• 제목/요약/키워드: single point contact

검색결과 73건 처리시간 0.029초

스퍼기어의 접촉응력 해석 (Contact Stress Analysis of a Pair of Mating Spur Gears)

  • 이진환;이동형;이권희
    • 한국기계가공학회지
    • /
    • 제9권4호
    • /
    • pp.59-65
    • /
    • 2010
  • This paper presents the study on the contact stress analysis of a pair of mating spur gears during rotation. Contact stress analysis is performed between two spur gear teeth at different contact positions during rotation. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. The results show that contact stress varies along the contact position and gets maximum values in the beginning and end of the contact. In this study, the gear design considering the contact stress on a pair of mating gears is more severe than that of AGMA standard.

터보블로워용 헬리컬 기어의 접촉응력 해석 (Contact Stress Analysis of Helical Gear for Turbo Blower)

  • 황석철;이동형;박영철;이권희
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.90-95
    • /
    • 2011
  • This paper presents the study on the contact stress analysis of a pair of mating helical gears for turbo blower during rotation. Turbo blowers need high speed rotation of impeller in structure and high rate gear ratio. The use of helical gear indicated that noise was an important problem when the application involves high speeds and large power transmission. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at the lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. In this study, the gear design considering the contact stress on a pair of mating gear is more severe than that of AGMA standard.

정전용량형 센서를 이용한 기상계측시스템의 개발 (Development of On-machine Measurement System utilizing a Capacitive-type Sensor)

  • 김건희;박순섭;박원규;원종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.391-395
    • /
    • 2002
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on the single point diamond turning machine(SPDTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of On-machine Measurement System in this investigation is capable of providing a repeatability of 20 nanometers with a $\pm$20 uncertainty of 300 nanometers.

  • PDF

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

상악 전치부 단일 임플란트 지지 수복금관의 주변 연조직반응의 단면적 연구 (Soft tissue reactions around implant-supported single-tooth replacements in the maxillary anterior region)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.321-337
    • /
    • 1998
  • The aims of this study were firstly to investigate soft tissue reactions around single implant-supported crowns and secondly to compare soft tissue dimensions and conditions of the crowns in relation to interdental papillae, and lastly to investigate patients'esthetic satisfaction with their single implant-supported crowns according to the interdental papillae presence/absence. Twenty-nine patients (41 implants) whose single missing tooth in the maxillary anterior region had been replaced by single implant-supported crown participated for the study and various variables of soft tissue conditions, dimensions and crown dimensions were measured around the single implant-supported crowns at clinical examination and from study models and slides. The results showed that the soft tissue conditions around the single implantsupported crowns were similar to those around implants used for partially or totolly edentulous patients. Except for the high frequency of bleeding on probing, all other parameters revealed healthy conditions. The buccal sites of the crown had a shallow pocket comparing with other sites. At all sites of the crown, similar status of little inflammation was found. Mesial sites and central-incisor positioned implantsupported crowns had lower contact point position than distal sites and lateral-incisor positioned crowns, respectively. Mucositis index, probing depth and contact point position were significantly correlated with papillae index(p < 0.05). More inflammation and lower contact point position were found at the implant-supported crown with no interdental space than that with interdental space. Patients showed high esthetic satisfaction regardless of interdental space presence. The result indicated that, despite of their submucosal crown margins, single implantsupported crowns have soft tissue conditions as good as other implants used for the treatment of the different types of edentulism and a clinician can manipulate interdental papilla height by modifying crown shapes within the limits of not violating total esthetics.

  • PDF

접촉점에서의 국소 그래프 패턴에 의한 필기체 한글의 자소분리에 관한 연구 (A Study on the Phoneme Segmentation of Handwritten Korean Characters by Local Graph Patterns on Contacting Points)

  • 최필웅;이기영;구하성;고형화
    • 전자공학회논문지B
    • /
    • 제30B권4호
    • /
    • pp.1-10
    • /
    • 1993
  • In this paper, a new method of phoneme segmentation of handwritten Korean characters using the local graph pattern is proposed. At first, thinning was performed before extracting features. End-point, inflexion-point, branch-point and cross-point were extracted as features. Using these features and the angular relations between these features, local graph pattern was made. When local graph pattern is made, the of strokes is investigated on contacting point. From this process, pattern is simplified as contacting pattern of the basic form and the contacting form we must take into account can be restricted within fixed region, 4therefore phoneme segmentation not influenced by characters form and any other contact in a single character is performed as matching this local graph pattern with base patterns searched ahead. This experiments with 540 characters have been conducted. From the result of this experiment, it is shown that phoneme segmentation is independent of characters form and other contact in a single character to obtain a correct segmentation rate of 95%, manages it efficiently to reduce the time spent in lock operation when the lock.

  • PDF

대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성 (Near Visual Performance of Multifocal Contact Lenses in University Students)

  • 정우철;김수현;김재민
    • 한국안광학회지
    • /
    • 제16권1호
    • /
    • pp.51-60
    • /
    • 2011
  • 목적: 본 연구는 대학생들을 대상으로 근거리에서 낮은 가입도 멀티포컬 소프트렌즈의 시기능과 만족도를 조사하고자 시행하였다. 방법: 특별한 안질환이 없고 양안 교정시력이 20/20(1.0) 이상인 대학생 26명(남자 6명, 여자 20명)을 대상으로 단초점렌즈와 낮은 가입도(Low addition)의 멀티포컬 소프트렌즈를 피팅하였다. 2주 착용한 후, 시기능검사는 원거리와 근거리 교정시력, 입체시, 대비감도, 조절근점, 조절용이성, 폭주근점, 버전스 용이성, 근거리 선명시역을 측정하였다. 설문조사는 전반적 만족도와 선호도의 항목으로 구성하여 조사하였다. 결과: 양안으로 검사한 원거리와 근거리의 시력은 2가지 렌즈를 착용한 경우 모두 20/20 이상이었다. 원거리와 근거리 입체시, 대비감도와 버전스 용이성은 멀티포컬과 단초점 소프트렌즈에서 통계적으로 의미있는 차이가 없었다. 양안으로 측정한 조절근점, 조절용이성, 폭주근점 그리고 근거리 선명시역은 전반적으로 멀티포컬 소프트렌즈의 착용 후 단초점렌즈보다 우수하였다. 설문조사는 근거리작업과 관련된 항목에서 멀티포컬 소프트렌즈, 원거리와 관련된 항목에 단초점렌즈를 선호하고 만족하는 것으로 나타났다. 결론: 대부분의 대학생들이 근거리 작업과 관련된 시기능 유용성에서 멀티포컬 소프트렌즈가 더 좋았기 때문에 단초점 콘택트렌즈보다 멀티포컬 소프트렌즈를 선호했다. 본 연구의 결과로 멀티포컬 소프트렌즈의 착용이 장시간 근거리 시생활하는 대학생에게 유용할 것으로 사료된다.