• Title/Summary/Keyword: site conditions

Search Result 2,582, Processing Time 0.03 seconds

Factor Analysis on Citizen's Motives to Tree Burial and Choice Conditions to Tree Burial Site (수목장의 동기와 수목장지 선호조건에 대한 요인 분석)

  • Woo, Jae-Wook;Byun, Woo-Hyuk;Park, Won-Kyung;Kim, Min-Soo;Yim, Min-Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.4
    • /
    • pp.639-649
    • /
    • 2011
  • The purpose of this study aimed to analyze factors on motives to tree burial and choice conditions to tree burial site in order to suggest policy direction for the desirable settlement of tree burial. For those purpose, this study performed questionnaire, targeting 522 visitors of funeral hall all around Korea. As the result, the factors of motives to tree burial were extracted as follows: funeral ceremony progressed along with trees, simplicity, memorial site's easy insurance, environmental friendliness and consideration toward descendants. The factors on choice conditions to tree burial sites were extracted as follows: beauty of natural scenery, emotional mood as a memorial site, convenience, stability and economic feasibility. Based on the results of factor analysis, this study suggested policies related to motives to tree burial as follows: develop various types of tree burial sites, develop a funeral ceremony suitable for tree burial, come into wide use of tree burial as a social welfare service, develop tree burial methods capable of many burials, and improve professionalism to manage tree burial system. In addition, this study proposed related choice conditions to tree burial sites as follows: establish natural forest scenery, convert existing graveyards into tree burial sites, select easily accessible places for tree burial sites, form tree burial sites as places for both rest and memory, and reduce using fee of tree burial site.

Analysis on the Users′ Behaviors and Satisfaction on the Actual Conditions of Management in Chiri Mountain National Park (지리산국립공원의 이용자 행태분석과 관리실태에 대한 만족도 조사에 관한 연구)

  • 김광래;진희성;김세천
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.16 no.2
    • /
    • pp.43-57
    • /
    • 1988
  • The purpose of this thesis is to suggest objective basic data for park management proposal through the quantitative analysis of users' behaviors and satisfaction for the actual conditions of management in the Chiri Mountain National Park. For this users' behaviors and socio-economic characteristics have been cross-analyzed. Specifically, it attempts to investigate users' anticipate and degree of satisfaction applied Expectancy Theory by Likert attitude scale. Users'behaviors patterns of each site have been analyzed by the factor analysis algorithm, and each factor scores of sites have been clustered by the cluster method. And also user' satisfaction for the actual conditions of management have been analyzed by using the multiple regression. The major user groups were students and youth groups accompanied by their friends ranging from 3 to 10. The values of user'post occupancy-evaluation for such as rockwall climbing and praying on the mountain of each site showed higher than those of anticipated, but evaluation values of other activities were lower. The user'behaviors of each site have been analyzed five factors by factor analysis algorithm. By using the control method for the number of factors, T.V. has been obtained as 50.58%. The factor score of factor covering the behavior patterns of student and youth yield high EV. and C.V.. On the analysis of cluster using factor score, factor IV in Hwaomsa temple site and Ssanggyesa temple site, factor II, v in Jungsanri Valley site, factor, I, III in Bangmudong valley site and factor I. IV in Baemsagol vallry site showed very high values, respectively. According to the multiple regression analysis, the major variables related to the satisfaction for the actual conditions of vegetation and landscape managements were reservation of groundcover, recovery of artificial injury, the surroundings of camping and temple site. In the park facilities and operation, the major variables related to the satisfaction were conditions of management such amenity facilities as privy, sign board, junk yard, camping site, and guidance of excursion, campaign and preservation of nature.

  • PDF

Geotechnical Site Investigation for Designing of Tidal Power Plant Structures (조력발전 구조물 설계를 위한 지반조사;인천만 지반조사 사례)

  • Oh, Myoung-Hak;Lee, Kwang-Soo;Park, Jin-Soon;Yum, Ki-Dai;Cha, Dai-Wook;Yang, Geun-Hun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.613-616
    • /
    • 2007
  • The main structures that comprise a tidal power plant are turbine structure, sluice structure, tide embankment and gate. Since these structures are founded on seabed ground, an extensive geotechnical site investigation to evaluate the engineering properties of field soils must be conducted prior to design and construction. According to the results of geotechnical site investigation conducted at the planned site for construction of Incheon bay tidal power plant, soft ground generally lie 7 meters below the seabed surface level. This research suggests the reliable and economical design of foundations and ground improvements required for construction of main structures in Incheon bay tidal power plant, with considerations on field conditions.

  • PDF

Dynamic Interaction Modelling between Arctic Offshore Structures and Ice Floe (극지 해양 구조물과 얼음의 동적 모델화)

  • 황철성;김상준
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.1 no.1
    • /
    • pp.87-92
    • /
    • 1989
  • In this study, the nonlinear dynamic model of the systems which include the offshore structure, the surrounding sea water in terms of the added mass, the foundation in terms of frequency independent springs, dashpots, and the floating ice feature with its hydrodynamic added mass, are proposed for the problem of the large ice floes impact. Dynamic Analysis is performed on two site conditions, sand site and silt site, and on two seasons, winter and summer, for various ice floe velocities. As a result of study, Ice floes from energy balenced method is lower than that from dynamic modeling on sand site, and higher than the on silt site.

  • PDF

A Comparative Analysis of the Priority and Evaluation Factors of the Renewable Energy Plan Site by Country (국가별 재생에너지 계획입지제도 절차별 우선순위 및 평가요소 비교 분석)

  • Sung-Hoon, Kim;Hwa-Young, Yoon
    • New & Renewable Energy
    • /
    • v.18 no.4
    • /
    • pp.54-63
    • /
    • 2022
  • This study compared and analyzed major policies and operational processes of countries that introduced the Renewable Energy Plan Site, through literature analysis of published governmet data, and previous research results. The procedures of the Renewable Energy Plan Site were classified into planned location designations, selection of power generation business operators, designation of the business' district and development and evaluating the factors derived for each procedure. Four contries were selected to be compared and analyzed, namely: Denmark, Germany, the United Kingdom and Japan. This was based on the criteria used to introduce and operate the Renewable Energy Plan Site, activate renewable energy supply and check the applicability of Korea's policies. It was analyzed that the priority of the planned location for the procedure was different for each country depending on the conditions there.

Effects of habitat differences on the genetic diversity of Persicaria thunbergii

  • Nam, Bo Eun;Nam, Jong Min;Kim, Jae Geun
    • Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.84-88
    • /
    • 2016
  • To understand the effects of habitat characteristics on the genetic diversity of Persicaria thunbergii, three sites of different environmental conditions in a water system were surveyed. Site A was the closest to the source of the water system, and there was a dam between sites A and B. Site C is located on the lowest downstream in the water system. Vegetation survey of four quadrats at each site was performed, and soil samples were collected for physicochemical analysis. Random amplification of polymorphic DNA (RAPD) analysis of ten P. thunbergii individuals at each site was conducted to calculate population genetic diversity and genetic distance among populations. Soil was sterile sand at site A, whereas loamy soil at sites B and C. A pure stand of P. thunbergii appeared at site A, while other species occurred together (such as Humulus japonicus and Phragmites australis) at sites B (Shannon-Wiener index; $H_B=0.309$) and C ($H_C=0.299$). Similar to the species diversity, genetic diversity (Nei's gene diversity; h) within population of site A ($h_A=0.2381$) was relatively lower than sites B ($h_B=0.2761$) and C ($h_C=0.2618$). However, site C was separated from sites A and B in genetic distance rather than the geographical distance (Nei's genetic distance; A~B, 0.0338; B~C, 0.0685; A~C, 0.0833).

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Optimization of ultra-fast convection polymerase chain reaction conditions for pathogen detection with nucleic acid lateral flow immunoassay

  • Kim, Tae-Hoon;Hwang, Hyun Jin;Kim, Jeong Hee
    • International Journal of Oral Biology
    • /
    • v.44 no.1
    • /
    • pp.8-13
    • /
    • 2019
  • Recently, the importance of on-site detection of pathogens has drawn attention in the field of molecular diagnostics. Unlike in a laboratory environment, on-site detection of pathogens is performed under limited resources. In this study, we tried to optimize the experimental conditions for on-site detection of pathogens using a combination of ultra-fast convection polymerase chain reaction (cPCR), which does not require regular electricity, and nucleic acid lateral flow (NALF) immunoassay. Salmonella species was used as the model pathogen. DNA was amplified within 21 minutes (equivalent to 30 cycles of polymerase chain reaction) using ultra-fast cPCR, and the amplified DNA was detected within approximately 5 minutes using NALF immunoassay with nucleic acid detection (NAD) cassettes. In order to avoid false-positive results with NAD cassettes, we reduced the primer concentration or ultra-fast cPCR run time. For singleplex ultra-fast cPCR, the primer concentration needed to be lowered to $3{\mu}M$ or the run time needed to be reduced to 14 minutes. For duplex ultra-fast cPCR, $2{\mu}M$ of each primer set needed to be used or the run time needed to be reduced to 14 minutes. Under the conditions optimized in this study, the combination of ultra-fast cPCR and NALF immunoassay can be applied to on-site detection of pathogens. The combination can be easily applied to the detection of oral pathogens.

Effect of Materials and Construction Conditions on Shotcrete Quality (숏콘크리트 품질에 미치는 재료 및 시공 조건의 영향)

  • 현석훈;한기석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.227-232
    • /
    • 1994
  • Recently, TBM (Tunnel Boring Machince) method for a tunnel construction in domestic is very promisible due to shorten a constrution period. It is very important to increase the efficiency of the shotcrete for the TBM. The major factors influencing the efficienty of shotcrete are materials, mix disign, constrution conditions and skill of nozzle-man. In this paper, first, optimum synthesize conditions for the shotcrete accelerators was explored and early stiffenting mechanisms also studied. Second, TBM method was applied for a real job site using the optimum conditions obtained from a lab scale experiment.

  • PDF

A Flow Cytometric Study of Autotrophic Picoplankton in the Tropical Eastern Pacific (Flow cytometer를 이용한 열대 동태평양의 독립영양 극미소 플랑크톤 연구)

  • Noh, Jae-Hoon;Yoo, Sin-Jae;Lee, Mi-Jin;Son, Seung-Kyu;Kim, Woong-Seo
    • Ocean and Polar Research
    • /
    • v.26 no.2
    • /
    • pp.273-286
    • /
    • 2004
  • The effects of environmental forcing on autotrophic picoplankton distributional patterns were investigated for convergence ($5^{\circ}N$), divergence ($9^{\circ}N-10^{\circ}30'N$) and oligotrophic ($17^{\circ}N$) sites in the tropical eastern Pacific during 2001 and 2003 KODOS (Korea Deep Ocean Study) cruises. The distributions of picoplankton populations - Prochlorococcus, Synechococcus and picoeukaryotes algae - were determined by flow cytometric analyses. Latitudinal variations in abundance maxima, vertical profiles, integrated abundance (0-150 m), and estimated carbon biomass were contrasted for each site according to three hydrological conditions. Prochlorococcus showed consistently high abundance in the surface mixed layers of all sites at $1\;{\times}\;10^5{\sim}3\;{\times}\;10^5\;cells\;ml^{-1}$ and showed declining abundance below these layers. However, these decreasing rates were not particularly sharp showing considerably high abundance at $1\;{\times}\;10^4\;cells\;ml^{-1}$ or higher even at 100 m depth. Vertical profiles of Synechococcus and picoeukaryotes were generally parallel to each other in all sites. A clear abundance maximum was observed at divergence site at or slightly above the pycnocline depth. Higher abundance was observed at the surface mixed layer for convergence site but a sharp decrease was observed below the pycnocline. However, there was no significant abundance fluctuation with depth at more oligotrophic site ($17^{\circ}N$). Integrated cell abundance of Prochlorococcus was high in the oligotrophic site at $2.17\;{\times}\;10^{13}\;m^{-2}$, and low in the convergence site at $0.88\;{\times}\;10^{13}\;m^{-2}$. However, opposite pattern was observed for Synechococcus and picoeukaryotes where relatively high integrated cell abundance was shown in the convergence site. Estimated carbon biomass of Prochlorococcus contributed 30.4-80.3% of total autotrophic picoplankton carbon showing the highest contribution in the oligotrophic site and the lowest contribution in the convergence site. Synechococcus contribution of total autotrophic picoplantkon carbon biomass was lower than 5.8% for most of sites except the convergence site where Synechococcus contributed 23.2% of picoplankton carbon biomass. Carbon biomass of picoeukaryotes was 18.8-46.4% showing the highest carbon biomass at the convergence site. Overall, Prochlorococcus showed higher cell abundance and carbon biomass and exhibited different reaction to hydrological conditions when compare with the other two major autotrophic picoplankton groups.