• Title/Summary/Keyword: simultaneous resolution

Search Result 153, Processing Time 0.026 seconds

ANALYTIC APPROACH TO DEFORMATION OF RESOLUTION OF NORMAL ISOLATED SINGULARITIES: FORMAL DEFORMATIONS

  • Miyajima, Kimio
    • Journal of the Korean Mathematical Society
    • /
    • v.40 no.4
    • /
    • pp.709-725
    • /
    • 2003
  • We give an analytic approach to the versal deformation of a resolution of a germ of normal isolated singularities. In this paper, we treat only formal deformation theory and it is applied to complete the CR-description of the simultaneous resolution of a cone eve. a rational curve of degree n in P$^{n}$ (n $\leq$ 4).

A Proposal of Simultaneous Acquisition Performance Test Method for Telemetry System (원격 측정 시스템 동시계측 성능시험 방법 제안)

  • Park, Yu-kwang;Lee, Woon-moon;Kim, Bok-ki
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.3
    • /
    • pp.218-223
    • /
    • 2020
  • There are communication methods that guarantees real-time and method of performing the simultaneous acquisition through the synchronized multi-channels to improve the reliability of the telemetry system. Such synchronized systems need to be verified to confirm the simultaneous measurement performance of channels. In this paper, we propose a method to measure the time difference between synchronized channels in a telemetry system through simultaneous acquisition performance test. The simulation signal is applied for measurement and the difference between the sampling period and the simulation signal period is defined as the concept of time resolution. The principle of checking the measurement time difference between channels through time resolution was explained. In addition, the proposed principle was verified through simulation in the situation when measurement time difference may occur. And a procedure for identifying a measurement time difference in an actual telemetry system is described.

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.

Ultrasound Imaging Based On Simultaneous Multiple Transmit Focusing Using Orthogonal Modified Golay Code (직교하는 변형된 골레이(Golay) 코드를 이용한 동시 다중 집속 기반의 초음파 영상 기법)

  • Kim, B.H.;Jeong, Y.K.;Song, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.187-190
    • /
    • 2001
  • A new ultrasound imaging technique based on simultaneous multiple transmit focusing using orthogonal modified Golay codes is presented. modified Golay codes are used to increase signal-to-noise-ratio(SNR) and maximize the transmit power efficiency(TPE). Conventional Golay codes consist of a pair of complementary codes with same length and can be compressed into a delta-like signal due to their complementary property. In the present work, two modified Golay codes focused at different depths are transmitted at the same time, which are mutually orthogonal. On receive, these orthogonal modified Golay codes are separately compressed into two short pulses and individually focused. These two focused beam are combined to form a frame of image with improved lateral resolution. Computer simulations are performed to verity the proposed method improves the lateral resolution of image compared with the conventional echo system.

  • PDF

SIMULTANEOUS OBSERVATIONS OF HIGH RESOLUTION SPECTRA OVER A SUNSPOT UMBRA

  • Yun, Hong-Sik;Beebe, Herbert A.;Baggett, Wayne
    • Journal of The Korean Astronomical Society
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 1980
  • Simultaneous observations of high resolution spectra of CaII H, K, ${\lambda}8542\;and\;{\lambda}8498$ have been made over a sunspot umbra (SPO 5007) by means of Sacramento Peak Observatory's HIRKHAD program with the Echelle spectrograph at the Vacuum Tower Telescope. The observed spectra scanned by SPO's fast microphotometer have been reduced for later theoretical interpretations. The reduced profiles, sampled over a region which is thought to be coolest over the spot, are presented in units of absolute intensity. The core intensity ratios of $I(K_3)/I(H_3);and\;I({\lambda}8498)/I({\lambda}8542)$ arc found to be 1.3 and 1.14, respectively.

  • PDF

Simultaneous growth of graphene and vertically aligned single-walled carbon nanotubes at low temperature by chemical vapor deposition

  • Hong, Suck Won;Kim, Kwang Ho;Jung, Hyun Kyung;Kim, Daesuk;Lee, Hyung Woo
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.154-157
    • /
    • 2012
  • We present the simultaneous growth of single-walled carbon nanotubes and graphene with the optimal conditions of the synthesizing parameters. The dense and vertically aligned SWNTs having the length of over 100 ㎛ was grown by 2 nm-thick Fe catalytic layer. From 650 ℃, the vertically well-grown SWNTs were obtained by increasing the temperature. The severallayered graphene was synthesized with the gas mixing ratio of 15 : 1(H2 : C2H2) at 650 ℃ and higher temperatures. With these optimal conditions, the vertically well-grown SWNTs and the several-layered graphene were synthesized simultaneously. The presence of SWNTs and the layer of graphene were verified by field emission scanning electron microscopy and high resolution transmission electron microscopy. From the result of this simultaneous synthesizing approach, the possibility of one step growth process of CNTs and grapheme could be verified.

Quantitative Analysis by Derivative Spectrophotometry (III) -Simultaneous quantitation of vitamin B group and vitamin C in by multiple linear regression analysis-

  • Park, Man-Ki;Cho, Jung-Hwan
    • Archives of Pharmacal Research
    • /
    • v.11 no.1
    • /
    • pp.45-51
    • /
    • 1988
  • The feature of resolution enhancement by derivative operation is linked to one of the multivariate analysis, which is multiple linear regression with two options, all possible and stepwise regression. Examined samples were synthetic mixtures of 5 vitamins, thiamine mononitrate, riboflavin phosphate, nicotinamide, pyridoxine hydrochloride and ascorbic acid. All components in mixture were quantified with reasonably good accuracy and precision. Whole data processing procedure was accomplished on-line by the development of three computer programs written in APPLESOFT BASIC language.

  • PDF

3D Simulation of Environmental Conflict Resolution in Intelligent Environments

  • Lee, Jae-Wook
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.3-9
    • /
    • 2012
  • Owing to the advent of ubiquitous computing technologies, the concept of Intelligent Environments has emerged, as an alternative approach to overcome the limitation of the built environment. Intelligent Environments can be more responsive to user-and context-specific human activities by automatically and dynamically modifying their settings without explicit human intervention. However, the conventional approach to the development of Intelligent Environments has mainly focused on the technical issues without paying much attention to the dynamic interrelationship between the user and the built environment. Therefore, differing or conflicting needs of multiple simultaneous users remain unresolved. The objective of this study is to present types of environmental conflicts and their resolution through agent collaboration and negotiation. For the demonstration and validation of the conflict resolution process, a set of hypothetical test cases is simulated in a 3D test environment. The result of the case simulations shows that the proposed approach is computationally feasible and applicable to the development of Intelligent Environments, and, furthermore, it can overcome the drawback of the conventional approach.