• Title/Summary/Keyword: size fit

Search Result 799, Processing Time 0.027 seconds

Actual Wearing Conditions and Fitting Problems of Ready-to-wear Garment for Tween Generation Boys aged from 12 to 14 (만(滿) $12{\sim}14$세(歲) 트윈 세대(世代) 남학생(男學生)의 의복(衣服) 착용실태(着用實態) 및 맞음새 연구(硏究))

  • Kim, Kyung-A
    • Journal of Fashion Business
    • /
    • v.8 no.5
    • /
    • pp.85-99
    • /
    • 2004
  • The purpose of the study is to survey the current state of tween generation boys' clothing-wearing, to identify problems in the current apparel sizing system, and to contribute to the improvement of the fitness of ready-made clothes. 1. According to the result of surveying the current state of clothing-wearing, boys prefer casual wear and, as they grow old, they tend to purchase clothes alone or in company with their friends. In addition, they use mainly easy casual wear or sports wear stores. They appear to be highly dissatisfied with price and size and think that the fitting of coats, pants and jackets is poor. Moreover, they complain about sizes such as waist circumference, pants length and upper-arm circumference. 2. According to the result of comparing apparel sizing system with body measurements, the waist circumference and hip circumference of young casual wear are fit to the large size of body at the age of 12 and the over-average size of body at the age of 13 and 14, but its bust circumference is fit only to the extra-large size of body at the age of 13 and 14. Such results come from differences in body shape between adults and adolescents. Although adolescents' body size has been enlarged, their body line is still immature and, accordingly, their drop-value is smaller than that of adults, which appears to cause adolescents to be highly dissatisfied with fitting.

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

Environmental Dependence of Luminosity-Size Relation of Local Galaxies

  • Ann, Hong Bae
    • Journal of the Korean earth science society
    • /
    • v.38 no.5
    • /
    • pp.333-344
    • /
    • 2017
  • We present the environmental dependence of the luminosity-size relation of galaxies in the local universe (z < 0.01) along with their dependence on galaxy morphology represented by five broad types (E, dEs, S0, Sp, and Irr). The environmental parameters we consider are the local background density and the group/cluster membership together with the clustercenteric distance for the Virgo cluster galaxies. We derive the regression coefficient (${\beta}$), i.e., the slope of the line representing the least-squares fitting to the data and the Pearson correlation coefficient (c.c.) representing the goodness of the least-squares fit along with the confidence interval from bootstrap resampling. We find no significant dependence of the luminosity-size relation on galaxy morphology. However, there is a weak dependence of the luminosity-size relations on the environment of galaxies, in the sense that galaxies in the low density environment have shallower slopes than galaxies in the high density regions except for elliptical galaxies that show an opposite trend.

Kullback-Leibler Information-Based Tests of Fit for Inverse Gaussian Distribution (역가우스분포에 대한 쿨백-라이블러 정보 기반 적합도 검정)

  • Choi, Byung-Jin
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1271-1284
    • /
    • 2011
  • The entropy-based test of fit for the inverse Gaussian distribution presented by Mudholkar and Tian(2002) can only be applied to the composite hypothesis that a sample is drawn from an inverse Gaussian distribution with both the location and scale parameters unknown. In application, however, a researcher may want a test of fit either for an inverse Gaussian distribution with one parameter known or for an inverse Gaussian distribution with both the two partameters known. In this paper, we introduce tests of fit for the inverse Gaussian distribution based on the Kullback-Leibler information as an extension of the entropy-based test. A window size should be chosen to implement the proposed tests. By means of Monte Carlo simulations, window sizes are determined for a wide range of sample sizes and the corresponding critical values of the test statistics are estimated. The results of power analysis for various alternatives report that the Kullback-Leibler information-based goodness-of-fit tests have good power.

A Study on Actual Conditions of Glove Size Standards - Focused on KS and ISO Sizing System- (장갑의 치수규격 실태에 관한 연구 - KS와 ISO 치수체계를 중심으로 -)

  • 김은경;최혜선
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.6
    • /
    • pp.77-90
    • /
    • 2004
  • The purpose of this study was to provide basic information requisite in the new sizing system for gloves. KS glove standards' size dimensions, size designation and labeling systems were analyzed. Also, KS glove standards' control sizes were compared to the anthropometric data of 824 Korean adults taken in the previous study. As well, the ISO hand size system was also compared to the anthropometric data of the previous study according to frequency tables of hand length and hand circumference. The size dimensions showed differences among KS standards and there was no size designation and labeling systems existed in KS standards. Among KS glove size systems, protective rubber gloves for radioactive contamination and surgical rubber gloves' size which followed ISO system were accurately indicate the hand size of the person a glove is intended to fit. ISO glove sizing system comprised the control dimensions of hand length and hand circumference. The coverage of ISO size A was 84.8% which was highest among ISO size A. B, C. And in hand circumference 178, 191, 203, 216mm showed the frequencies above 3% and in hand length 167, 175. 183, 191, 199mm showed the frequencies above 3%.

Korean adolescent girls' brassiere size demand (한국 청소년기 여성의 브래지어 사이즈 수요특성에 관한 연구)

  • Kim, Dohkyung;Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.1
    • /
    • pp.24-31
    • /
    • 2015
  • The purpose of this study was to define Korean adolescent girls' brassiere size demand features in order to improve the suitability of junior brassieres for adolescent girls. The subjects for the data collection were Korean teenage girls from age 13 to 17 (n=492). Their body size was collected by conducting anthropometric measurement. The results of this study show that not only the growth of height, but also the growth of the body length is almost finished at the age of 15. The brassiere cup size, which shows the breast growth directly, increased remarkably at age 13 to 14, and once again at age 17. The demand for brassiere band size 70 appeared generally high among all ages. The research also suggests that the band size 60 and over 85 is also needed among the teenage girls. In matters of the brassiere cup size, junior brassieres over B-cup size are also necessary for teenage girls with big breasts to support their heavy breast weight. These results imply that the junior brassiere companies should improve their brassiere size range to fit the teenage girls' breasts properly.

IN VITRO MARGINAL FIT OF THE COMPUTERAIDED MILLED CERCON CROWNS

  • Chang, Jae-Yoon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.306-313
    • /
    • 2005
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of sample size, measurement number, measuring , instruments, etc. And there have been few studies about the marginal fit of Computer-aided Cercon crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made using computer-aided milled Cercon crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and methods. The in vitro marginal discrepancies of computer-aided milled Cercon crowns and control groups (metal ceramic crowns) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared by milling machine. 30 crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. The means and standard deviations of the marginal fit were 85$\pm$22$\mu$m for the control group and 91$\pm$15$\mu$m for the Cercon crowns. The t-test of the marginal discrepancies between Cercon crowns and metal-ceramic crowns were performed. Significant differences were not found between groups (P=0.230>.05). Based on the criterion of 120$\mu$m as the limit of clinical acceptability, the mean marginal fits of Cercon crowns and metal-ceramic crowns were acceptable. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were 85$\pm$22$\mu$m for the control (metal-ceramic crowns), 91$\pm$15$\mu$m for Cercon crowns. 2. The Cercon crowns showed slightly larger marginal gap discrepancy than the control but marginal gap between Computer-aided milled Cercon crowns and metal ceramic crowns did not showed significant difference (P>.05). 3. The Cercon crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

A Study on Sizing System and Wearing Conditions with School Uniform Pants for Highschool Girls (여고생 바지 교복의 사이즈 체계 및 착용 실태에 관한 연구)

  • Choi, Eun-Hee;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.286-293
    • /
    • 2012
  • The purpose of this study was conducted to provide basic information on developing highschool-uniform pants with more suitable fit. To carry out this study, questionnaires were administered to 187 students in high schools in Gwangju. The collected data were analyzed with frequencies statistics, t-test, ANOVA using the SPSS WIN 18.0. The results are as follows; As results of research on highschool-uniform regulation, 88% of the highschool in Gwangju allowed their students to wear school uniform pants. As results of investigation on the school-uniform pants sizing system of manufacturing firm, it was found that there's a trend towards increasing a large size with the change body type. The size labelling for school uniform pants was waist circumference-stature. There were differences in pants sizes according to the manufacturing firm and body measurements such as hip circumference, in seam length, pants length. As results of survey on wearing conditions, the selection of school uniform pants has increased in winter season. The most important body measurement in the choice of purchase was thigh circumference. In fit of uniform pants, respondents answered that waist circumference and hip circumference became smaller according to the physical growth.

Design and Implementation of XML Authoring Tool for Digital Document on M-Commerce: X-Auth (모바일 전자 상거래에 적합한 전자 문서의 XML 저작 도구 설계 및 구현: X-Auth)

  • 강성민;황기태;김남윤
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2B
    • /
    • pp.289-298
    • /
    • 2004
  • Recently, mobile commerce is widely spread around the world according to fast growth of the mobile communication market. The existing digital document is not well fit in mobile commerce because of weakness of the hardware of mobile devices, low bandwidth of wireless communication, and the constraints of the size and resolution of the display. In this paper, we analyzed the elements of the digital document proper for mobile commerce based on wireless communication, designed the XML form for the digital document, and implemented the X-Auth which is an authoring tool for the XML digital document. X-Auth does not require that the author or user know XML. And also it makes it possible to create the digital document fit for the size of the mobile device display and therefore remove inconvenience due to the scrolls.

Phase Doppler Measurements and Probability Density Functions in Liquid Fuel Spray (연료분무의 위상도플러 측정과 확률밀도함수의 도출)

  • 구자예
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1039-1049
    • /
    • 1994
  • The intermitternt and transient fuel spray have been investigated from the simultaneous measurement of droplet sizes and velocities by using Phase/Doppler Particle Analyzer(PDPA). Measurement have been done on the spray axis and at the edge of the spray near nozzle at various gas-to-liquid density ratios(.rho./sub g//.rho./sub l/) that ranges from those found in free atmospheric jets to conditions typical of diesel engines. Probability density distributions of the droplet size and velocity were obtained from raw data and mathematical probability density functions which can fit the experimental distribations were extracted using the principle of maximum likelihood. In the near nozzle region on the spray axis, droplet sizes ranged from the lower limit of the measurement system to the order of nozzle diameter for all (.rho./sub g/ /.rho./sub l/) and droplet sizes tended to be small on the spray edge. At the edge of spray, average droplet velocity peaked during needle opening and needle closing. The rms intensity is greatly incresed as the radial distance from the nozzle is increased. The probability density function which can best fit the physical breakage process such as breakup of fuel drops is exponecially decreasing log-hypebolic function with 4 parameters.