• Title/Summary/Keyword: single layer high-T$_{}$ c/ superconducting cable

Search Result 3, Processing Time 0.015 seconds

Characteristics of AC Loss in a Single Layer High-$T_{c}$ Superconducting Model Cable under Uniform Current Distribution (균일 전류분포에서 단층 고온초전도 모델케이블의 교류손실 특성)

  • 정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.371-373
    • /
    • 2002
  • High current density Bi-2223 tapes have recently become commercially available. The ac loss is an important issue in the design of high-T$_{c}$ superconducting power cables. In such complicated devices, special caution is required in the placing of voltage leads for measuring the in-phase voltage. In this paper, the ac losses for different contacts and arrangements of voltage leads have been experimentally investigated in a single layer model cable and discussed.d.

  • PDF

The Evaluation of AC Loss in a Single Layer High-$T_{c}$ Superconducting Model Cable (단층 고온초전도 모델케이블의 교류손실 평가)

  • 정재훈;류경우;황시돌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.210-212
    • /
    • 2003
  • High current density Bi-2223 tapes have recently become commercially available. The ac loss is an important issue in the design of high-T$_{c}$ superconducting power cables. In such complicated devices, special caution is required in the placing of voltage leads for measuring the in-phase voltage. In this paper, the ac losses for different contacts and arrangements of voltage leads have been experimentally investigated in a single layer model cable and discussed.d.

  • PDF

Effect of the voltage lead configurations on AC Loss Measurement in a Single Layer High-Tc Superconducting Model Cable (전압리드의 배치가 단층 고온초전도 모델케이블의 교류손실 측정에 미치는 영향)

  • 류경우;정재훈;황시돌;김석환
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.670-675
    • /
    • 2002
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting Power cables. The cables consists of a number of Bi-2223 tapes wound on a former. In such cables tapes have different critical current characteristics intrinsically. And they are electrically connected to each other and current leads by soldering. These make loss measurements considerably complex, especially for short samples of laboratory size. Special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work the at losses in a single layer model cable have been experimentally investigated for different contacts and arrangements of voltage leads. The results show that the losses are not dependent on both arrangements and contact positions of the voltage leads. This implies that loss flux is only in a cylindrical conductor section. The measured losses also agree well with those based on a monoblock model and are independent of frequencies. This means that the measured AC loss of the model cable is purely hysteretic in nature.e.