• 제목/요약/키워드: situ measurement

검색결과 613건 처리시간 0.031초

음향 실험 및 모델 기법을 이용한 도루묵 (Arctoscopus japonicus)의 음향산란반사강도 특성 (Target strength characteristics of sailfin sandfish (Arctoscopus japonicus) using ex situ experiment and acoustic model)

  • 이형빈;이경훈;윤은아;황강석;최정화;박태건
    • 수산해양기술연구
    • /
    • 제51권3호
    • /
    • pp.405-413
    • /
    • 2015
  • Acoustic target strength (TS) measurement and theoretical acoustic scattering models were applied to estimate the TS for assessing the fish biomass. TS measurement was made of ex situ sailfin sandfish Arctoscopus japonicus at 70 and 120 kHz, and then compared to backscatter model prediction. The live sandfish was tethered in seawater using monofilament lines. Measurements were made versus incidence angle, $-50^{\circ}$ to $50^{\circ}$ relative to dorsal aspect directions. Distorted wave Born approximation (DWBA) model was used to calculated TS pattern. The TS values of sandfish (body length: 16.2 cm) at 70 and 120 kHz were -66.94 dB and -64.45 dB, respectively, and were about 20 dB lower than TS of other fishes in Korea waters. These TS levels were distributed within the range of the theoretical TS. Ex situ measurement and theoretical TS may be applied to improve acoustical detection and biomass estimation of the sandfish, and is necessary to measure with various lengths.

연료전지용 고분자전해질막의 실시간 수소 투과도 측정법 연구 (The Study on In-situ Measurement of Hydrogen Permeability through Polymer Electrolyte Membranes for Fuel Cells)

  • 임윤재;이창현
    • 멤브레인
    • /
    • 제26권2호
    • /
    • pp.141-145
    • /
    • 2016
  • 고분자전해질막은 전극 이외에 전기 화학 연료전지의 성능을 결정하는 중요한 요소이다. 고분자전해질막은 가스나 양성자 등의 작은 분자를 선택적으로 수송해야 한다. 고분자전해질막을 투과한 가스는 급속히 전기 화학적 환원을 발생시켜 음극 촉매의 열화를 유발하기 때문에 수소 장벽으로 작동해야 하며 가능한 한 빨리 양성자를 이동시켜야 한다. 지금까지 고분자전해질막의 수소 기체 투과도를 측정하는데 한정된 방법(예 : Constant volume/variable pressure (Time-lag)법)을 사용했다. 그러나 측정의 대부분은 고분자전해질막은 건조된 진공 하에서 이루어진다. 그렇지 않으면 얻어진 수소 투과도는 측정 오차가 커지는 원인이 되기 쉽다. 이 연구에서는 일반적으로 고분자전해질막으로 사용되는 Nafion212의 수소 가스 투과 특성을 온도와 습도가 동시에 제어되는 in-situ 측정 시스템을 이용하여 평가하였다.

기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구 (The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment)

  • 김서훈;김종훈;류승환;정학근;송규동
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구 (In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System)

  • 신영기;양훈철;태춘섭;조수;김영일
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

GMAP 2021 캠페인 기간 용인지역 오존 연직 분포 관측 (The Observation of Ozone Vertical Profile in Yongin, Korea During the GMAP 2021 Field Campaign)

  • 류호선;구자호;김형규;이나현;이원진;김주완
    • 대기
    • /
    • 제32권3호
    • /
    • pp.247-261
    • /
    • 2022
  • The importance of ozone monitoring has been growing due to the polar ozone depletion and increasing tropospheric ozone concentration over many Asian countries, including South Korea. In-situ measurement of the vertical ozone structure has advantages for ozone research, but observations are not sufficient. In this study, ozonesonde measurements were performed from October to November in Yongin during the GMAP (The GEMS Map of Air Pollution) 2021 campaign. The procedure for ozonesonde preparation and initial analysis of the observed ozone profile are documented. The observed ozone concentrations are in good agreement with previous studies in the troposphere, and they capture the stratospheric ozone distribution as well, including stratosphere-troposphere exchange event. These balloon-borne in situ measurements can contribute to the evaluation of remote sensing measurements such as Geostationary Environment Monitoring Spectrometer (GEMS). This document focuses on providing essential information of ozonesonde preparation and measurement for domestic researchers.

침적식 온라인 굴절계를 이용한 알코올 농도의 측정 (Concentration Measurement of Alcohol Solution Using Immersion-Type On-Line Refractometer)

  • 정옥진;김영한
    • 제어로봇시스템학회논문지
    • /
    • 제9권6호
    • /
    • pp.473-477
    • /
    • 2003
  • An immersion-type on-line refractometer useful for the in-situ measurement of chemical composition and temperature is developed, and its performance is examined by applying the refractometer to known alcohol solution having concentrations between 0 vol. % and 25 vol. %. Because refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for fast and direct measurement. The outcome of composition measurement for the different concentrations of alcohol solution indicates that the device is suitable for the chemical composition measurement by yielding stable and reproducible reading.

In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector

  • Ji, Young-Yong;Lim, Taehyung;Lee, Wanno
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.85-96
    • /
    • 2018
  • Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, $LaBr_3(Ce)$ scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an $LaBr_3(Ce)$ detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an $LaBr_3(Ce)$ detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.

in situ ELISA를 이용한 사람세포거대바이러스의 측정법 개발 (Establishment of Measurement of Human Cytomegalovirus with in situ ELISA)

  • 황응수;김진희;박정규;차창룡
    • 대한바이러스학회지
    • /
    • 제30권2호
    • /
    • pp.125-130
    • /
    • 2000
  • Infection with human cytomegalovirus (HCMV) is of considerable clinical relevance after placental transmission and in immunosuppressed patients such as transplant recipients or patients with AIDS. The rapid detection method of HCMV has been required to overcome the time-consuming methods such as classical plaque assay or other immunological methods. This study was performed to establish the in situ ELISA, in which human lung fibroblasts infected with HCMV were fixed and used directly as antigen in 96 well culture plate. Expressed HCMV antigens were detected with HCMV-specific monoclonal antibodies. This method could detect HCMV dose-dependently upto $3{\times}10^2\;pfu/ml$. Antiviral activity of ganciclovir could be assayed within the known range of effective dose. This result showed that HCMV could be quantitated by in situ ELISA. The chemical, which was selected on the basis of component analysis in natural product, was tested to have the anti-HCMV activity by in situ ELISA, and three among five samples were found to have anti-HCMV activity with the dose-dependent manner. Conclusively in situ ELISA could be useful method for quantitation of HCMV and screening antiviral activity of samples to HCMV.

  • PDF

전자기력 측정과 방향성주파수 응답함수를 이용한 능동 자기베어링 시스템의 운전중 모드시험 및 매개변수 규명 (In-situ modal testing and parameter identification of active magnetic bearing system by magnetic force measurement and the use of directional frequency response functions)

  • 하영호;이종원
    • 대한기계학회논문집A
    • /
    • 제21권7호
    • /
    • pp.1156-1165
    • /
    • 1997
  • Complex modal testing is employed for the in-situ parameter identification of a four-axis active magnetic bearing system while the system is in operation. In the test, magnetic bearings are used as exciters as well as actuators for feedback control. The experimental results show that the directional frequency response function, which is properly defined in the complex domain, is a powerful tool for identification of bearing as well as modal parameters. It is also shown that the position and current stiffnesses can be accurately estimated using the relations between the measured forces, displacements, and currents.

비접촉식 4-전극형 전기용량 센서를 이용한 in situ 정밀측정 (Precise in situ Measurement using Non-Contacting Capacitive Sensor with 4-Electrodes)

  • 이래덕
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.93-98
    • /
    • 1999
  • Non-contacting capacitive sensors, based on principle of the cross capacitor, for measuring small displacement less than 1.95$\pm$0.5 mm have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors, the new sensor is consisted of 4-electrodes which are formed 2 active electrodes and 2 guard electrodes on a sapphire plate with diameter 17mm and thickness 0.7 mm, and are symmetrically situated with constant gap of 0.2 mm among the electrodes. The sensor is evaluated to be correlation coefficient of 0.9987 for the range of 1.95$\pm$0.5 mm and that of 0.9995 for 1.95$\pm$0.25 mm range. This sensor can be used for in situ measurements in the mechanical mirror polishing with precision less than $\pm$1${\mu}{\textrm}{m}$.

  • PDF