• Title/Summary/Keyword: size difference

Search Result 5,027, Processing Time 0.034 seconds

A Meta-analysis of the effects of cardiopulmonary resuscitation training (심폐소생술 교육 효과에 대한 메타분석 연구)

  • Yoou, Soon-Kyu;Lee, Ji-Eun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.1
    • /
    • pp.17-44
    • /
    • 2017
  • Purpose: This study aimed to identify the effects of cardiopulmonary resuscitation (CPR) training using a meta-analysis by effect size. Methods: The effect sizes for each variable and the overall effect size for the collected data were identified. The homogeneity verification of the effect size and the difference among the average effect sizes for each mediation variable were determined. Results: The overall average effect size for CPR training was 1.747. Homogeneity verification of the overall effect size was a Q-value of 3716.962, which was statistically significant (p=.000) when${\alpha}=.05$. CPR training showed statistically significant differences depending on age (p=.002), sex (p=.006), number of trainees (p=.000), research design (p=.000), training method (p=.027), and practical training tools (p=.000). Conclusion: CPR training can effectively improve knowledge, skills, and attitudes about CPR. The results of this meta-analysis contribute to the development of more effective educational guidelines for future CPR training and the advancement of the CPR education field.

Physiochemical Properties of Chicken Breast Sausage with Red Ginseng Marc Powder

  • Shin, Sun-Hwa;Choi, Won-Seok
    • Food Science of Animal Resources
    • /
    • v.42 no.3
    • /
    • pp.486-503
    • /
    • 2022
  • This study explored the physiochemical and rheological properties of chicken breast sausages containing red ginseng marc (RGM) which contains useful components but is discarded. When compared to the control group, the use of RGM significantly increased the water holding capacity (WHC) as the particle size increased. As for the change in color value, addition of RGM resulted in an increase in a and b values; as the quantity was increased and particle size decreased, the a and b values increased significantly. The smaller the particle size of RGM, the greater was the radical scavenging activity. According to the results of the measurement of the viscoelasticity of chicken breast sausage containing RGM, the G' and G'' values increased with increasing amounts of RGM and particle size. Neither the addition of RGM nor its amount or particle size had any significant effect on gel formation temperature. The texture profile analysis (TPA) experiment examined the average TPA measurements of each sample under different measurement conditions, and no significant difference between the RGM and control groups were observed. In conclusion, when RGM is used in chicken breast sausages, the WHC, antioxidant capacity, and viscoelastic properties are affected. RGM can possibly be utilized in high value-added processed meat products if its quantity and particle size are altered based on product characteristics.

A study on the characteristics of difference arrow using three-dimensional MT(Magneto-Telluric) modeling (3차원 전도체의 공간적 위치 및 크기에 따른 차이 지시자의 특성 연구)

  • Yang, Jun-Mo;Oh, Seok-Hoon;Lee, Duk-Kee;Kwon, Byung-Doo;Youn, Yong-Hoon
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.4
    • /
    • pp.305-319
    • /
    • 2002
  • The three-dimensional MT(Magneto-Telluric) modeling is performed to examine the validity of difference arrow of GDS(Geomagnetic Depth Sounding) survey, In this paper, we investigate the validity of the difference arrow on three configurations of conductors; which is located 1) at surface, 2) at the deep part and 3) vertically extended f개m surface to the deep part, respectively, For conductors located at surface, the validity of difference arrows is certified in our numerical model when long periods over 40 minutes are used or the distance between sea and conductor is over 150 km. However, for conductors located at the deep part, the validity of difference arrow is dependent on the size of conductors. Further, if the size of conductor is adequately larger than that of our model, we recognize the possibility that the mutual coupling of them influences up to longer periods, Moreover, in case of conductors which is vertically extended from surface to the deer part, the mutual coupling of them is reinforced for all periods, especially for longer periods, so that the validity of difference arrow is considerably in doubt. Therefore, to remove the known conductor effect such as the sea effect from the observed induction arrow, the mutual coupling between them must be examined. The difference arrow that certifies the validity in this way can only provide the Subsurface information based on physical supports.

  • PDF

A Study on Effective Source-Skin Distance using Phantom in Electron Beam Therapy

  • Kim, Min-Tae;Lee, Hae-Kag;Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.15-19
    • /
    • 2014
  • In this study, for 6-20 MeV electron beam energy occurring in a linear accelerator, the authors attempted to investigate the relation between the effective source-skin distance and the relation between the radiation field and the effective source-skin distance. The equipment used included a 6-20 MeV electron beam from a linear accelerator, and the distance was measured by a ionization chamber targeting the solid phantom. The measurement method for the effective source-skin distance according to the size of the radiation field changes the source-skin distance (100, 105, 110, 115 cm) for the electron beam energy (6, 9, 12, 16, 20 MeV). The effective source-skin distance was measured using the method proposed by Faiz Khan, measuring the dose according to each radiation field ($6{\times}6$, $10{\times}10$, $15{\times}150$, $20{\times}20cm^2$) at the maximum dose depth (1.3, 2.05, 2.7, 2.45, 1.8 cm, respectively) of each energy. In addition, the effective source-skin distance when cut-out blocks ($6{\times}6$, $10{\times}10$, $15{\times}15cm^2$) were used and the effective source-skin distance when they were not used, was measured and compared. The research results showed that the effective source-skin distance was increased according to the increase of the radiation field at the same amount of energy. In addition, the minimum distance was 60.4 cm when the 6 MeV electron beams were used with $6{\times}6$ cut-out blocks and the maximum distance was 87.2 cm when the 6 MeV electron beams were used with $20{\times}20$ cut-out blocks; thus, the largest difference between both of these was 26.8 cm. When comparing the before and after the using the $6{\times}6$ cut-out block, the difference between both was 8.2 cm in 6 MeV electron beam energy and was 2.1 cm in 20 MeV. Thus, the results showed that the difference was reduced according to an increase in the energy. In addition, in the comparative experiments performed by changing the size of the cut-out block at 6 MeV, the results showed that the source-skin distance was 8.2 cm when the size of the cut-out block was $6{\times}6$, 2.5 cm when the size of the cut-out block was $10{\times}10$, and 21.4 cm when the size of the cut-out block $15{\times}15$. In conclusion, it is recommended that the actual measurement is used for each energy and radiation field in the clinical dose measurement and for the measurement of the effective source-skin distance using cut-out blocks.

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

A Study of Somatotype Characteristics of Infants and Sizes Specifications of Apparel Products for Infants I (유아(乳兒)의 체형특징(體形特徵)및 의류제품(衣類製品) 치수규격(規格)에 관(關)한 조사(調査) 연구(硏究) I)

  • Kim, Jin;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.5 no.3
    • /
    • pp.85-93
    • /
    • 2001
  • This study was aimed at reviewing the preceding studies regarding infants' physical characteristics and comparatively examining their apparel specifications among countries, and thereupon, surveying the sizes and specifications of each special infant apparel brand in korea, and thereby, providing for the basic data useful to consumers when they choose infants' apparel sizes and specifications, and at the same time to brand makers for effective exchange of information. Thus, domestic special infant's apparel brands were surveyed for their own sizes and specifications, and thereby, the basic data useful to consumers when they choose their infants' apparel sizes and specifications as well as to brand makers when they exchange information among themselves were produced. The results of this study can summarized as follows: As a result of surveying the general trend of the infant apparel brands in korea, it was found that 5 brands had been established before 1990's, and that the remaining 7 ones had emerged during 1990's. When viewed in terms of brands' originality, it was disclosed that 10 brands were korean originals, while 2 brands were foreign ones licensed. On the other hand, as a consequence of surveying the target age groups of each brand, it was found that the targe age groups differed much ranging from 0 to 72 months or more narrowly from 12 to 24 months, which means that the infant age has yet to be defined for all the brands. In the case of the domestic infant-clothing product respect of inner wear, 8 clothing companies are producing the the outside clothing. In the outside clothing, from 6 months to 36 months' infant is the object, and 6m, 12m, 18m, 24m, 30m, 36m appeared with the fact that it produces in 6 sizes. In the case of the f and the g company which has the difference of size control is big, the f company is producing infant clothing for the age 0 to 72 months in 6 size which the difference of the measurement between the size is a lot to be appear, on the other hand, the g company is producing infant clothing for the age 0 to 6 months in 6 size which the difference of the measurement between the size is small to be appear.

  • PDF

A Study on the Nosocomial Infection in One Burn Unit (일 화상 치료실에 입원한 화상환자의 감염실태조사)

  • 김정애
    • Journal of Korean Academy of Nursing
    • /
    • v.17 no.3
    • /
    • pp.227-240
    • /
    • 1987
  • Infection has assumed increased importance as a cause of death among thermally injured individuals. Decreased treatment effectiveness and an increase in mortality are the hallmarks of nosocomial infection. Infection control is a monumental task that must be achieved to reduce mortalities. This was a retrospective study to survey the epidemiological features of nosocomial infections in a burn unit and to identify the possibilities for infection control. During the past 6 year 2 month period from July, 1981 to August, 1987, 306 burn patients were treated in the burn unit of university hospital. Among of these, 290 cases were the subjects of this study. The data were collected from the patients' records after discharge. All data collected were analyzed using percent, x$^2$-test, t-test with SPSS program. The results of this study are summariged as follows: 1) Infection rate was 40%. According to site, there were 67 cases of wound infection, 60 cases of post-operative skin graft infection, 20 cases of septicemia and 20 cases of donor site infection. As far as the burn size was concerned, the infection rate for patients whose burn size ranged 61 to 70%, was shown to be 100%, followed by the infection rate of 93.8%, for patients whose burn size ranged from 41~50%. As far as the period of time over which the infection developed, 5 to 7 days showed the highest frequency. Further infection was the main cause of deaths and complications. 2) Based upon the results obained by comparing the general characteristics, between a hospital infection-group and non-hospital infection group, there was a significant defference according to age, the time of the year when the accident happened, the place of accident or length of hospital-admission. And according to the result obtained by comparing the general characteristics of the burn, there was a significant difference according to burn size, burn depth, burn type, and burn site. And also based upon the result obtained by comparing the two groups according to method of treatment, there was a significant difference according to the use of antibiotics and to the type of wound-treatment, and for the 8 different binds of treatment related to infection, there was a significant difference for all. In conclusion, age, length of hospital-admission, burn size, burn type, burn site, burn depth, type of woundtreatment and the 8 different binds of treatment, which are related to burns, were shown to be the factors which affect the infection rate in burn patients.

  • PDF

Axillary Bud Development and Necrosis for 'Heukgoosul' Grapevine ('흑구슬' 포도의 액아 형성 및 괴사발생)

  • Kwon, Yong-Hee;Kim, Eun-Joo;Park, Seo-Joon;Lee, Han-Chan;Ma, Kyeong-Bok;Park, Hee-Seung
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.382-386
    • /
    • 2011
  • This study aims to identify the cause for low appearance of flowers in 'Heukgoosul' grapevines, and determine basic characteristics of the axillary buds and types of necrosis in order to find out their influence on necrosis. As for $1^{st}$ to $4^{th}$ node, the closer buds were located to cane, the smaller the size of buds became. However, there was no difference in the size of an axillary bud in the upper part of the shoot above the 4th node. The bud necrosis occurrence in the $1^{st}$ node was the highest with 32% while buds in $4^{th}$ to $10^{th}$ node were normal with 84~96%. The size of buds in July was the largest with 6.40 mm, while buds showed no difference from August to October. The bud necrosis and main bud necrosis occurred most frequently in October, however accessory bud necrosis took place from July demonstrating no difference since then. The analysis on the relationship between shoot vigor and necrosis of axillary buds showed that the shoot diameter and internodes' length have no co-relationship with axillary bud necrosis, but there were negative relationship between the size of buds and necrosis occurrence, which was the most related to accessory bud necrosis. Therefore, despite the low occurrence of bud necrosis and healthy buds in 'Heukgoosul' grapevines, there was little appearance of flowers in the grapevines, which was attributable to the necrosis in the first bud. In conclusion, the research suggests spur pruning with three nodes kept intact yield.

Clinical Outcomes of Coil Embolization for Unruptured Intracranial Aneurysms Categorized by Region and Hospital Size : A Nationwide Cohort Study in Korea

  • Bong-Gyu Ryu;Si Un Lee;Hwan Seok Shim;Jeong-Mee Park;Yong Jae Lee;Young-Deok Kim;Tackeun Kim;Seung Pil Ban;Hyoung Soo Byoun;Jae Seung Bang;O-Ki Kwon;Chang Wan Oh
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.6
    • /
    • pp.690-702
    • /
    • 2023
  • Objective : To analyze the outcomes of coil embolization (CE) for unruptured intracranial aneurysm (UIA) according to region and hospital size based on National Health Insurance Service data in South Korea. Methods : The incidence of complications, including intracranial hemorrhage (ICRH) and cerebral infarction (CI), occurring within 3 months and the 1-year mortality rates in UIA patients who underwent CE in 2018 were analyzed. Hospitals were classified as tertiary referral general hospitals (TRGHs), general hospitals (GHs) or semigeneral hospitals (sGHs) according to their size, and the administrative districts of South Korea were divided into 15 regions. Results : In 2018, 8425 (TRGHs, 4438; GHs, 3617; sGHs, 370) CEs were performed for UIAs. Complications occurred in 5.69% of patients seen at TRGHs, 13.48% at GHs, and 20.45% at sGHs. The complication rate in TRGHs was significantly lower than that in GHs (p=0.039) or sGHs (p=0.005), and that in GHs was significantly lower than that in sGHs (p=0.030). The mortality rates in TRGHs, GHs, and sGHs were 0.81%, 2.16%, and 3.92%, respectively, with no significant difference. Despite no significant difference in the mortality rates, the complication rate significantly increased as the number of CE procedures per hospital decreased (p=0.001; rho=-0.635). Among the hospitals where more than 30 CEs were performed for UIAs, the incidence of CIs (p=0.096, rho=-0.205) and the mortality rates (3 months, p=0.048, rho=-0.243; 1 year, p=0.009, rho=-0.315) significantly decreased as the number of CEs that were performed increased and no significant difference in the incidence of post-CE ICRH was observed. Conclusion : The complication rate in patients who underwent CE for UIA increased as the hospital size and physicians' experience in conducting CEs decreased. We recommend nationwide quality control policies CEs for UIAs.

The Evaluation of Predose Counts in the GFR Test Using $^{99m}Tc$-DTPA ($^{99m}Tc$-DTPA를 이용한 사구체 여과율 측정에서 주사 전선량계수치의 평가)

  • Yeon, Joon-Ho;Lee, Hyuk;Chi, Yong-Ki;Kim, Soo-Yung;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.94-100
    • /
    • 2010
  • Purpose: We can evaluate function of kidney by Glomerular Filtration Rate (GFR) test using $^{99m}Tc$-DTPA which is simple. This test is influenced by several parameter such as net syringe count, kidney depth, corrected kidney count, acquisition time and characters of gamma camera. In this study, we evaluated predose count according to matrix size in the GFR test using $^{99m}Tc$-DTPA. Materials and Methods: Gamma camera of Infinia in GE was used, and LEGP collimator, three types of matrix size ($64{\times}64$, $128{\times}128$, $256{\times}256$) and 1.0 of zoom factor were applied. We increased radioactivity concentration from 222 (6), 296 (8), 370 (10), 444 (12) up to 518 MBq (14 mCi) respectively and acquired images according to matrix size at 30 cm distance from detector. Lastly, we evaluated these values and then substituted them for GFR formula. Results: In $64{\times}64$, $128{\times}128$ and $256{\times}256$ of matrix size, counts per second was 26.8, 34.5, 41.5, 49.1 and 55.3 kcps, 25.3, 33.4, 41.0, 48.4 and 54.3 kcps and 25.5, 33.7, 40.8, 48.1 and 54.7 kcps respectively. Total counts for 5 second were 134, 172, 208, 245 and 276 kcounts from $64{\times}64$, 127, 172, 205, 242, 271 kcounts from $128{\times}128$, and 137, 168, 204, 240 and 273 kcounts from $256{\times}256$, and total counts for 60 seconds were 1,503, 1,866, 2,093, 2,280, 2,321 kcounts, 1,511, 1,994, 2,453, 2,890 and 3,244 kcounts, and 1,524, 2,011, 2,439, 2,869 and 3,268 kcounts respectively. It is different from 0 to 30.02 % of percentage difference in $64{\times}64$ of matrix size. But in $128{\times}128$ and $256{\times}256$, it is showed 0.60 and 0.69 % of maximum value each. GFR of percentage difference in $64{\times}64$ represented 6.77% of 222 MBq (6 mCi), 42.89 % of 518 MBq (14 mCi) at 60 seconds respectively. However it is represented 0.60 and 0.63 % each in $128{\times}128$ and $256{\times}256$. Conclusion: There was no big difference in total counts of percentage difference and GFR values acquiring from $128{\times}128$ and $256{\times}256$ of matrix size. But in $64{\times}64$ of matrix size when the total count exceeded 1,500 kcounts, the overflow phenomenon was appeared differently according to predose radioactivity of concentration and acquisition time. Therefore, we must optimize matrix size and net syringe count considering the total count of predose to get accurate GFR results.

  • PDF