• 제목/요약/키워드: size difference

검색결과 5,059건 처리시간 0.039초

Free-Size 환자복 개발에 관한연구 (A Study on Developing Patient Clothing of Free-Size)

  • 홍정민
    • 복식
    • /
    • 제47권
    • /
    • pp.113-124
    • /
    • 1999
  • Hospitals in Korea are having trouble with economic matters because of the low cost of medical insurance and the consumer's demand for high-quality care. The management of patient clothing is very difficult Especially for the management of size is very difficult because the mix of patients in the wards is very different from the stocked clothing sizes. Because of economic matters the ward dose not prepare enough clothing for every size. The nurses in the wards have trouble managing the clothing. Therefore the nurses want free-size patient clothing for all patients. The problem of managing the patient's clothing were surveyed by nureses in the wards. It was known that the free-size patient clothing was needed. The clothing designed from 150cm, to 180cm by 5cm were made. The different sizes of clothing were pretested. The experimental clothing were selected. The experimental patient clothing are designed for between from 165cm and 170cm in height which refers to Korean average. The fitness and sensory test were made by medical personnel outpatient who will be future client for hospital and by specialist in clothing. Finally The free-size patient clothing was made. It was said that there is no difference between the C-type (170cm) and the D-typer(165cm) clothing by specialists in clothing. The outpatient future client for hospital liked the C-type was selected. The questionnaires of the C-type patient clothing was tested by outpatient patients and by medical personnel. Eighty-four point-eightprecent(84.8%) of evaluators liked free-size clothing 75.8% liked unisex use.

  • PDF

조경수 뿌리분의 크기가 활착에 미치는 영향 - 계수나무와 벚나무를 대상으로 (The Effect of Tree Root-ball Size on the Regrowth of Landscape Trees - In Case of Cercidiphyllum japonicum and Prunus yedoensis)

  • 홍성래;정대영;심상렬
    • 한국조경학회지
    • /
    • 제31권4호
    • /
    • pp.82-89
    • /
    • 2003
  • This study was carried out to find the suitable root-ball size for the planting construction of landscape trees. Surveyed trees for this study were Cercidiphyllum japonicum and Prunus yedoensis, and the root-ball size was classified into 3D, 4D, 5D, and 6D(D meaning the diameter at the base of a tree). Visual ratings on a scale of 1 to 9 were used as a means for measuring the regrowth strength after planting tested trees. Test trees with 3, 4, 5 and 6D root-ball size were planted on March. 16, 2002 and visual ratings were measured up to April. 30, 2003. Cercidiphyllum japonicum and Prunus yedoensis started showing a difference in regrowth by each rootball size a month after planting. The regrowth quality of Cercidiphyllum japonicum was low at 3D, medium at 4∼5D and high at 6D root-ball size, while the regrowth quality of Prunus yedoensis was low at 3∼4D and medium-high at 5∼6D root-ball size. According to the above results, a root-ball size for good regrowth quality was a little bit different between Cercidiphyllum japonicum and Prunus yedoensis. 4D of Cercidiphyllum japonicum and 5D of Prunus yedoensis could be guidelines for root-ball diameters at the base of trees when planting. However, we concluded that 4D∼5D root-ball is the optimum guideline for regrowth when adapting this guideline to all landscape trees with 8∼l0cm diameter at the base.

Measuring the Earth's Size Using the Sun's Altitude and The Responses

  • Chae, Dong-Hyun
    • 대한지구과학교육학회지
    • /
    • 제5권1호
    • /
    • pp.88-94
    • /
    • 2012
  • This study was created to resolve the problems embedded in the formal measuring experiments to determine the earth's size in the current curriculum, to develop an updated measuring experiment to determine the earth's size and to establish its effect. For this study, pre-service elementary teachers, who had attempted the experiment of measuring the size of the earth when they were in middle school, performed the experiments in the existing national curriculum, and their responses, collected through in-depth interviews, were examined. To begin with, the pre-service elementary teachers conducted the experiment of measuring the earth size and they recorded the problems while performing it. At the end, an in-depth interview was administered. Based on the problems, an updated measuring experiment to determine the earth's size was suggested to be applied to the same contents and be analyzed through the in-depth interviews. Common themes which were mutually categorized and analyzed by the two researchers were obtained based on the records produced while conducting the experiment and the in-depth interview data. The teachers mentioned that the experiments for measuring the size of the earth in the current curriculum gave rise to difficulties in measuring precisely the angles between the string and the post. Also, there has been a scientific contradiction that solar altitudes were increased in a high latitude region, instead of decreased. For this reason, an alternative method has been developed to measure the earth's size using the distance and the solar altitude difference of two places. The teachers all agreed that by using the updated measuring experiment, they can acquire more precise measurements and it is easier, faster and consequently more effective than the existing methods. Through the results of this study, I suggest that the newly developed experiment by the researchers can overhaul the problems of the current experiments and it can be an effective alternative to the current experiment.

The Effect of Text Information Frame Ratio and Font Size on the Text Readability of Circle Smartwatch

  • Park, Seungtaek;Park, Jaekyu;Choe, Jaeho;Jung, Eui S.
    • 대한인간공학회지
    • /
    • 제33권6호
    • /
    • pp.499-513
    • /
    • 2014
  • Objective: The objective of this study was to examine frame ratio of text information and font size in the circle smartwatch. Background: Recently, electronic manufacturers try to develop the original metaphor of traditional wrist watch (circle) in terms of smartwatch. They endeavor to break the square display in order to improve emotional customer satisfaction. Method: The experiments examined twenty level of text information design, combinations of four frame ratios (1:1, 4:3, 16:9, 21:9) and five font sizes (6pt, 7pt, 8pt, 9pt, 10pt). Nineteen participants volunteered for the experiment. Dependent variables were WPM (Words per Minute), reading preference, design preference and total preference. Furthermore, small circle display was made by using circle display data (1.3inch), which was exhibited in IFA (International Funkausstellung) 2014. Results: As a result, ANOVA (Analysis of Variance) revealed that WPM, and task time preference affect the specific frame ratio and font size. Results of ANOVA for reading preference, design preference, total preference were grouped by post-analysis LSD (Least Significant Difference). Among users, display ratio (16:9, 21:9), and font size (9pt) were preferred. In conclusion, 16:9 display ratio and 9pt are adaptable for text information in 1.3inch circle display. Conclusion: From the study, it is shown that 16:9 display ratio and 9pt size are more adaptable for text information in 1.3inch circle display than others. It is mainly due to the fact that the order of frame ratio and font size may affect the usability of reading long text information in a small circle display. Therefore, when developers design a circle display, the square frame ratio and font size are required to be considered according to circle size. Application: The 16:9 display ratio and 9pt font size may be utilized as a text information frame in the circle display design guideline for smartwatch.

숲 체험 활동이 유아의 사회성 발달의 효과에 관한 메타분석 (A Meta-Analysis on Effects of Infant's Sociality Development in Forest Experience Activities)

  • 김찬우;박덕병
    • 농촌지도와개발
    • /
    • 제29권4호
    • /
    • pp.225-250
    • /
    • 2022
  • This study aims to examine the effects of infant's social development forest experience activities through meta-analysis. The final nine studies(total of 165 in the experimental group and 159 in the control group) were selected as a method of systematic review. Meta-analysis on overall effect size estimation, chi-square test, significance analysis, publication bias analysis, and subgroup analysis was performed using the R program. The overall effect size of 9 studies was 1.59, indicating a large effect size. As a result of subgroup analysis of the sub-factors of sociality, autonomy showed the largest effect size at 1.47, the adjusted effect size of cooperation was 1.34, the effect size adjusted for peer interaction was 1.29, and the adjusted effect size for perspective-taking ability was 0.97. All were found to have a statistically significant effect. To analyze the moderating effect, a meta-regression analysis was conducted on the participation period(4, 5~6, 7~8weeks), the number of sessions(6~10, 11~15, 16~20), the frequency per week(1, 2, 5), and the participation time(40, 60, 90, 120, 150min), but there was no statistical difference. Although not statistically significant, the effect size was larger when the participation period was 4 weeks, the number of sessions was 16 to 20, the frequency was 2 times per week, and the participation time was 40 minutes. This results can be usefully utilized by policy makers and forest commentators related to the vitalization of forest education through forest experience activities.

수술 전 검사 시기에 따른 자기공명영상과 관절경상의 회전근 개 파열의 크기 비교 (Comparison of Preoperative Magnetic Resonance Image (MRI) and Arthroscopic Rotator Cuff Tear Size according to Timing of MRI)

  • 박창민;채승범;최창혁
    • Clinics in Shoulder and Elbow
    • /
    • 제16권1호
    • /
    • pp.10-16
    • /
    • 2013
  • 목적: 회전근 개 파열 환자에서 수술 전 시행한 자기 공명 영상 검사를 수술까지 경과되는 시간을 기준으로 분류하고 수술 시 관절경상의 회전근 개 파열의 크기와 비교하여 자기 공명 영상 재검사의 필요 여부를 알아 보고자 하였다. 대상 및 방법: 110예에서 수술 전 시행한 자기 공명 영상 검사를 시기에 따라 수술 전 1개월(A군, 평균 16일, 44예), 1개월~6개월(B군, 평균 91일, 41예), 6개월~1년(C군, 평균 230일, 25예)으로 분류하여 관절경하 회전근 개 파열의 전후방 크기(길이) 및 내측 퇴축의 크기(너비)를 비교하였다. 결과: A, B, C군에서 관절경상 파열의 크기가 더 크게 나타났으며 A군에서 시행한 자기 공명 영상과 관절경의 회전근개 파열의 크기 차이는 길이와 너비 각각 3.6(${\pm}1.2$) mm, 0.6(${\pm}0.4$) mm, B군에서는 4.2(${\pm}1.7$) mm, 2.4(${\pm}1.1$) mm, C군에서 4.5(${\pm}2.1$) mm, 3.0(${\pm}1.5$) mm의 차이를 보였다. 각 군간 파열의 길이 및 너비는 자기 공명 영상 검사와 수술까지의 시간이 길어질수록 증가하는 양상을 보였으나 통계학적 유의성은 없었다. 결론: 수술 1년 이내에 시행한 자기 공명 영상 검사상 회전근 개 파열의 크기는 관절경 소견과 유사하였으며 수술 시 추가적인 자기 공명 영상 검사는 필요 없을 것으로 생각된다.

흉부 방사선검사 영상을 이용한 한국인 정상 여성의 임신기와 비 임신기 심장크기와 심흉비 비교 (Comparison of Cardiac Size and Cardiac Thoracic Ratio in Pregnant and Non-pregnant Women of Normal Korean Women Using Chest X-ray)

  • 주영철;김규형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.223-229
    • /
    • 2018
  • The purpose of this study is to present the reference values for cardiac size and cardiothoracic ratio change, normal range and diagnosis of cardiovascular disease in pregnancy and non pregnancy of normal Korean women using chest X-ray. The subjects of this study were 58 women, who were read as normal by chest radiologist, had chest radiography taken on both last month of pregnancy, pre-pregnancy and within 2 years following delivery. In this study, we defined the last month of pregnancy as pregnancy and before or post pregnancy as non-pregnancy. CS and CTR were measured by two radiological technologist who had clinical experience more ten years with Danzer's method. Statistical methods were paired t-test and one-way ANOVA. Significance level ${\alpha}$ was 0.05 and p-value 0.05 or less was statistically significant. For pregnancy, the mean of left and right cardiac size was $40.11{\pm}8.73mm$ and $89.51{\pm}11.9mm$, CS was $128.60{\pm}13.15mm$, CTR was $44.51{\pm}4.21%$. In non pregnancy, $36.50{\pm}8.18mm$ and $77.68{\pm}13.1mm$. CS and CTR were $114.18{\pm}14.28mm$ and $42.03{\pm}4.04%$. Both pregnancy and non pregnancy, the difference of the mean value in left and right cardiac size, CS and CTR were statistically significant (p<0.01). but comparing mean on age, height and weight, the difference of the mean value between groups was not (p>0.05). In the result of this study, the mean size of CS increased by 12.6% in pregnancy($128.60{\pm}13.15mm$) compared to the non pregnancy($114.18{\pm}14.28mm$), and increased by 9.8% in the right side of the heart and 15.2% in the left side. The mean size of CTR increased about 5.9% in pregnancy ($44.5{\pm}4.21%$) compared to non pregnancy($42.03{\pm}4.04%$).

Surgical indication analysis according to bony defect size in pediatric orbital wall fractures

  • Kim, Seung Hyun;Choi, Jun Ho;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • 대한두개안면성형외과학회지
    • /
    • 제21권5호
    • /
    • pp.276-282
    • /
    • 2020
  • Background: Orbital fractures are the most common pediatric facial fractures. Treatment is conservative due to the anatomical differences that make children more resilient to severe displacement or orbital volume change than adults. Although rarely, extensive fractures may result in enophthalmos, causing cosmetic problems. We aimed to establish criteria for extensive fractures that may result in enophthalmos. Methods: We retrospectively reviewed the charts of patients aged 0-15 years diagnosed with orbital fractures in our hospital from January 2010 to February 2019. Computed tomography images were used to classify the fractures into linear, trapdoor, and open-door types, and to estimate the defect size. Data on enophthalmos severity (Hertel exophthalmometry results) and fracture pattern and size at the time of injury were obtained from patients who did not undergo surgery during the follow-up and were used to identify the surgical indications for pediatric orbital fractures. Results: A total of 305 pediatric patients with pure orbital fractures were included-257 males (84.3%), 48 females (15.7%); mean age, 12.01±2.99 years. The defect size (p=0.002) and fracture type (p=0.017) were identified as the variables affecting the enophthalmometric difference between the eyes of non-operated patients. In the linear regression analysis, the variable affecting the fracture size was open-door type fracture (p<0.001). Pearson's correlation analysis demonstrated a positive correlation between the enophthalmometric difference and the bony defect size (p=0.003). Using receiver operating characteristic curve analysis, a cutoff value of 1.81 ㎠ was obtained (sensitivity, 0.543; specificity, 0.724; p=0.002). Conclusion: The incidence of enophthalmos in pediatric pure orbital fractures was found to increase with fracture size, with an even higher incidence when open-door type fracture was a cofactor. In clinical settings, pediatric orbital fractures larger than 1.81 ㎠ may be considered as extensive fractures that can result in enophthalmos and consequent cosmetic problems.

골격성 III급 부정교합자의 설골 위치와 기도에 대한 평가 (Evaluation of hyoid bone position and airway size in Class III malocclusion)

  • 손우성;최양숙
    • 대한치과교정학회지
    • /
    • 제26권3호
    • /
    • pp.247-254
    • /
    • 1996
  • 골격성 III급 부정교합자의 설골 위치와 기도를 평가하고 이들 사이의 상관관계를 알아보기 위해 부산대학교병원 치과교정과에 내원한 16세 이상의 환자 47명과 치과대학에 재학중인 학생 44명을 대상으로 측모 두부방사선규격사진을 촬영하고 설골의 위치에 대한 전후방적, 수직적 거리 및 각도와 기도의 크기, 하악의 위치에 대해 통계적으로 분석하여 다음과 같은 결론을 얻었다. 1. S-APH, A-APH, N-APH, LAH-PBR, AA-PNS, PNS-ad는 I급 부정교합군과 III급 부정교합군 사이 에 유의한 차이를 보였다. 2. 설골은 III급 부정교합군에서 더 전방에 위치하였으며 경조직 기도 크기는 III급 부정교합군에서 I급 부정 교합군보다 더 작게 나타났다. 3. 다수의 계측치, 특히 설골의 수직적 및 각도 계측치와 기도 크기가 남성과 여성에서 유의한 차이를 보였다. 대개 남성에서 여성보다 수치가 크게 나타났다. 4. 설골의 위치와 기도 크기 사이에 유의한 상관관계는 없었으며 하악의 위치와 기도 크기 사이에도 유의한 상관관계는 없었다. 5. S-APH는 W its appraisal과 역상관관계를 보였으며 A-APH, N-APH는 Wits appraisal과 순상관관계를 보였다. 설골의 수직적 계측치는 하안모 고경과 순상관관계를 나타냈다.

  • PDF

근관 성형 전후의 네 가지 전자근관장측정기의 측정 정확성의 비교 (In vitro comparison of measurement accuracy In pre-enlarged and enlarged canals with four apex locators)

  • 성상엽;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.371-377
    • /
    • 2006
  • 이 연구의 목적은 확대하기 전 근관에서 전자근관장 측정 시의 정확성을 평가하고 확대된 근관에서 파일의 크기에 따른 네 가지 전자근관장 측정기의 정확성을 비교하기 위한 것이다. 발치된 치아 10개를 #10파일을 이용하여 치아의 실제길이를 측정하였다 현미경에서 25배 확대 하에 #10 파일이 치근단공을 넘어 해부학적 치근단공에 이를 때까지 전진하여 디지털 캘리퍼로 측정하였다. Root ZX, Bingo 1020, SmarPex, e-Magic Finder를 알지네이트를 이용한 인체 재현 모델을 이용하여 #10 파일로 apex 표시등에서 측정하였다 (S10). #45까지 핸드 파일로 확대한 다음 #10, #40 파일을 이용하여 전자근관장을 측정하였다. 실제 길이와 각각 측정값의 차이를 계산하여 L10, L40으로 정의하고 기계간의 비교는 one-way ANOVA통계처리하고, Scheffe's multiple range test로 사후 검증하였고, 같은 기계 안의 L10, L40은 Student's t-test로 비교하였다. 본 연구의 실험 조건 하에서, 측정값의 정확도가 기계간에 차이를 보였고, 파일의 크기는 측정값의 정확도에 영향을 주지 못하며, e-Magic Finder는 이 실험 조건하에서 다른 기계에 비해 가장 정확하였다.