• 제목/요약/키워드: single-cell

검색결과 3,821건 처리시간 0.029초

The Single-Cell Revelation of Thermogenic Adipose Tissue

  • Qi, Yue;Hui, Xiaoyan Hannah
    • Molecules and Cells
    • /
    • 제45권10호
    • /
    • pp.673-684
    • /
    • 2022
  • The past two decades have witnessed an upsurge in the appreciation of adipose tissue (AT) as an immunometabolic hub harbouring heterogeneous cell populations that collectively fine-tune systemic metabolic homeostasis. Technological advancements, especially single-cell transcriptomics, have offered an unprecedented opportunity for dissecting the sophisticated cellular networks and compositional dynamics underpinning AT remodelling. The "re-discovery" of functional brown adipose tissue dissipating heat energy in human adults has aroused tremendous interest in exploiting the mechanisms underpinning the engagement of AT thermogenesis for combating human obesity. In this review, we aim to summarise and evaluate the use of single-cell transcriptomics that contribute to a better appreciation of the cellular plasticity and intercellular crosstalk in thermogenic AT.

Simulation of Containment Pressurization in a Large Break-Loss of Coolant Accident Using Single-Cell and Multicell Models and CONTAIN Code

  • Noori-Kalkhoran, Omid;Shirani, Amir Saied;Ahangari, Rohollah
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1140-1153
    • /
    • 2016
  • Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA) by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model). In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP) containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code's results.

다시마(Laminaria japonica)를 single cell detritus로 분해하는 해양세균의 분리 (Isolation of Marine Bacterium Decomposing Sea tangle (Laminaria japonica) to Single Cell Detritus)

  • 이건욱;신일식
    • 한국식품과학회지
    • /
    • 제38권2호
    • /
    • pp.237-240
    • /
    • 2006
  • 다시마(Laminaria japonica)를 기능성 식품소재로 활용하기 위한 예비단계로, 다세포의 다시마를 미립자의 single cell detritus(SCD)로 분해하는 해양세균을 해수, 다시마(Laminaria japonica), 미역(Undaria pinnatifida), 성게(Anthocidaris crassispina), 불가사리(Acanthaster planci), 소라(Batillus cornutus)로부터 분리하였다. 분리한 71개의 균주 중 다시마 조체의 연화능과 알긴산 분해활성을 동시에 가지는 균주는 14개이었으며, 균주 No. 34가 가장 강한 다시마 조체의 연화능과 알긴산 분해활성을 나타내었다. 균주 No. 34는 배양 15일 만에 다세포의 다시마를 미립자의 SCD 형태로 분해하였으며, 그 크기는 $5-10{\mu}m$이었다. 균주 No. 34는 vibrio sp.으로 동정되었으며, Vibrio sp. YKW-34로 명명하였다.

Strategy of Patient-Specific Therapeutics in Cardiovascular Disease Through Single-Cell RNA Sequencing

  • Yunseo Jung;Juyeong Kim;Howon Jang;Gwanhyeon Kim;Yoo-Wook Kwon
    • Korean Circulation Journal
    • /
    • 제53권1호
    • /
    • pp.1-16
    • /
    • 2023
  • Recently, single cell RNA sequencing (scRNA-seq) technology has enabled the discovery of novel or rare subtypes of cells and their characteristics. This technique has advanced unprecedented biomedical research by enabling the profiling and analysis of the transcriptomes of single cells at high resolution and throughput. Thus, scRNA-seq has contributed to recent advances in cardiovascular research by the generation of cell atlases of heart and blood vessels and the elucidation of mechanisms involved in cardiovascular development and diseases. This review summarizes the overall workflow of the scRNA-seq technique itself and key findings in the cardiovascular development and diseases based on the previous studies. In particular, we focused on how the single-cell sequencing technology can be utilized in clinical field and precision medicine to treat specific diseases.

Performance Evaluation of Platinum Dispersed Self-humidifying Polymer Electrolyte Membrane Prepared by Using RF Magnetron Sputter

  • Kwak, Sang-Hee;Yang, Tae-Hyun;Kim, Chang-Soo;Yoon, Ki-Hyun
    • 한국세라믹학회지
    • /
    • 제40권2호
    • /
    • pp.118-122
    • /
    • 2003
  • The performance evaluation on Pt loading in the self-humidifying polymer electrolyte membrane for Polymer Electrolyte Mem-Brane Fuel Cell(PEMFC) was investigated by using single cell test and measurement of membrane resistance. The self-humidifying membrane comprised two membranes made of perfluorosulfonylfluroride copolymer resin and fine Pt particles tying between them, coated by sputtering. From the results of performance characteristics of self-humidifying membrane cell with different Pt loading, a single cell using self-humidifying membrane with 0.15 mg/$\textrm{cm}^2$ Pt loading showed better performance than that with the others over entire current density. Also, a single cell with 0.15 mg/$\textrm{cm}^2$ Pt loading had a lower resistance value than the other cells under externally nonhumidifying condition. It is indicated that the water produced in the membrane cell with 0.15 mg/$\textrm{cm}^2$ Pt loading showed a higher provision to maintain ionic conductivity of the membrane than the other cells. The optimum amount of Pt particles embedded in the membrane for self-humidifying PEMFC was determined to be about 0.15 mg/$\textrm{cm}^2$.

인산형 연료전지 단위전지 200시간 운전특성 연구 (200hrs Operational Characteristics of the Single Cell in Phosphoric Acid Fuel Cell)

  • 송락현;김창수;최병우;한성옥;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.73-77
    • /
    • 1991
  • 200hrs operational characteristics of the single cell in phosphoric acid fuel cell was studied. The initial performance of single cells was examined as a function of PTFE content of electrode in the range of 30 to 60 wt.%. The cell with the electrode of 40wt.% PTFE was chosen for the 200hrs operation. The cell voltage decay was found to be about 0.5mV/hr for 200hrs operation. These results of cell performance were discussed as related to the internal resistance and the exchange current density of the cell.

  • PDF

Direct somatic embryogenesis, plant regeneration and genetic transformation of Panax ginseng

  • Park, Yong-Eui;Yang, Deok-Chun;Park, Kwang-Tae;Soh, Woong-Young;Hiroshi Sano
    • 한국식물학회:학술대회논문집
    • /
    • 한국식물학회 1999년도 제13회 식물생명공학심포지움 New Approaches to Understand Gene Function in Plants and Application to Plant Biotechnology
    • /
    • pp.85-89
    • /
    • 1999
  • Somatic embryogendesis is one of good examples of the basic research for plant embryo development as well as an important technique for plant biotechnology. This paper describes the direct somatic embryogenesis from zygotic embryos of Panax ginseng is reversely related to normal axis growth of zygotic embryos by the experiment of various chemical treatments. Under the normal growth condition, the apical tips of embryo axis produced an agar-diffusible substance, which suppressed somatic embryo development from cotyledons. Although the cells of zygotic embryos were released from the restraint of embryo axis, various factors were still involved for somatic embryo development. Electron microscopic observation revealed that the ultrastructure of cells of cotyledon epidermis markedly changed before initiation of embryonic cell division, probably indicating reprogramming events into the cells embryogenically determined state. Polar accumulation of endogenous auxin or cell-cell isolation by plasmolysis pre-treatment is the strong inducer for the somatic embryo development. The cells for the process of somatic embryogenesis might be determined by the physiological conditions fo explants and medium compositions. Direct somatic embryos from cotyledons fo ginseng were originated eithrer from single or multiple cells. The different cellular origin of somatic embryos was originated either from single or multiple cell. The different cellular origin of somatic embryos was depended on various developmental stages of cotyledons. Immature meristematic cotyledons produced multiple cell-derived somatic embryos, which developed into multiple embryos. While fully mature cotyledons produced single cell-derived single embryos with independent state. Plasmolysis pretreatment of cotyledons strongly enhanced single cell-derived somatic embryogenesis. Single embryos were converted into normal plantlets with shoot and roots, while multiple embryos were converted into only multiple shoots. GA3 or a chilling treatment was prerequisite for germination and plant conversion. Low concentration of ammonium ion in medium was necessary for balanced growth of root and shoot of plantlets. Therefore, using above procedures, successful plant regeneration of ginseng was accomplished through direct single embryogenesis, which makes it possible to produce genetically transformed ginseng efficently.

  • PDF

Ag 집전체를 적용한 평판형 SOFC 단전지 (Single Cell Stacked Planar Type SOFC Assembled Using a Ag-Current Collector)

  • 조남웅;황순철;이인성
    • 한국세라믹학회지
    • /
    • 제44권12호
    • /
    • pp.720-726
    • /
    • 2007
  • Current collectors of SOFC play a significant role on the performance of power generation. In this study a single cell stacked SOFC was assembled using Ag-mesh as a cathode current collector, and evaluated its performance. No gas leakages of the single cell stack occurred in the tests of gas detection and OCV measurement. The OCV and initial power of the stack were 1.09V and $0.45W/cm^2$, respectively, under the flow rates of air at 2,500 cc/min and $H_2$ at 1,000 cc/min at the test temperature of $750^{\circ}C$. A degradation rate of 44.0% was measured during the prolonged time of 307 h. The relatively low durability of the tested single cell stack was found to be the evaporation of Ag-mesh at the current corrector.

Assessment of direct glycerol alkaline fuel cell based on Au/C catalyst and microporous membrane

  • Yongprapat, Sarayut;Therdthianwong, Apichai;Therdthianwong, Supaporn
    • Advances in Energy Research
    • /
    • 제2권1호
    • /
    • pp.21-31
    • /
    • 2014
  • The use of a microporous membrane along with Au/C catalyst for direct glycerol alkaline fuel cell was investigated. In comparison with Nafion 112, the microporous Celgard 3401 membrane provides a better cell performance due to the lower ionic resistance as confirmed by impedance spectra. The single cell using Au/C as anode catalyst prepared by using PVA protection techniques provided a higher maximum power density than the single cell with commercial PtRu/C at $18.65mW\;cm^{-2}$ The short-term current decay studies show a better stability of Au/C single cell. The higher activity of Au/C over PtRu/C was owing to the lower activation loss of Awe. The magnitude of current decay indicates a low problem of glycerol crossover from anode to cathode side. The similar performance of single cell with and without humudification at cathode points out an adequate transport of water through the microporous membrane.

Effects of Non-Uniform Traffic Distribution on the Capacity of Reverse Link CDMA System

  • Cho, Choon-Geun;Ann, Jong-Hoon;Tchah, Kyun-Hyon
    • 한국통신학회논문지
    • /
    • 제25권12A호
    • /
    • pp.1828-1835
    • /
    • 2000
  • In this paper, we analyzed the other-cell interference characteristics for various non-uniform traffic distributions and their effects on the capacity of multi-cell CDMA system. We consider three different traffic distributions, i.e., linear, exponential and Gaussian traffic distribution with distribution parameters. Changing the distribution parameter, we can obtain the center-focused distributions or uniform distributions for each model. From the results of other-cell interference calculation we can see that the other-cell interference decreases, as the user concentrates on the base station. Also using frequency reuse efficiency indicating the capacity reduction of a multi-cell system when compared to a single cell system, we evaluate the effect of traffic distribution on the reverse link CDMA capacity. For linear case, the capacity of multi-cell system is reduced to 0.637∼0.867 times that of single cell system. On the other hand, for both exponential and Gaussian cases, the capacity under a multi-cell environment is equal to 70∼100% of that under a single cell. Therefore, we conclude that the average capacity of multi-cell CDMA system are increased when users are likely to be at near the cell base station due to reduced total other-cell interference and decreased when users exist at near the cell edge regardless of traffic distribution models.

  • PDF