• Title/Summary/Keyword: size control

Search Result 7,241, Processing Time 0.033 seconds

Effect of Power Control Step Size on the Performance of the SIC Scheme in Power-Controlled DS/CDMA Systems

  • Lee, Chiho;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1701-1704
    • /
    • 2002
  • In this paper, we investigate the effect of power control step size on the performance of the SIC scheme in DS/CDMA systems. We investigate the average power control iteration and its standard deviation and evaluate the outage performance for several different values of power control step size. Because the SIC scheme requires fine control in the received signal power, the better outage performance is obtained fer the smaller power control step size. However, the smaller power control step size requires larger amount of power control iteration in order to make the power control converge to the steady state. Under the simulated environment, the proper power control step size is about 0.3-0.4dB from both convergence speed of power control algorithm and outage performance points of view.

  • PDF

The MPPT Control oh Photovoltaic System using FVSS-PO Method (FVSS-PO를 이용한 태양광 발전시스템의 MPPT 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.20-26
    • /
    • 2013
  • This paper proposes the maximum power point tracking(MPPT) control of photovoltaic system using fuzzy based variable step size perturbation & observation(FVSS-PO) method. Conventional PO and incremental conductance(IC)MPPT control algorithm generally uses fixed step size. A small fixed step size will cause the tracking speed to decrease and tracking accuracy of the MPP will decrease due to large fixed step size. Therefore, the fixed step size can't be satisfying both the tracking speed and the tracking accuracy. This paper proposes FVSS-PO MPPT algorithm that adjusts automatically step size of PO by fuzzy control according to operating conditions. The validity of MPPT algorithm proposed in this paper prove through compare with conventional PO MPPT algorithm.

Analysis of Control Performance in Gap Size of MR Damper (MR Damper의 Gap Size에 따른 제어성능 분석)

  • Heo, Gwang Hee;Jeon, Seung Gon;Seo, Sang Gu;Kim, Dae Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.41-50
    • /
    • 2021
  • In this study, the flow path width (Gap Size), which is the flow path of fluid, was selected differently among various factors that determine the Ccontrol Force of MR damper, and the change of Control Force was confirmed accordingly. For this purpose, two MR dampers with a Gap Size of 1.0mm and 1.5mm were fabricated, respectively, and dynamic load experiments were conducted according to changes in applied current and vibration conditions The experimental results showed that the minimum Control Force was 3.2 times higher than 1.5mm in the case of 1.0mm Gap Size, and the maximum Control Force was 2.3 times higher than 1.5mm in the case of 1.0mm Gap Size. In addition, the increased width of the Control Force according to applied current was 34N for Gap Size 1.0mm, and 12.7N for Gap Size 1.5mm. As the gap Size increased, the overall Control Force and the increase in the Control Force by the applied current decreased. Next, the dynamic range, which is a performance evaluation index of the semi-active Control device, was 2.3 on average under 1.0mm condition and 2.8 on average under 1.5mm condition, confirming the possibility of utilization as a semi-active Control device.

Improving the performance of PV system using the N-IC MPPT methods (N-IC MPPT방법을 이용한 태양광 발전시스템의 성능개선)

  • Seo, Tae-Young;Ko, Jae-Sub;Kang, Sung-Min;Kim, Yu-Tak;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.958-959
    • /
    • 2015
  • This paper proposes adaptive incremental conductance(A-IC) algorithm for maximum power point tracking(MPPT) control of photovoltaic. Conventional Perturbation & Observation(PO) and IC MPPT control algorithm generally uses fixed step size. A small fixed step size will cause the tracking speed to decrease and tracking accuracy of the MPP will decrease due to large fixed step size. Therefore, this paper proposes N-IC MPPT algorithm that adjust automatically step size according to operating conditions. To improve tracking speed and accuracy, when operating point is far from maximum power point(MPP), step size uses maximum value and when operating point is near from MPP, step size uses variable step size that adjust according to slope of P-V curve. The validity of MPPT algorithm proposed in this paper prove through compare with conventional IC MPPT algorithm.

  • PDF

Development of Control System of Twin-Fluid Nozzles for Controlling Spraying Rate and Droplet Size (이류체노즐을 이용한 분무량과 분무입경 제어시스템 개발)

  • 이중용;안형철;정창주
    • Journal of Biosystems Engineering
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • In precision chemical application increment of biological efficacy with less chemical is the virtue. spraying rate and droplet size is closely related to biological efficacy. this study was performed to develope a spray-control-system that could control spraying rate and droplet size independently. Twin-fluid nozzles were selected and tested to certify if the nozzles were suitable for the objective of this study. Characteritics of the nozzles i.e., spraying rte and droplet size change u8nder the changes of spraying pressure and air pressure were statistically modeled. The model had I to 1 matching property between dependent variables and independent variables. Using the property and the model, inverse relationship could be determined between variables. A feedback spray control system was developed and tested with predetermined error of 5 % in pressure. The system showed 4 % error in spraying rate and 9 % error in droplets size. Performance of the system could be upgraded by fine tuning but, in practical sense keeping air pressure in the field sprayer was the bottle neck of commercialization of the spray system.

  • PDF

Design of a Curtailed-SPRT Control Chart (단축-축차관리도의 설계)

  • Chang, Young-Soon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.34 no.1
    • /
    • pp.29-37
    • /
    • 2009
  • This paper proposes a curtailed-sequential probability ratio test (SPRT) control chart. For using the conventional SPRT control chart, the number of items inspected in a sampling point should have no restriction since items in a sampling point are inspected one by one until an SPRT Is terminated. The number of observations taken in a sampling point, however, has an upper bound since sampling and testing of an item is time-consuming or expensive. When the sample size reaches the upper bound without evidence of an in-control or out-of-control state of a process, the proposed chart makes a decision using the sample mean of all observations taken in a sampling point. The properties of the Proposed chart are obtained by a Markov chain approach and the performance of the chart is compared with fixed sample size (FSS) and variable sample size (VSS) control charts. A comparative study shows that the proposed chart performs better than VSS control charts as well as conventional FSS control charts.

Formation and Size Control of Polydiacetylene Sensor Liposome Using Hydrodynamic Focusing (유체집속효과를 이용한 폴리다이아세틸렌 센서 생성 및 크기 제어)

  • Kim, Gang-June;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2688-2691
    • /
    • 2008
  • This study addresses a microfluidic method to uniformly form diacetylene (DA) liposomes and control their size. DA liposomes are biochemical sensor materials with a unique property such that when they are polymerized to polydiacetylene (PDA) they exhibit non-fluorescent blue to fluorescent red phase transition upon chemical or thermal stress. The liposome size and distribution are important because they significantly affect the phase transition. So far, DA Liposomes, have been prepared by mixing of bulk phases leading to heterogeneous, polydisperse distribution in size. Therefore, additional post-processes are required such as sonication or membrane extrusion to obtain an appropriate size of liposomes. Here, we report a novel strategy using a microfluidic chip and hydrodynamic focusing to form DA liposomes and control their size. Preliminary results obtained by scanning electron microscope (SEM) and dynamic light scattering (DLS) show that the microfluidic strategy generates more monodispersed liposomes than a bulk method.

  • PDF

Sample Size and Statistical Power Calculation in Genetic Association Studies

  • Hong, Eun-Pyo;Park, Ji-Wan
    • Genomics & Informatics
    • /
    • v.10 no.2
    • /
    • pp.117-122
    • /
    • 2012
  • A sample size with sufficient statistical power is critical to the success of genetic association studies to detect causal genes of human complex diseases. Genome-wide association studies require much larger sample sizes to achieve an adequate statistical power. We estimated the statistical power with increasing numbers of markers analyzed and compared the sample sizes that were required in case-control studies and case-parent studies. We computed the effective sample size and statistical power using Genetic Power Calculator. An analysis using a larger number of markers requires a larger sample size. Testing a single-nucleotide polymorphism (SNP) marker requires 248 cases, while testing 500,000 SNPs and 1 million markers requires 1,206 cases and 1,255 cases, respectively, under the assumption of an odds ratio of 2, 5% disease prevalence, 5% minor allele frequency, complete linkage disequilibrium (LD), 1:1 case/control ratio, and a 5% error rate in an allelic test. Under a dominant model, a smaller sample size is required to achieve 80% power than other genetic models. We found that a much lower sample size was required with a strong effect size, common SNP, and increased LD. In addition, studying a common disease in a case-control study of a 1:4 case-control ratio is one way to achieve higher statistical power. We also found that case-parent studies require more samples than case-control studies. Although we have not covered all plausible cases in study design, the estimates of sample size and statistical power computed under various assumptions in this study may be useful to determine the sample size in designing a population-based genetic association study.

Detection of Changes of the Population Fraction Nonconforming in the p Control Chart (p관리도의 불량률의 변화 탐지)

  • Chang, Kyung;yang, Moon-Hee
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.3
    • /
    • pp.74-85
    • /
    • 1997
  • In this paper we calculate the subgroup size necessary for detecting the change of percent defective with several detection probabilities for orginal population fraction nonconforming p, changed population fraction nonconforming $p^*$, and the ratio k=$p^*$/p in the usage of p control charts. From our calculation we can know the error level of normal a, pp.oximation in detection probability calculation and recommend the subgroup size with lower error levels of normal a, pp.oximation, and then we show the reasonable subgroup size necessary for p, $p^*$, k, and the detection probability of the change of fraction nonconforming in a process. The information that we here show in tables will be useful when p control chart users decide the subgroup size in the p control chart users decide the subgroup size in the p control chart.

  • PDF

A Study on Smoke Movement by Using Large Eddy Simulation II. Smoke Control Systems and Opening Size (대와류모사를 이용한 연기이동의 연구 II. 제연방식과 개구부의 크기)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.34-38
    • /
    • 2003
  • The large eddy simulation based Fire Dynamics Simulator was utilized to investigate the effects of the size of an opening on smoke removal performance for the three smoke control systems-ventilation purge, and extraction. Three different opening sizes, $r_A$=1, 2, and 3 were investigated while the flow rate remained 0.75 $m^3/s$ at the inlet or outlet depending on the systems. Increase of the opening size did not give a significant difference in the smoke removal rate for the three smoke control systems, though the increasing opening size slightly improved smoke removal. The extraction system was shown the best smoke control system, and the purge system yielded low performance compared to the other two systems for all the different opening sizes.