• 제목/요약/키워드: simultaneous equation model

검색결과 107건 처리시간 0.023초

시스템검증법에 의한 조종성능해석연구 (Maneuverability Analysis of a Ship by System Indentification technique)

  • 강창구;서상현
    • 한국기계연구소 소보
    • /
    • 통권10호
    • /
    • pp.35-48
    • /
    • 1983
  • When the hydrodynamic coefficients of the ship maneuvering equation are estimated by captive model test, it is difficult to take account of the scale effect between model and full scale ship. This scale effect problem can be overcome by processing the sea trial data with system identification. Extended Kalman filter is used as a system identification technique for the modification of the simulation equation as well as the estimation of hydrodynamic coefficients. The phenomena of simultaneous drifting of linear coefficients occur. It is confirmed that two coefficients in each pair-($Y_v$', $Y_r$' -m' u'), ($N_v$', $N_r$' )-are simultaneously drifting and all 4 coefficients are simultaneously drifting together. Particularly simultaneous drifting of 2 coefficients in each pair is more significant. It is also shown that the simultaneous drifting of 4 coefficients can be reduced by choosing the input data which have the random v'/r' curve and 4 coefficients are estimated within 2-4% error, which may be noise level. So, it is recommended to operate the rudder randomly in sea trial or model test for the application of system identification technique.

  • PDF

A numerical solution to fluid-structure interaction of membrane structures under wind action

  • Sun, Fang-Jin;Gu, Ming
    • Wind and Structures
    • /
    • 제19권1호
    • /
    • pp.35-58
    • /
    • 2014
  • A numerical simultaneous solution involving a linear elastic model was applied to study the fluid-structure interaction (FSI) of membrane structures under wind actions, i.e., formulating the fluid-structure system with a single equation system and solving it simultaneously. The linear elastic model was applied to managing the data transfer at the fluid and structure interface. The monolithic equation of the FSI system was formulated by means of variational forms of equations for the fluid, structure and linear elastic model, and was solved by the Newton-Raphson method. Computation procedures of the proposed simultaneous solution are presented. It was applied to computation of flow around an elastic cylinder and a typical FSI problem to verify the validity and accuracy of the method. Then fluid-structure interaction analyses of a saddle membrane structure under wind actions for three typical cases were performed with the method. Wind pressure, wind-induced responses, displacement power spectra, aerodynamic damping and added mass of the membrane structure were computed and analyzed.

생수 및 정수기 소비지출에 대한 이변량 토빗 연립방정식 분석 (Simultaneous Equation Bivariate Tobit Analysis of Bottled Water and Water Purifier Consumption Expenditures)

  • 유승훈
    • 자원ㆍ환경경제연구
    • /
    • 제12권4호
    • /
    • pp.559-577
    • /
    • 2003
  • 상수원이 오염되고 수돗물 수질을 불신함에 따라 이에 대한 방어적 지출로서 생수 및 정수기에 대한 지출이 늘어나고 있다. 이러한 두 가지 지출자료를 분석하기 위해서는 세 가지 중요한 측면을 고려해야 한다. 즉, 지출에 있어서 영의 자료가 많이 관측되며, 두 가지 지출이 서로 상호종속적일 수 있고, 또 내생적으로 함께 결정될 수 있다. 따라서 본 논문에서는 이변량 토빗 연립방정식 분석을 통해 영의 관측치, 상호종속성, 내생성의 문제를 명시적으로 다루고자 한다. 1997년 서울에서 수집된 가구서베이 자료를 이용하여 두 가지 지출함수의 모수들을 추정한다. 분석결과, 두 지출간에 상호종속성이 발견되었으며, 한 가지 지출변수는 다른 지출함수에서 통계적으로 유의하였다. 따라서 본 연구에서 이용된 이변량 토빗 연립방정식 모형은 생수 및 정수기 소비지출 자료의 분석에 적합하다고 판단된다. 마지막으로 지출의 소득 탄력성 및 가구크기 탄력성 추정치도 제시한다.

  • PDF

연립방정식 모형의 계수조건 검정법 제안 (A Test of the Rank Conditions in the Simultaneous Equation Models)

  • 소선하;박유성;이동희
    • Communications for Statistical Applications and Methods
    • /
    • 제16권1호
    • /
    • pp.115-125
    • /
    • 2009
  • 경영.경제분야에서 사용되는 모형 가운데 연립방정식 모형은 모형 내에서 결정되는 내생변수와 모형 외부로부터 결정된 외생변수들로 구성된 M개의 방정식과 T개의 관찰치로 이루어진 회귀방정식체계이며, 모형에 대한 모수식별 및 유일해의 존재여부에 대한 결정방법으로 순서조건과 계수조건이 있다. 그러나 대부분 연립방정식 모형이 이들 조건을 만족한다는 가정하에서 모수들을 추정하기 때문에 추정값이 비효율적이거나, 유일한 모수 추정값이 존재하지 않는 경우가 이들 조건에 따라 발생할 수 있다. 본 연구에서는 순서조건을 만족한다는 가정 하에서 계수조건의 충족여부를 검정하기 위한 검정통계량을 새롭게 제시하고 이의 근사분포를 도출하였으며, 이와 함께 모의 실험을 통하여 제안한 검정통계량의 검정력을 살펴보았다.

Preconditioning technique for a simultaneous solution to wind-membrane interaction

  • Sun, Fang-jin;Gu, Ming
    • Wind and Structures
    • /
    • 제22권3호
    • /
    • pp.349-368
    • /
    • 2016
  • A preconditioning technique is presented for a simultaneous solution to wind-membrane interaction. In the simultaneous equations, a linear elastic model was employed to deal with the fluid-structure data transfer at the interface. A Lagrange multiplier was introduced to impose the specified boundary conditions at the interface and strongly coupled simultaneous equations are derived after space and time discretization. An initial linear elastic model preconditioner and modified one were derived by treating the linearized elastic model equation as a saddle point problem, respectively. Accordingly, initial and modified fluid-structure interaction (FSI) preconditioner for the simultaneous equations were derived based on the initial and modified linear elastic model preconditioners, respectively. Wind-membrane interaction analysis by the proposed preconditioners, for two and three dimensional membranous structures respectively, was performed. Comparison was made between the performance of initial and modified preconditioners by comparing parameters such as iteration numbers, relative residuals and convergence in FSI computation. The results show that the proposed preconditioning technique greatly improves calculation accuracy and efficiency. The priority of the modified FSI preconditioner is verified. The proposed preconditioning technique provides an efficient solution procedure and paves the way for practical application of simultaneous solution for wind-structure interaction computation.

연립방정식모형과 경로모형을 이용한 종합병원의 원가동인 분석 (Cost Driver Analysis in General Hospitals Using Simultaneous Equation Model and Path Model)

  • 양동현;이원식
    • 보건행정학회지
    • /
    • 제14권1호
    • /
    • pp.89-120
    • /
    • 2004
  • The purpose of this empirical study is to test hypotheses in order to identify the cost drivers that drive indirect costs in general hospitals in Korea. In various cases' studies, it has been suggested that overhead costs are driven by volume and complexity variables, how they are structurally related and how the cost impacts of these variables can be A unique feature of the research is the treatment of complexity as an endogenous variable. It is hypothesized that level of hospital complexity in terms of the number of services provided(i.e., “breath" complexity) and the intensity of individual estimated in practice. overhead services(ie., “depth" complexity) are simultaneous determined with the level of costs needed to support the complexity. Data used in this study were obtained from the Database of Korean Health Industry Development Institute, Health Insurance Review Agency and analyzed using simultaneous equation model, path model. The results found those volume and complexity variables are all statistically signi-ficance drivers of general hospital overhead costs. This study has documented that the level of service complexity is a significant determinant of hospital overhead costs, caution should be exercised in interpreting this as supportive of the cost accounting procedures associated with ABC. with ABC.

경제충격 시기의 한계소비성향 분석 - FIML 마코프-스위칭 모형 이용 (Marginal Propensity to Consume with Economic Shocks - FIML Markov-Switching Model Analysis)

  • 윤재호;이주형
    • 한국산학기술학회논문지
    • /
    • 제15권11호
    • /
    • pp.6565-6575
    • /
    • 2014
  • 본 논문에서 Hamilton의 마코프-스위칭 모형을 연립방정식으로 확장한 FIML 마코프-스위칭 모형을 제시해 보았다. 본 논문의 FIML 마코프-스위칭 모형을 LIML 마코프-스위칭 모형 등과 비교하면 LIML 마코프-스위칭 모형은 FIML 마코프-스위칭 모형의 특별한 경우이며 FIML 마코프-스위칭 모형은 연립방정식으로 확장된 일반화된 모형 형태를 띄게 된다. 본 논문의 FIML 마코프-스위칭 모형을 Campbell and Mankiw 소비함수에 적용해 본 결과, 2008년 부동산 거품 붕괴와 같은 경제충격 시기의 한계소비성향은 매우 민감도가 높아진다는 것을 알 수 있다.

시스템 검증법에 의한 조종성능(操縱性能) 해석(解析) (Maneuverability Analysis of a Ship by System Identification Technique)

  • 강창구;서상현;김재신
    • 대한조선학회지
    • /
    • 제21권4호
    • /
    • pp.10-20
    • /
    • 1984
  • When the hydrodynamic coefficients of the ship maneuvering equation are estimated by captive model test, it is difficult to take account of the scale effect between model and full scale ship. This scale effect problem can be overcome by processing the sea trial data with system identification. Extended Kalman filter is used as a system identification technique for the modification of the simulation equation as well as the estimation of hydrodynamic coefficients The phenomena of simultaneous drifting of linear coefficients occur. It is confirmed that two coefficients in each pair-$(Y_v',\;Y_r'-m'u'),\;(N_v',\;N_r')$-are simultaneously drifting and all 4 coefficients are drifting together. Particularly simultaneous drifting and 2 coefficients in each pair is more significant. It is also shown that the simultaneous drifting of 4 coefficients can be reduced by choosing the input data which have the random v'/r' curve and 4 coefficients are estimated within $2{\sim}4%$ error, which may be noise level. So, it is recommended to operate the rudder randomly in sea trial or model test for the application of system identification technique.

  • PDF

가정 내 쇼핑채널 이용비중 및 이용다양성에 관한 연구 (A Study on the Share and the Variety of In-Home Shopping Channel - Simultaneous Equation Model with Selectivity -)

  • 주영혁;양석준
    • 한국유통학회지:유통연구
    • /
    • 제11권3호
    • /
    • pp.103-125
    • /
    • 2006
  • 본 연구에서는 최근 물류시스템과 통신매체의 급격한 발달로 인하여 보편화된 가정 내 쇼핑채널을 연구함에 있어서 새로운 접근방법이 필요함을 제시하고 있다. 가정 내 쇼핑채널 각각에 구매의도에 대한 영향요인을 검토하는 채널중심 연구는 가정 내 쇼핑채널이 보편화된 현재에는 큰 의미를 가지기 어렵다고 볼 수 있다. 본 연구에서는 고객중심 채널연구의 필요성을 제기하고 가정 내 쇼핑채널 이용비중과 이용다양성에 대한 고객특성과 쇼핑특성의 영향을 고객 중심적으로 검토하였다. 표본의 선택성을 고려하고 종속변수 간 인과관계를 모델에 반영하기 위하여 선택성을 가진 동시방정식 모델을 통하여 실증분석을 수행하였다. 연구결과 첫째로 가정 내 쇼핑채널 이용비중과 이용다양성은 서로 영향이 없는 것으로 나타나고 있으며, 둘째로 점포형 쇼핑채널 중에서 특히 백화점 이용이 증가할수록 가정 내 쇼핑채널 이용비중은 감소하는 것으로 나타나고 있으며, 셋째로 고객특성 및 쇼핑특성은 가정 내 쇼핑채널 이용다양성에 영향을 미치지 않는 것으로 나타나고 있다.

  • PDF

모형체계의 안정성 진단 (Diagnosing the stability for the model of a system of equations)

  • 김태호;김영권;한정혜
    • 응용통계연구
    • /
    • 제11권1호
    • /
    • pp.65-81
    • /
    • 1998
  • 많은 실증분석에 사용되고 있는 연립방정식모형은 연구대상분야의 구조를 더욱 현실에 가깝게 표현하고 또 상세한 분석을 위해 점차 복잡해지고 대형화되어 가는 추세다. 그러나 이러한 다중방정식체계의 설정시, 각 회귀방정식이 결합되어 동시에 추정될 때 발생할 수도 있는 모형체계의 구조적 불안정성으로 인해 추정된 모형의 사용 및 그에 따른 분석은 오류를 가져올 수 있다. 특히 시뮬레이션 수행이 무의미해질 가능성이 있음에도 연립방정식모형을 사용하는 대부분의 연구들이 이러한 모형의 구조적 안정성문제를 간과하고 있는 실정이다. 따라서 본 연구에서는 동태적 관점에서 모형체계의 안정성 진단을 위한 조건을 제시하여 보고, 실제의 연립방정식모형을 예로 들어 적용시켜 본 후 그 결과가 모형의 구조적 특징에 관해 어떠한 유용한 정보를 제공하여 주는가를 추가로 분석하여 보았다.

  • PDF