• Title/Summary/Keyword: single-tooth implant

Search Result 111, Processing Time 0.02 seconds

Axial displacement in single-tooth implant restoration: Case report (임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고)

  • Jeong, Seung-Hoe;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.126-133
    • /
    • 2021
  • Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.

IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES (보철물 조건에 따른 Periotest수치의 실험적 평가)

  • Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

Panoramic radiological study to identify locally displaced maxillary canines in Bangladeshi population

  • Alif, Sheikh Mohammad;Haque, Sejuty;Nimmi, Naima;Ashraf, Ali;Khan, Saeed Hossain;Khan, Mahfujul Haq
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.155-159
    • /
    • 2011
  • Purpose : This study was performed to determine the prevalence of maxillary canine impaction on a basis of a single panoramic radiograph in Bangladeshi population. Materials and Methods : A random sample of seven hundred panoramic radiographs was collected from the patient record of a dental clinic. All the selected panoramic radiographs were taken from January 2009 to August 2010 by a single panoramic radiograph machine with the same exposure time (19 seconds) for all radiographs. One hundred and twenty panoramic radiographs were excluded to minimize the selection bias. In a dim lit room, an observer assessed the radiographs on a standard radiographic light box. The position of the impacted maxillary canine was recorded in line with the longitudinal axis of a tooth using the edge of a metal ruler. Data were subsequently put on SPSS 11.5 software and chi-square (${\chi}^2$) tests were applied to find out the association. Results : Among 580 panoramic radiographs it was found that impacted maxillary canines were present in only 7 (1.2%) radiographs. A statistical significant difference was found between the age of the patients and the vertical position of the impacted canines (p=0.000) and between the age of the patients and the horizontal position of the impacted canines (p=0.003). Conclusion : The prevalence was found to be low compared with the present study from the limitation of panoramic image. Further study needs to include three-dimensional imaging modality.

A radiographic evaluation of graft height changes after maxillary sinus augmentation

  • Kim, Do-Hyung;Ko, Min-Jeong;Lee, Jae-Hong;Jeong, Seoung-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.174-181
    • /
    • 2018
  • Purpose: The aims of the present study were to quantitatively assess graft height changes after sinus lift procedures and to analyze the factors that influenced graft height changes, including the residual bone height before surgery, surgical approach, and tooth type. Methods: A total of 39 maxillary posterior implants placed during a simultaneous sinus lift procedure were evaluated. Panoramic radiographs of all patients were taken immediately after implant installation and at 3 months, 6 months, 1 year, 2 years, and 3 years. To analyze graft height changes over time, we measured the distance between the implant platform and the base of the grafted sinus floor at 3 locations. The radiographs were analyzed by a single examiner. Results: Graft height tended to decrease over time, and a statistically significant difference was observed at 2 years compared to baseline (P<0.05). There was no statistically significant difference in graft height change according to the surgical approach or tooth type. For residual bone height, a statistically significant difference in graft height change was found between those with 4-7 mm of residual bone height and those with ${\geq}7mm$ (P<0.05). Conclusions: Graft height after sinus lift procedures significantly decreased at 2 years compared to baseline after sinus augmentation. Further studies should be done with controlled variables, and prospective studies with 3-dimensional images are needed to clarify the factors that influence graft height changes.

THE STRESS ANALYSIS OF SUPPORTING TISSUE AND IMPLANT ACCORDING TO CROWN RESTORATIVE MATERIALS AND TYPE OF IMPLANT (수복재료와 임플랜트 종류에 따른 임플랜트 및 지지조직의 응력분포)

  • Choi Chang-Hwan;Oh Jong-Suk;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Branemark $system^{(R)}$(Nobel Biocare, Gothenberg, Sweden) and Bicon system(Bicon Dental Implants, Boston, MA). Two dimensional finite element analysis model was made at mandibular first premolar area As a crown materials porcelain, ceromer, ADA type III gold alloy were used. Tests have been performed at 25Kgf vertical load on central fossa of crown portion and at 10Kgf load with $45^{\circ}$ lateral direction on cusp inclination. The displacement and stresses of implant and supporting structures were analyzed to investigate the influence of the crown material and the type of implant systems by finite element analysis. The results were obtained as follows : 1. The type of crown material influenced the stress distribution of superstructure, but did not influence that of the supporting alveolar bone. 2. The stress distribution of ceromer and type III gold alloy and porcelain is similar. 3. Stress under lateral load was about twice higher than that of vertical load in all occlusal restorative materials. 4. In Bicon system, stress concentration is similar in supporting bone area but CerOne system generated about 1.5times eater stress more in superstructure material. 5. In Branemark models, if severe occlusal overload is loaded in superstvucture. gold screw or abutment will be fractured or loosened to buffer the occlusal overload but in Bicon models such buffering effect is not expected, so in Bicon model, load can be concentrated in alveolar bone area.

In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants

  • Garcia-Roncero, Herminio;Caballe-Serrano, Jordi;Cano-Batalla, Jordi;Cabratosa-Termes, Josep;Figueras-Alvarez, Oscar
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.160-165
    • /
    • 2015
  • PURPOSE. In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous$^{(R)}$; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at $30^{\circ}$ in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.

Subjective Symptoms of Peri-Implantitis and Satisfaction according to Prosthesis Methods (임플란트 보철방식에 따른 임플란트 주위염 자각증상 및 만족도)

  • Cha, Ji-Ae;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.175-182
    • /
    • 2017
  • From March 1, 2016 to August 31, 2016, 375 dental implant patients between the ages of 30 and 70 years to evaluate their subjective symptoms and satisfaction according to prosthesis methods. The collected data were analyzed using the chi-square distribution test, t-test, one-way analysis of variance, and multiple logistic regression. Of the patients with subjective symptoms of peri-implantitis, 40.5% reported food impaction, 49.1% reported bleeding, 61.1% reported pain, 61.9% reported halitosis, and the overall satisfaction level with the implants was 3.95 points. In the prosthesis methods, implant-teeth connective group showed the lowest level of the food impaction (21.3%), the pain (35.5%), and the halitosis (36.6%) (p<0.001), and the lowest bleeding was the implant single (33.8%) (p<0.05). Patient satisfaction was higher in the implant-teeth connective group (4.06 points) and the group without bone grafting (4.03 points) (p<0.01). Factor analysis showed that implant satisfaction was 0.43 times lower in the single implant group and 0.44 times lower in the implant-implant connective group than in the implant-teeth connective group. As a result of the study, it is expected that the method of extending the life of adjacent teeth and restoring the function of the tooth defect region is an implant-teeth connection method, so that it can be utilized positively through various clinical studies.

The Comparison between the success rates of single implants replacing the mandibular first and second molar (하악 제1, 2 대구치를 대체하는 단일 임프란트 간의 성공률 비교)

  • Lee, Hang-Bin;Paik, Jung-Won;Kim, Chang-Sung;Choi, Seong-Ho;Lee, Keun-Woo;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.101-112
    • /
    • 2004
  • Osseointegrated implnats have proven to be successful in both full and partial edentulous patients since the 1960s and recently have shown successful results when used to restore single tooth missing. However, in most studies reporting the success of single implants, single implants replacing anterior teeth are more frequently mentioned than posterior single implants. Moreover, in studies regarding posterior single implants, the replaced region seemed to be variable; the maxilla, mandible and areas from the first premolar to the second molar were mentioned. However, considering the difference in bone quality in the mandible and maxilla, and the increased occlusal force in the posterior region, the success rates in each region may be different. In this study, the cumulative success rates and amount of bone loss of single implants replacing the mandibular first and second molar, respectively, were compared and analyzed to come to the following conclusion. 1. The 20 (20 persons) single implants that were placed in the mandibular first molar region were all successful and showed a 100% 5 year cumulative success rate. Among the 27 (24 persons) single implants replacing the mandibular second molar, 8 failed (27.63%) showing a 5 year cumulative success rate of 70.37%. 2. Among the 8 failed implants, one showed symptoms of postoperative infection and one complained of parenthesia. 6 implants failed after functional loading; 5 showed mobility and one resulted in fixture fracture. 3. After the attachment of the prosthesis, there was no significant statistical difference regarding the marginal bone loss in group 1 and group 2 during the checkup period (P>0.05). In conclusion, restoration of the mandibular first molar using single implants was found to be an excellent treatment modality, and when replacing mandibular second molars with single implants, poor bone quality and risk of overloading must be considered.

Esthetic outcome for maxillary anterior single implants assessed by different dental specialists

  • Al-Dosari, Abdullah;Al-Rowis, Ra'ed;Moslem, Feras;Alshehri, Fahad;Ballo, Ahmed M.
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.345-353
    • /
    • 2016
  • PURPOSE. The aim of this study was to assess the esthetic outcome of maxillary anterior single implants by comparing the esthetic perception of dental professionals and patients. MATERIALS AND METHODS. Twenty-three patients with single implants in the esthetic zone were enrolled in this study. Dentists of four different dental specialties (Three orthodontists, three oral surgeons, three prosthodontists, and three periodontists) evaluated the pink esthetic score (PES)/white esthetic score (WES) for 23 implant-supported single restorations. The satisfactions of the patients on the esthetic outcome of the treatment have been evaluated according to the visual analog scale (VAS). RESULTS. The mean total PES/WES was $12.26{\pm}4.76$. The mean PES was $6.45{\pm}2.78$ and mean WES was $5.80{\pm}2.82$. There was a statistically significant difference among the different specialties for WES (P<.01) and Total PES/WES (P<.01). Prosthodontists were found to have assigned poorer ratings among the other specialties, while oral surgeons gave the higher ratings than periodontists, orthodontists, and prosthodontists. CONCLUSION. Prosthodontists seemed to be stricter when assessing aesthetic outcome among other specialties. Moreover, a clear correlation existed between dentists' and patients' esthetic perception, thereby providing rationales for involving patients in the treatment plan to achieve higher levels of patient satisfaction.

Retrospective Study of Wide-Diameter Implants in Maxillary & Mandibular Molar regions (상하악 대구치 부위에서 넓은 직경 임플란트의 생존율에 대한 후향적 연구)

  • Park, Kyung-Ah;Jeong, Cheol-Woong;Ryoo, Gyeong-Ho;Park, Kwang-Bum;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.825-838
    • /
    • 2007
  • Endosseous implants are used in the treatment of various types of tooth loss, and numerous long-term studies have demonstrated the excellent reliability of this method of treatment. However, the increase of implant failure are associated with inadequate quality and/or height of bone. At the end of the 1980s, Wide(>3.75mm) implants were initially used for managing these difficult bone situations. The recommended indications for its use included poor bone quality, inadequate bone height. immediate placement in fresh extraction sockets, and immediate replacement of failed implants. At the 2000s, wider implants(6.0mm and 6.5mm) were used in a few studies. Although good clinical outcomes have been reported in recent years, there is still a controversy on this topic. Therefore, the purpose of this study was to estimate the survival rate of wide implants($6.0{\sim}8.0mm$) in molar regions, evaluating the clinical outcome. In this study, 1135 RBM surfaced wide implants($Rescue^{TM}$, MEGAZEN Co., Korea/595 maxillary, 540 mandibular) were placed in 650 patients(403 male, 247 female/age mean: $51.2{\pm}11.1$ years, range 20 to 83 years). Of the total, 68.3% were used to treat fully or partially edentulous situations, including single-tooth losses and 31.7% were placed immediately after teeth extraction or removal of failed implants, of which all were in the molar regions. Implant diameter and length ranged from 6.0 to 8.0mm and from 5.0 to 10.0mm respectively. The implants were followed for up to 42 months (mean: $14.6{\pm}9.5$ months). Of 1135 placed implants, 58 implants were lost. Among them, 53 implants were lost within 12 months after implant placement. The survival rate was 93.6% in the maxilla and 96.3% in the mandible, yielding an overall survival rate of 94.9%, for up to 42 months. As the result of Cox regression model, prosthetic type, sinus graft, and patient gender have an statistical significance on the implant survival rate in this study. This study suggests that the use of wide implants($6.0{\sim}8.0mm$) would provide a predictable treatment alternative in posterior areas.