DOI QR코드

DOI QR Code

Analysis of Control Performance in Gap Size of MR Damper

MR Damper의 Gap Size에 따른 제어성능 분석

  • 허광희 (건양대학교, 해외건설플랜트학과) ;
  • 전승곤 (충남도립대학교, 건설정보학과) ;
  • 서상구 (충남도립대학교, 건설정보학과) ;
  • 김대혁 (건양대학교, 재난안전소방학과)
  • Received : 2020.12.07
  • Accepted : 2021.02.02
  • Published : 2021.02.28

Abstract

In this study, the flow path width (Gap Size), which is the flow path of fluid, was selected differently among various factors that determine the Ccontrol Force of MR damper, and the change of Control Force was confirmed accordingly. For this purpose, two MR dampers with a Gap Size of 1.0mm and 1.5mm were fabricated, respectively, and dynamic load experiments were conducted according to changes in applied current and vibration conditions The experimental results showed that the minimum Control Force was 3.2 times higher than 1.5mm in the case of 1.0mm Gap Size, and the maximum Control Force was 2.3 times higher than 1.5mm in the case of 1.0mm Gap Size. In addition, the increased width of the Control Force according to applied current was 34N for Gap Size 1.0mm, and 12.7N for Gap Size 1.5mm. As the gap Size increased, the overall Control Force and the increase in the Control Force by the applied current decreased. Next, the dynamic range, which is a performance evaluation index of the semi-active Control device, was 2.3 on average under 1.0mm condition and 2.8 on average under 1.5mm condition, confirming the possibility of utilization as a semi-active Control device.

본 연구에서는 MR Damper의 제어력을 결정하는 다양한 요인들 중, 유로폭(Gap Size)을 다르게 선정하여 그에 따른 제어력의 변화를 확인하였다. 이를 위해 Gap Size 1.0mm, 1.5mm인 MR Damper 두 대를 제작하고 인가전류와 가진조건을 정하였으며 그에 따른 동하중 실험을 수행하였다. 실험결과 최소제어력은 Gap Size 1.0mm 조건이 Gap Size 1.5mm 조건보다 3.2배 높았으며 최대제어력은 Gap Size 1.0mm 조건이 Gap Size 1.5mm 조건보다 2.3배 높았다. 또한, 인가전류에 따른 제어력의 증가폭은 Gap Size 1.0mm일 때 34N, Gap Size 1.5mm일 때 12.7N으로 나타났다. Gap Size가 커질수록 전체 제어력과 인가전류에 따른 제어력의 증가는 감소하였다. 두 개의 MR Damper의 동적범위를 확인해 본 결과 Gap Size 1.0mm일 때 평균 2.3, Gap Size 1.5mm일 때 평균 2.8인 것을 볼 때 두 MR Damper의 준능동제어장치로써 사용가능성을 확인하였다.

Keywords

References

  1. Rabinow, J. (1948), The magnetic fluid clutch, Electrical Engineering, 67(12), 1167-1167. https://doi.org/10.1109/EE.1948.6444497
  2. Park JH, Ham YB, (2008), Basic Characteristic of MR Fluid and Its Application Journal of Drive and Control, 5(3), 9, 9-14
  3. Yang G, Spencer Jr. BF, Carlson JD, Sain MK. (2002), Large-scale MR fluid dampers: modeling and dynamic performance considerations. Engineering Structures, 24(3), 309-233. https://doi.org/10.1016/S0141-0296(01)00097-9
  4. Lee KH, Kim GC, Lee ES. (2007), A Control Method of Semi-active TMD for Vibration Control. Journal of the Korean Association for Spatial Structures, 7(2), 53-61
  5. Heo GH, Lee G, Lee WS, Lee DG. (2005), Designing a Smart Damping System to Mitigate Structure Vibration: Part 2. Experimental Approval of Unified Lyapunov Control Algorithm. Smart Structures and Material 12th SPIE Annual International Symposium. March, 5757(1), 587-593.
  6. Heo GH, Jeon SG. (2013), Characteristics and Dynamic Modeling of MR Damper for Semi-active Vibration Control Journal of the Korea Institute for Structural Maintenance and Inspection. Nov; 17(6), 72-80.
  7. Heo GH, Jeon SG. (2018), Control Performance Evaluation of cylinder Type Damper using SMG Fluid. Korean Society for Structural Maintenance and Inspection 2018 Spring Conference, Apr; 141-142.
  8. Kim HS, Roschke PN. (2005), Numerical Study of Hybrid Base-isolator with Magnetorheological Damper and Friction Pendulum System. Journal of the Earthquake Engineering Society of Korea, 9(2), 7-15. https://doi.org/10.5000/EESK.2005.9.2.007
  9. Datta TK. (2003), A State-of-Art Review on Active Control of Structures. ISET Journal of Earthquake Technology. Paper Mar; 40(1), 1-17.
  10. Heo GH, Jeon JR, Jeon SG. (2016), Real-time Semi-active Vibration Control in Cable-stayed Bridges by Shear-type MR damper and Clipped-optimal Control Algorithm. Journal of the Earthquake Engineering Society of Korea, 20(2), 113-123. https://doi.org/10.5000/EESK.2016.20.2.113
  11. Yang G, Spencer Jr BF, Carlson JD, Sain MK,(2002), "Large-scale MR Fluid dampers: modeling and dynamic performance considerations, Engineering Structures, 24(3), 309-323. https://doi.org/10.1016/S0141-0296(01)00097-9
  12. Sodeyama H, Suzuki K, Sunakoda K, (2004), Development of Large Capacity Semi-Active Seismic Damper Using Magneto-Rheological Fluid, Transactions of the ASME, Journal of Pressure Vessel Technology, Feb, 126(1), 105-109. https://doi.org/10.1115/1.1634587
  13. F.Weber, (2014), Semi-active vibration absorber based on real-time controlled MR damper, Mechanical Systems and Signal Processing, 46(2), Jun., 272-288. https://doi.org/10.1016/j.ymssp.2014.01.017
  14. Jung Woo Sohn, Jong-Seok Oh, Seung-Bok Choi, (2015), Damping Force Characteristics of MR Damper with Additional Flow Path, Transactions of the Korean Society for Noise and Vibration Engineering, 25(6), June, 426-431. https://doi.org/10.5050/KSNVE.2015.25.6.426
  15. Stanway R., Sproston J.L., and Stevens N.G. (1987), Non-linear Modeling of an Elcetro-rheological Vibration Damper, Journal of Electrostatics, 20(2), 167-184. https://doi.org/10.1016/0304-3886(87)90056-8
  16. Sodeyama H, Sunakoda K, Sunakoda K.,, Fujitani H., Soda S, Iwata N, Hata K. (2003), Dynamic Test and Simulation of Magneto-Rheological Dampers, Computer-Aided Civil and Intrastructure Engineering, 18(1), 45-57. https://doi.org/10.1111/1467-8667.t01-1-00298
  17. LORD Technical Data, MR Damper RD-8040-1, 2009 LORD Corporation OD DS7016 (Rev.0 6/09).
  18. Heo GH, Jeon SG, (2017) Real-time Vibration Control of Cable Bridges using a Shear-type MR Damper-Focusing on Power Model and Lyapunov Control, EESK J Earthquake Eng, 21(5), 215-226.