find the 2-D void fraction in the inner boundary layer.

A Cell-Based Assay System for Monitoring NF-$\kappa$B Activity in Human Epidermal Keratinocytes: A Screening Tool of the Antioxidants and Anti-inflammatories for Dermatological Purpose

  • Moon, Ki-Young;Hahn, Bum-Soo;Lee, Jinseon;Kim, Yeong-Shik
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.27 no.1
    • /
    • pp.17-27
    • /
    • 2001
  • A cell-based assay system for monitoring NF-$textsc{k}$B activity was developed to determine the influence of activated NF-$textsc{k}$B in human HaCaT cells. The pNF-$textsc{k}$B-SEAP-NPT plasmid that permits expression of the secreted alkaline phosphatase (SEAP) reported gene in response to the NF-$textsc{k}$B activity and contains neomycin phosphotransferase (NPT) gene for the geneticin resistance in host cells was constructed and transfected into human keratinocyte cell line HaCaT. Human HaCaT transfectant cells secreted the SEAP enzyme into the culture medium in a time-dependent manner until 72h. NF-$textsc{k}$B activities were measured in the SEAP reporter gene assay using a fluorescent detection method. The treatment of HaCaT cell transfectants with known antioxidants [e.g., N-acetyl-L-cysteine and vitamin C] showed inhibition of NF-$textsc{k}$B activity in a time-and concentration-dependent manner. The phorbol 12-myristate 13-acetate (PMA) known as a stimulator of NF-$textsc{k}$B expression demonstrated that it increased NF-$textsc{k}$B activity in a time- and concentration-dependent manner. This assay system could be used to determine the quantitative measurement of NF-$textsc{k}$B activity in the human skin and allow the screening of anti-inflammatory agents from various synthetic chemicals and natural products for dermatological purpose. Abbrevitions used: NF-$textsc{k}$B, nuclear factor kappa B; I-$textsc{k}$B, Inhibitory kappa B; SEAP, secreted alkaline phosphatase; NPT, neomycin phosphotransferease; PCR, polymerase chain reaction: dNTP, deoxynucleoside triphosphates; DMEM, dulbecco’s modified eagle medium; FBS, fetal bovine serum; PBs, phosphate-buffered saline; MUP, 4-methylumbellifery phosphate; NAC, N-acetyl-L-cysteine; DMSO, dimethyl sulfoxide; PMA, phorbol 12-myristate 13-acetate.

  • PDF

Development of Pulse Diagnosis Hold-down Pressure Measurement System (맥진 가압 프로파일 측정 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Ryu, Hyun-Hee;Woo, Young-Jae;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1997-1998
    • /
    • 2008
  • Pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors. Although the pulse diagnosis position, Gwan is apart from Chon or Cheok by 10$\sim$20mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Chon, Gwan and Cheok. One the other hand, the education on pulse diagnosis behavior includes tantalizing problem caused by no tool for communication between trainer and trainee. On account of this situation, we tried to develop a system which can measure the hold-down pressure during a pulse diagnosis and compare the hold-down pressure profile of trainer and that of trainee. This system can be divided into three parts - pulse pressure sensing part, signal acquisition part and data storing part. A correction curve was generated by the relation between output voltages and standard weights. Using this system, 3 channel hold-down pressure profile of a oriental medical doctor were recorded three times. In the profile, three period were observed and all period included two process for searching the depth of pulsation and for classifying the pulse feeling into one or more of 28 pulse types. The maximum value of pulse profile was 1.3$kg{\cdot}f$ which was more than reported by previous chinese groups and the mean values of three channel ranged from 240$g{\cdot}f$ to 430$g{\cdot}f$. In frequency domain, each channel has some dominant frequency components - about 10Hz, 35Hz and 75Hz. In further study, we want to collect more profiles from lage number of oriental medicine doctors and hope to develop a measuring system which can measure the hold-down pressure on subject's skin directly.

  • PDF

Case study of volume loss estimation during slurry tbm tunnelling in weathered zone of granite rock (화강풍화대를 통과하는 슬러리 TBM의 체적손실 산정에 대한 사례 연구)

  • Park, Hyunku;Oh, Ju-Young;Chang, Seokbue;Lee, Seungbok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.61-74
    • /
    • 2016
  • This paper presents a case study on the ground settlement and volume loss estimation for slurry pressure balanced shield TBM tunnelling in weathered zone of granite rock. Settlement at each stage of shield tunnelling was analyzed and the volume losses and settlement trough factors were estimated from observations. In addition, using the existing volume loss evaluation method in literature, volume losses were estimated considering ground properties and actual driving parameters. Most of ground settlement occurred during passage of shield skin passage and after backfill grouting, and the measured total volume loss and trough curves appeared to coincide with literature. Shield and tail loss obtained from field measurement were found to be around 90% and 60% of the predictions, where tail loss indicated larger deviation than shield loss.

Effects of Body Postures on Garment Pressure in Daily Wear (평상복 착용시 인체의 자세가 의복압에 미친 영향)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.13 no.1
    • /
    • pp.153-158
    • /
    • 2004
  • With considerable development of comfortable and functional clothing in recent years, we need to evaluate the effects of garment pressure in daily wear on each parts of human body because the garment pressure is important to design the clothing. This study was designed to examine the effects of body postures on garment pressure on each parts of human body in the actual clothing conditions. All the data were collected from 50 volunteered subjects. The Garment pressure was measured in lune and December with 8 points CPMS clothing pressure system from scapular, upper am, elbow, under arm, front waist line, side waist line, abdomen, crista ilica, upper hip, middle hip, front thigh, back thigh, front knee and back knee. The postures of subjects were controlled with 3 positions such as standing (posture 1), sitting on the chair (posture 2), and sitting on the floor (posture 3) during measurement of clothing pressure. Clothing weights were more in men than in woman. It showed that clothing weights had no effects on the garment pressure. In this study, however, just the garment pressures on scapular and top of the hip increased significantly by clothing weight (p<. 05). Clothing horizontally pressed on scapular and top of hip but not on other parts. When subjects stood up, the garment pressure was the highest on the side waist. Especially, clothing pressure on the front waist point was lower than that of the left side waist. On the upper parts of the human body, the garment pressure of left side waist was the highest, and followed by front waist, crista ilica, and abdomen in order. When subjects were sitting on the chair, the garment pressure on the lower parts of the human body was the highest on the top of hip. When the subjects were sitting on the chair or on the floor, the surface area on their skin of hip and waist parts increased by postures. In addition, it showed that men felt more comfortable than women on higher clothing pressure level.

  • PDF