• Title/Summary/Keyword: single photon detector

Search Result 46, Processing Time 0.024 seconds

Plug & Play quantum cryptography system (Plug & Play 양자암호 시스템)

  • Lee, Kyung-Woon;Park, Chul-Woo;Park, Jun-Bum;Lee, Seung-Hun;Shin, Hyun-Jun;Park, Jung-Ho;Moon, Sung-Wook
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.45-50
    • /
    • 2007
  • We present a auto compensating quantum key distribution system based on optical fiber at 1550nm. In the quantum key transmission system, main control board and phase modulation driving board are fabricated for auto controlling quantum key distribution(QKD). We tested the single photon counts per dark counts for a single photon detector, quantum key distribution rate($R_{sift}$) and the quantum bit error rate (QBER). Quantum bit error rate of 3.5% in 25km QKD is obtained. This system is commercially available.

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

A Study of the Inorganic Scintillator Properties for a Phoswich Detector (Phoswich 검출기 제작을 위한 무기 섬광체 특성 연구)

  • Lee, Woo-Gyo;Kim, Yong-Kyun;Kim, Jong-Kyung;Tarasov, V.;Zelenskaya, O.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.251-256
    • /
    • 2004
  • CsI(Tl), $CdWO_4(CWO),\;Bi_4Ge_3O_{12}(BGO)\;and\;Gd_2SiO_5:Ce(GSO)$ scintillators were studied to manufacture a phoswich detector. The maximum wavelengths of the CsI(Tl), CWO, BGO and GSO scintillators are 550 nm, 475 nm, 490 nm and 440 nm for the radioluminescence, and the absolute light outputs of the CsI(Tl), CWO, BGO and GSO scintillators are 54890 phonon/MeV, 17762 phonon/MeV, 8322 phonon/MeV and 8932 phonon/MeV with a neutral filter, and the decay time of the CsI(Tl), CWO, BGO and GSO scintillators is $1.3{\mu}s,\;8.17{\mu}s$, 213 ns and 37 ns by a single photon method. The phoswich detector which was manufactured with plastic and CsI(Tl) scintillators could separate the ${\beta}$ particle and ${\gamma}$ ray. The phoswich detector could also measure the pulse height spectra of the ${\beta}$ particle and ${\gamma}$ ray by a PSD method.

Low-noise fast-response readout circuit to improve coincidence time resolution

  • Jiwoong Jung;Yong Choi;Seunghun Back;Jin Ho Jung;Sangwon Lee;Yeonkyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1532-1537
    • /
    • 2024
  • Time-of-flight (TOF) PET detectors with fast-rise-time scintillators and fast-single photon time resolution silicon photomultiplier (SiPM) have been developed to improve the coincidence timing resolution (CTR) to sub-100 ps. The CTR can be further improved with an optimal bandwidth and minimized electronic noise in the readout circuit and this helps reduce the distortion of the fast signals generated from the TOF-PET detector. The purpose of this study was to develop an ultra-high frequency and fully-differential (UF-FD) readout circuit that minimizes distortion in the fast signals produced using TOF-PET detectors, and suppresses the impact of the electronic noise generated from the detector and front-end readout circuits. The proposed UF-FD readout circuit is composed of two differential amplifiers (time) and a current feedback operational amplifier (energy). The ultra-high frequency differential (7 GHz) amplifiers can reduce the common ground noise in the fully-differential mode and minimize the distortion in the fast signal. The CTR and energy resolution were measured to evaluate the performance of the UF-FD readout circuit. These results were compared with those obtained from a high-frequency and single ended readout circuit. The experiment results indicated that the UF-FD readout circuit proposed in this study could substantially improve the best achievable CTR of TOF-PET detectors.

Development of SWIR 3D Lidar System with Low Optical Power Using 1 Channel Single Photon Detector (1채널 단일광자검출기를 이용한 낮은 광출력의 SWIR(Short Wave Infrared) 3D 라이다 시스템 개발)

  • Kwon, Oh-Soung;Lee, Seung-Pil;Shin, Seung-Min;Park, Min-Young;Ban, Chang-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1147-1154
    • /
    • 2022
  • Now that the development of autonomous driving is progressing, LiDAR has become an indispensable element. However, LiDAR is a device that uses lasers, and laser side effects may occur. One of them is the much-talked-about eye-safety, and developers have been satisfying this through laser characteristics and operation methods. But eye-safety is just one of the problems lasers pose. For example, irradiating a laser with a specific energy level or higher in a dusty environment can cause deterioration of the dust particles, leading to a sudden explosion. For this reason, the dust ignition proof regulations clearly state that "a source with a pulse period of less than 5 seconds is considered a continuous light source, and the average energy does not exceed 5 mJ/mm 2 or 35 mW" [2]. Energy of output optical power is limited by the law. In this way, the manufacturer cannot define the usage environment of the LiDAR, and the development of a LiDAR that can be used in such an environment can increase the ripple effect in terms of use in application fields using the LiDAR. In this paper, we develop a LiDAR with low optical power that can be used in environments where high power lasers can cause problems, evaluate its performance. Also, we discuss and present one of the directions for the development of LiDAR with laser power limited by dust ignition proof regulations.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

The efficiency of the quantum key distribution depends on the characteristics of the detector system (양자암호화 키 전송에서 검출기 특성에 따른 전송효율)

  • 조기현;강장원;윤선현
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.71-76
    • /
    • 2001
  • We studied quantum cryptography based on the quantum nature of light. We must reduce the intensity of the light pulse to the single photon regime for quantum cryptographic communication. Considering the noise and the quantum efficiency of the detector, however, we have to fmd a criterion for which we are able to distinguish the error caused by eavesdropping from other system noises. By changing the bias voltage of the detector and the threshold of the signal voltage, we find the safe region for which we can distribute the quantum key with positive proof of no-eavesdropping. The quantum key we used is a four state quantum key (BB84). BB84).

  • PDF

Implementation and benchmarking of the local weight window generation function for OpenMC

  • Hu, Yuan;Yan, Sha;Qiu, Yuefeng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3803-3810
    • /
    • 2022
  • OpenMC is a community-driven open-source Monte Carlo neutron and photon transport simulation code. The Weight Window Mesh (WWM) function and an automatic Global Variance Reduction (GVR) method was recently developed and implemented in a developmental branch of OpenMC. This WWM function and GVR method broaden OpenMC's usage in general purposes deep penetration shielding calculations. However, the Local Variance Reduction (LVR) method, which suits the source-detector problem, is still missing in OpenMC. In this work, the Weight Window Generator (WWG) function has been developed and benchmarked for the same branch. This WWG function allows OpenMC to generate the WWM for the source-detector problem on its own. Single-material cases with varying shielding and sources were used to benchmark the WWG function and investigate how to set up the particle histories utilized in WWG-run and WWM-run. Results show that there is a maximum improvement of WWM generated by WWG. Based on the above results, instructions on determining the particle histories utilized in WWG-run and WWM-run for optimal computation efficiency are given and tested with a few multi-material cases. These benchmarks demonstrate the ability of the OpenMC WWG function and the above instructions for the source-detector problem. This developmental branch will be released and merged into the main distribution in the future.

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

PERFORMANCE OF FIMS MICROCHANNEL PLATE DETECTOR SYSTEM (FIMS의 마이크로채널 플레이트 검출기 시스템의 특성)

  • Nam, U.W.;Rhee, J.G.;Kong, K.N.;Park, Y.S.;Jin, K.C.;Jin, H.;Park, J.H.;Yuk, I.S.;Seon, K.I.;Han, W.;Lee, D.H.;Ryu, K.S.;Min, K.W.;Edelstein, J.;Korpela, E.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • We describe some performance of the detector electronics system for the FIMS (Far-ultraviolet Imaging Spectrograph) mission. The FIMS mission to map the far ultraviolet sky uses MCP (micro-channel plate) detectors with a crossed delay line anode to record photon arrival events. FIMS has two MCP detectors, each with a ~25mm$\times$25mm active area. The unconventional anode design allows for the use of a single set of position encoding electronics for both detector fields. The centroid position of the charge cloud, generated by the photon-stimulated MCP, is determined by measuring the arrival times at both ends of the anode following amplification and external delay. The temporal response of the detector electronics system determines the readout's positional resolution for the charge centroid. High temporal resolution (<$35{\times}75$ps FWHM) and low power consumption (< 6W) were achieved for the FIMS detector electronics system.