• Title/Summary/Keyword: sinusoidal wave

Search Result 298, Processing Time 0.023 seconds

Wall Shear Stress Distribution in the Abdominal Aortic Bifurcation : Influence of wall Motion, Impedance Phase Angle, and non-Newtonian fluid (복부대동맥 분기관에서의 벽면전단응력 분포 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choi J.H.;Kim C.J.;Lee C.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.261-271
    • /
    • 2000
  • The present study investigated flow dynamics of a two-dimensional abdominal aortic bifurcation model under sinusoidal flow conditions considering wall motion. impedance phase angle(time delay between pressure and flow waveforms), and non-Newtonian fluid using computational fluid dynamics. The wall shear stress showed large variations in the bifurcated region and the wall motion reduced amplitude of wall shear stress significantly. As the impedance phase angle was changed to more negative values, the mean wall shear stress (time-averaged) decreased while the amplitude (oscillatory) of wall shear stress increased. At the curvature site on the outer wall where the mean wall shear stress approached zero. influence of the phase angle was relatively large. The mean wall shear stress decreased by $50\%$ in the $-90^{\circ}$ phase angle (flow wave advanced pressure wave by a quarter period) compared to the $0^{\circ}$ phase angle while the amplitude of wall shear stress increased by $15\%$. Therefore, hypertensive patients who tend to have large negative phase angles become more vulnerable to atherosclerosis according to the low and oscillatory shear stress theory because of the reduced mean and the increased oscillatory wall shear stresses. Non-Newtonian characteristics of fluid substantially increased the mean wall shear stress resulting in a less vulnerable state to atherosclerosis.

  • PDF

Evaluation of Dynamic Group Pile Effect in Dry Sand by Centrifuge Model Tests (원심모형 실험을 이용한 건조토 지반에서의 군말뚝 효과 분석)

  • Yoo, Min-Taek;Cha, Se-Hwan;Choi, Jung-In;Han, Jin-Tae;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.1
    • /
    • pp.67-77
    • /
    • 2012
  • In this study, a series of centrifuge shaking-table tests for a $3{\times}3$ group pile and a single pile applied by sinusoidal wave was performed in dry sand for various pile spacings, ranging from three to seven times the pile diameter. A comparison of centrifuge tests of both single pile and group pile showed that the lateral ground response of the group pile was smaller than that of the single pile. In addition, the reduction in subgrade reaction for the group pile increased with decreasing pile spacing. The side piles, that is, the 1st row and 3rd row piles showed identical dynamic p-y behavior and the center pile in the 2nd row caused a lower reduction effect compared with the 1st and 3rd row piles. From the comparison between the p-y curves of the 2nd row piles, it was found that the lateral ground response of the outer pile in the 2nd row was less than that of the center pile in the 2nd row. The p-multipliers for the side piles, for the center pile and for the outer pile ranged from 0.28 to 0.77, from 0.55 to 1.0 and from 0.39 to 0.87, respectively.

Development of Fiber Optic Total Reflected Extrinsic Fabry-Perot Interferometric Sensor for Structural Strain Measurement (구조물의 변형률 측정을 위한 광섬유 TR-EFPI 센서의 개발)

  • Kwon, In-Bum;Choi, Man-Yong;Moon, Hahn-Gue;Kim, Min-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.96-105
    • /
    • 2000
  • Fiber optic TR-EFPI(total reflected extrtinsic Fabry-Perot interferometric) sensor was developed to measure the strain of structures, such as building, bridge, aircraft, etc. It has been difficult to distinguish the increase and decrease of the strain from the conventional fiber optic EFPI sensor because their signals only have a sinusoidal wave pattern related to the change of strain. Also, the absolute strain could not be measured by the simple fiber optic EFPI sensor. In this study, in order to measure the magnitude of strain with the direction of strain, the fiber optic sensor was simply constructed with the total reflected EFPI sensor probe. This probe was manufactured with a single mode fiber and a mirror coated fiber in a silica glass capillary tube. The output signal of this fiber optic TR-EFPT sensor can give the information about the magnitude and the direction of strain. The loading-unloading test was performed by the universal testing machine with alluminum beam specimen to compare the strain from fiber optic TR-EFPI sensor with the value from electrical strain gauge. In the result of this experiment. the strain from fiber optic TR-EFPI sensor had a good agreement with the values from the electrical strain gauge.

  • PDF

Implementation of the BLDC Motor Drive System using PFC converter and DTC (PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.62-70
    • /
    • 2007
  • In this paper, the boost Power Factor Correction(PFC) technique for Direct Torque Control(DTC) of brushless DC motor drive in the constant torque region is implemented on a TMS320F2812DSP. Unlike conventional six-step PWM current control, by properly selecting the inverter voltage space vectors of the two-phase conduction mode from a simple look-up table at a predefined sampling time, the desired quasi-square wave current is obtained, therefore a much faster torque response is achieved compared to conventional current control. Furthermore, to eliminate the low-frequency torque oscillations caused by the non-ideal trapezoidal shape of the actual back-EMF waveform of the BLDC motor, a pre-stored back-EMF versus position look-up table is designed. The duty cycle of the boost converter is determined by a control algorithm based on the input voltage, output voltage which is the dc-link of the BLDC motor drive, and inductor current using average current control method with input voltage feed-forward compensation during each sampling period of the drive system. With the emergence of high-speed digital signal processors(DSPs), both PFC and simple DTC algorithms can be executed during a single sampling period of the BLDC motor drive. In the proposed method, since no PWM algorithm is required for DTC or BLDC motor drive, only one PWM output for the boost converter with 80 kHz switching frequency is used in a TMS320F2812 DSP. The validity and effectiveness of the proposed DTC of BLDC motor drive scheme with PFC are verified through the experimental results. The test results verify that the proposed PFC for DTC of BLDC motor drive improves power factor considerably from 0.77 to as close as 0.9997 with and without load conditions.

In-Vitro Thrombosis Detection of Mechanical Valve using Artificial Neural Network (인공신경망을 이용한 기계식 판막의 생체외 모의 혈전현상 검출)

  • 이혁수;이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.429-438
    • /
    • 1997
  • Mechanical valve is one of the most widely used implantable artificial organs of which the reliability is so important that its failure means the death of patient. Therefore early noninvasive detection is essentially required, though mechanical valve failure with thrombosis is the most common. The objective of this paper is to detect the thrombosis formation by spectral analysis and neural network. Using microphone and amplifier, we measured the sound from the mechanical valve which is attached to the pneumatic ventricular assist device. The sound was sampled by A/D converter(DaqBook 100) and the periodogram is the main algorithm for obtaining spectrum. We made the thrombosis models using pellethane and silicon and they are thrombosis model on the valvular disk, around the sewing ring and fibrous tissue growth across the orifice of valve. The performance of the measurment system was tested firstly using 1 KHz sinusoidal wave. The measurement system detected well 1KHz spectrum as expected. The spectrum of normal and 5 kinds of thrombotic valve were obtained and primary and secondary peak appeared in each spectrum waveform. We find that the secondary peak changes according to the thrombosis model. So to distinguish the secondary peak of normal and thrombotic valve quantatively, 3 layer back propagation neural network, which contains 7, 000 input node, 20 hidden layer and 1 output was employed The trained neural network can distinguish normal and valve with more than 90% probability. As a conclusion, the noninvasive monitoring of implanted mechanical valve is possible by analysing the acoustical spectrum using neural network algorithm and this method will be applied to the performance evaluation of other implantable artificial organs.

  • PDF

Human Safety Assessment for a 4 × 8 Array Antenna Used for Wireless Power Transfer at 2.4 GHz (2.4 GHz의 무선전력전송에 사용되는 4 × 8 배열 안테나에 대한 인체안전성평가)

  • Ju, Young Jun;Kim, Jun Hee;Lee, Yu-ri;Gimm, Yoon-Myoung;Lim, Yong Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.338-341
    • /
    • 2018
  • Wireless Power Transfer(WPT) of array antenna applied to beam-forming techniques enables highly efficient WPT when transmitters and receivers are not contacting and even when they are separated. However, this WPT method is possible to use only when human safety restriction by distance between the transmitters and the receivers is satisfied. In the paper, a $4{\times}8$ array antenna for 2.4 GHz is modeled by simulation, then electric field intensity and 10 gram average head SAR(Specific Absorption Rate) by distance away from the array antenna inputted 1 W of 2.4 GHz sinusoidal wave at each single antenna of the array antenna for 2.4 GHz were obtained. And they were compared with human safety restriction of draft of 2018 ICNIRP(International Commission on Non-Ionizing Radiation Protection) guidelines. As the result, power density of far field derived from the electric field intensity was $33.257W/m^2$, which satisfied with occupational human safety restriction but exceeded public's. In addition, the 10 gram average head SAR exceeded the human safety restriction.

  • PDF

Study on Sound Production and Phonotaxis of Some Fishes and Crabs (몇가지 어류 및 갑각류의 발음과 주음성에 관한 연구)

  • 김상한
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.1
    • /
    • pp.15-36
    • /
    • 1978
  • Underwater sounds of some fishes and crabs were analyzed in the laboratory. The behavioral responses to the playback sounds of their feeding and croaking sound were investigated. The samples used in the experiment were as follows: Nibea albiflora, seriola quinqueradiata, Navodon modestus, Fugu xanthopterus, chrysophrys major, Scylla serrata, Telmessus acutidens, Charybdis japonica, and Portunus trituberculatus. The feeding and croaking sounds of the samples were recorded by a tape recorder through a hydrophone in an anechoic aquarium. The sound intensity level was measured by means of a sound level meter at an anechoic chamber. The frequency, intensity and wave form of various sounds were analyzed with an analyzing system consisting of a 1/3 octave filter set, a high speed level recorder, an amplifier, an octave band analyzer and an oscilloscope. The most successful recording was edited into a sequence of sound track which repeats sound emitting for 5 to 7 seconds after pausing for 5 to 7 seconds. The sequence was then reproduced into an anechoic aquarium through the under water speaker. The experimental anechoic aquarium used for the sample fishes was divided into the four sections with any three screens selected from 40$\times$40mm, 60$\times$60mm, 80$\times$80mm and 100$\times$100mm mushes according to the species of the fishes, besides that for crabs were not sectioned. The results of the investigation are as follows: 1. Of the feeding sound of fish, the frequency of wave from of the sound produced by Nibea albiflora and seriola quinqucradiata was 125~250Hz, that by Navodon modestus 63~125Hz, and that by Fugu xanthopterus 400~500Hz. The pressure level of the feeding sound produced by Nibea albiflora and Seriola quinqueradiata was 56~62db, that by Navodon modestus 57~59db, and that by Fugu xanthopterus 60~64db. 2. Of the croaking sound of Nibea albiflora, the frequency of the sound was 125~250Hz almost equivalent to that of feeding sound, and the pressure level was 62~63db, slightly higher than that of feeding sound. 3. Of the croaking sounds of crabs, the frequency of the sound produced by scylla serrata was 125~250Hz, that by Charybdis japonica and Telmessus acutidens 500~1,000Hz, and that by Portunus trituberculatus 250~500Hz. The pressure level of the croaking sound by Scylla serrata was 68~70db, and that by Charybdis japonica, Telmessus acutidens and Portuens trituberculatus 50~62db. 4. Phonotactic responses of Nibea albiflora and Seriola quinqueradiata to the feeding sounds produced by their own species, the same body length were conspicuous with the phonotactic index of 56~87%, but that of Navodon modestus, Chrysophrys major and Fugu xanthopterus were hardly recognized. 5. Phonotactic responses of the sample fishes to the sinusoidal sound with the frequency range of 50 to 9,000 Hz were observed not conspicuous. 6. Phonotactic responses of Portunus trituberculatus to the croaking sounds produced by their own species was varied in the range of 40~100%, according to the carapace length and the sex.

  • PDF

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.