• Title/Summary/Keyword: single loop control

Search Result 303, Processing Time 0.025 seconds

New dual cascade loop controller with color LCD bar graphs, equipped with a memory card

  • Kanda, Masae;Uyeno, Mitsugu;Matsuo, Akira;Souda, Yasushi;Terauchi, Yukio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1327-1331
    • /
    • 1990
  • A new dual loop controller using color LCD bar graphs with LED back lights has been developed. An optional memory card is used to load or save the controller configuration, which may be a preprogrammed standard package or a user-programmed configuration, in addition to the built-in functions ready for user selection. The bar-graph display is selectable for single-loop or dual-loop use. A high grade of self-tuning functions using a modeling technique is built-in as standard. The controller can accommodate optional plug-in modules for thermocouples, communication, etc. All the options are fully field upgradable.

  • PDF

Input Current Ripple Improvement on Interleaved Boost Power Factor Corrector Operating in Discontinuous Current Mode (불연속 전류모드로 동작하는 Interleaved 승압형 역률보상 컨버터의 입력전류 리플개선)

  • 허태원;박지호;노태균;김동완;박한석;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.116-123
    • /
    • 2003
  • In this paper, interleaved boost converter is applied as a pre-regulator in switched mode power supply. The pre-regulator plays a role to improve power factor. Interleaved Boost Power Factor Corrector(IBPFC) can reduce input current ripple as a single voltage control loop only without inner current loop, because input current is divided each 50% by two switching devices. Each converter cell is also operated in discontinuous current mode and inductor current of each converter is discontinuous. Total input current which is composed by each converter cell is continuous current. Thus, IBPFC is able to improve input current ripple. IBPFC operating in discontinuous current mode can be classified as six modes from switching state and be carried out state space averaging small signal modeling. A control transfer function is obtained according to the modeling. Single voltage control loop is also constructed by the control transfer function. From experimental result, improvement of power factor and input current ripple are verified.

Sliding Mode Control for Time-delay System using Virtual State (가상 상태를 이용한 시간 지연 시스템의 슬라이딩 모드 제어)

  • 송영삼;권성하;박승규;오도창;정은태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.341-341
    • /
    • 2000
  • This paper presents a sliding mode control(SMC) design method for single input linear systems with uncertainties and time delay in the state. We define a sliding surface for the augmented system with a virtual state which is defined from the nominal system. We make a virtual state from optimal control input using LOR(Linear Quadratic Regulator) and the states of the nominal system. We construct a controller that combines SMC with optimal controller. The proposed sliding mode controller stabilizes on the overall closed-loop system.

  • PDF

Stability Analysis of Single-input Fuzzy Logic Controller (단일 입력 퍼지논리제어기의 안정성 분석)

  • 최병재
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.05a
    • /
    • pp.47-51
    • /
    • 2001
  • According as the controlled plants become more complex and large-scaled, the development of more intelligent control schemes is required in the control field. A fuzzy logic control (FLC) is one of proper schemes for this tendency. Recently, fuzzy control has been applied successfully to many industrial applications due to a number of advantages. But it still has some disadvantages. The conventional FLC has many tuning parameters: membership functions, scaling factors, and so forth. In order to improve this problem, a single-input fuzzy logic control (SFIC) which greatly simplifies the design process of the conventional FLC was proposed. Many research has also been proposed to develop the stability analysis of the FLC. In this paper we analyze the absolute stability of the SFLC. We first expand a nonlinear controlled plant into a Taylor series about a nominal operating point. And a fuzzy control system is transformed into a Lure system with nonlinearities. We also prove that the closed-loop system with the SFLC satisfies the sector condition globally.

  • PDF

A Fuzzy Control for Boiler System of Fossil-Power Plant (화력발전 보일러를 위한 퍼지제어기의 설계)

  • Moon, Un-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.140-142
    • /
    • 2001
  • Three single loop fuzzy logic controllers are designed independently for the control of boiler system of fossil-power plant. The control rules and the membership functions of proposed fuzzy logic control system are generated automatically without using plant model. The simulation shows successful results for wide range operation of boiler system of fossil-power plant.

  • PDF

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

Risk Decrease Method for Component Control System of Nuclear Power Plant (원전기기제어시스템의 위험도 감소 방안)

  • Cho, Chang-Hwan;Kim, Jung-Seon;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.227-228
    • /
    • 2007
  • 디지털기술의 발전으로 원자력발전소의 기기제어시스템은 Single-loop Control과 하드와이어드된 배선을 이용한 제어방식에서 Multi-loop Control과 통신망을 이용한 제어방식으로 변화되고 있다. 이에 따라 기기제어시스템의 단일고장발생시 플랜트 위험도가 증가하게 됨으로 플랜트 위험도 감소를 위한 연구가 필요하다. 위험도 감소를 위한 방안에는 기기제어시스템을 구성하는 기기의 신뢰도를 향상시키는 방법과 제어루프에 작동기기를 적절하게 배치하여 단일고장발생시 플랜트 위험도를 감소시키는 방법이 있다. 본 논문에서는 플랜트 위험도 감소 방안 중 작동기기 할당 방안에 대해 기술하였다.

  • PDF

Assessment of Three-Phase Actuated Signal Operation at Diamond Interchanges (다이아몬드 인터체인지의 3 현시 신호운영 평가)

  • 이상수
    • Proceedings of the KOR-KST Conference
    • /
    • 2002.02a
    • /
    • pp.143-159
    • /
    • 2002
  • The performance of two single-barrier three-phase actuated control systems at diamond interchanges was evaluated for various traffic conditions. To emulate the actuated signal control, hardware-in-the-loop system combined with CORSIM simulation program was used. Two performance measures, average delay and total stops, were used for the evaluation process. Results showed that the two three-phase systems gave similar performance in terms of average delay, but not stops. The delay performance of each phasing system was generally dependent on the traffic pattern and ramp spacing. The total stops decreased as the spacing increased, and it was the most sensitive variable that can differentiate between the two three-phase systems. It was also shown that the hardware-in-the-loop control could provide a good method to overcome the limitations of current simulation technology.

  • PDF

Motion Control of a Single Rod Cylinder-Load System Driven by a Proportional Directional Control Valve (비례방향제어밸브에 의해 구동되는 차동 실린더 부하계의 운동제어)

  • Lee, M.W.;Cho, S.H.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.81-85
    • /
    • 2010
  • This paper deals with the issue of motion control of a single rod cylinder-load system using simple adaptive control (SAC) method. Prior to controller design, the experiment of open-loop response has been performed. Based on it, design parameters of transfer function are obtained. The effect of parallel feedforward compensator has been investigated by computer simulation, suppressing the oscillatory motion. Through experiments it is conformed that the SAC method gives good tracking performance compared to the PD control method.

  • PDF

Adaptive Fuzzy Sliding-Mode Controller for Nonaffine Nonlinear Systems (비어파인 비선형 계통에 대한 적응 퍼지 슬라이딩 모드 제어기)

  • Park, Jang-Hyun;Kim, Seong-Hwan;Lyoo, Young-Jae;Moon, Chae-Joo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.697-700
    • /
    • 2005
  • An adaptive fuzzy sliding-mode controller (SMC) for uncertain or ill-defined single-input single-output (SISO) nonaffine nonlinear systems is proposed. By using the universal approximation property of the fuzzy logic system (FLS), it is tuned on-line to cancel the unknown system nonlinearity. We adopt a self-structuring FLS to guarantee global stability of the closed-loop system rather than semi=global boundedness. The control and adaptive laws are derived so that the estimated fuzzy parameters are bounded and the sliding condition is satisfied.

  • PDF